Salivary-based Bone Loss Marker Detection Platform for Point-of-care Screening - Phase II Study

Salivary-based Bone Loss Marker Detection Platform for Point-of-care Screening - Phase II Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02315248
Enrollment
197
Registered
2014-12-11
Start date
2014-12-31
Completion date
2016-08-31
Last updated
2017-02-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Osteoporosis

Keywords

bone density

Brief summary

The purpose of this study is to validate a human saliva sample analyzer technique designed to screen for low bone density and osteoporosis. The analyzer technique is meant to be a simple, noninvasive, easy-to-use, cost-effective, and routine means of diagnosing bone turnover using a point-of-care device that monitors salivary markers of bone turnover in a screening patient population that is at risk for low bone density or osteoporosis.

Detailed description

Primary objective: To validate the performance of human saliva sample analyzer LFA technique against bone density as measured by quantitative computed tomography (QCT). Secondary objective: To validate the performance of human saliva sample analyzer LFA technique against salivary ELISA method (gold standard). Number of sites: Single site at the University of Mississippi Medical Center The purpose of this prospective Phase II observational study is to further refine a proprietary device and test it in a screening population composed of women 50 years of age or older who are at risk for low bone density or osteoporosis (N=200). After screening for inclusion and exclusion criteria and obtaining informed consent, participants will provide a salivary sample and will undergo quantitative computed tomography (QCT) at the same visit (Visit 1, Day 0). No additional visits are planned. Bone mineral density (BMD) will be measured by diagnostic radiologists using QCT techniques and serve as the gold standard for the study. Salivary samples will be analyzed by a lab at UMMC for concentrations of osteocalcin (OC) and deoxypyridinoline (DPD) using enzyme-linked immunosorbent assay (ELISA) techniques, while blinded to BMD measurements. De-identified and coded salivary sample will be shipped to IOS who will measure concentrations of OC and DPD using lateral flow assay (LFA), while blinded to BMD measurements.

Interventions

RADIATIONQuantitative computed tomography scan for bone density analysis

A low radiation dose quantitative computed tomography (QCT) of the spine (L1 and L2) and the hips will be performed to measure bone density in the spine and hips.

Sponsors

National Institute of Dental and Craniofacial Research (NIDCR)
CollaboratorNIH
University of Mississippi Medical Center
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
50 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Female ≥50 years of age and referred for standard of care screening mammogram. * Ability to provide salivary samples. * Ability to lie flat on the CT scanner. * Ability and willingness to provide signed and dated informed consent.

Exclusion criteria

* Any known bone metabolism disorder (other than osteoporosis or low bone density) including sickle cell disease, current neoplastic disease, metastatic disease or any neoplastic disease involving the bones (including leukemia), or Paget's disease. * Body weight exceeds the weight limit (\>400lbs) of the CT table. * Vulnerable subjects including pregnant women and prisoners. * Subjects who have had prior QCT imaging to measure bone density.

Design outcomes

Primary

MeasureTime frameDescription
Validation of human saliva sample analyzer LFA technique against measured bone density20 monthsTo validate the performance of human saliva sample analyzer LFA technique against bone density as measured by quantitative computed tomography (QCT).

Secondary

MeasureTime frameDescription
Validation of human saliva sample analyzer LFA technique against ELISA (gold standard)20 monthsTo validate the performance of human saliva sample analyzer LFA technique against salivary ELISA method (gold standard).