Skip to content

Removal of Cytokines During Extracorporeal Circulation in Cardiac Surgery

Reduction of Inflammation Reaction to Extracorporeal Circulation in Cardiac Surgery by Interleukin Dialysis

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02297334
Enrollment
40
Registered
2014-11-21
Start date
2013-09-30
Completion date
2017-08-31
Last updated
2017-08-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease, Heart Valve Diseases

Keywords

CytoSorb(TM), cytokines, inflammation, cardiac surgery, extracorporeal bypass

Brief summary

The aim of this study is to prove that using a CytoSorb(TM) filter in the cardiopulmonary circuit attenuates the inflammatory response to extracorporeal circulation in patients undergoing cardiac surgery. The hypothesis is that removing cytokines from patients' blood by the CytoSorb device significantly improves circulation and outcome in patients undergoing on-pump cardiac surgery.

Detailed description

Cardiac surgery with cardiopulmonary bypass (CPB) induces an inflammatory response due to contact of patients' blood with foreign surfaces like tubes or the oxygenator, ischemic-reperfusion injury and surgical trauma. Inflammation is modulated by cytokines, especially, interleukins. The extent of cytokine release is further related to the duration of bypass and the amount of operating field suction. This results in a systemic inflammatory response syndrome (SIRS) with the risk of multiple organ dysfunction (MOD). Also in patients treated with extracorporeal membrane oxygenation (ECMO) an activation of the inflammation system is seen and accompanied with an increase of cytokine levels. The cytokine concentration correlates with the severity of the immune reaction and can be a predictor of the outcome of the patient. As severe SIRS and MOD significantly increase mortality, the attenuation of the inflammatory response is supposed to reduce morbidity and mortality after cardiac surgery. For adult cardiac surgery and patients who are treated with an extracorporal assist device, a tool for cytokine elimination and attenuation of the inflammatory response seems to be beneficial. In our study we are going to investigate if the use of the CytoSorb device can improve the outcome of patients undergoing elective coronar artery bypass and heart valve surgery.

Interventions

In 20 patients the CytoSorb device will be installed into the extra corporeal circuit. A blood flow of 400ml/min is provided by an roller pump of the heart lung machine in a parallel stream to the main circulation.

Sponsors

Universitätsklinikum Hamburg-Eppendorf
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* undergoing elective coronar bypass AND heart valve surgery * expected duration of bypass more than 120 min

Exclusion criteria

* age under 18 years of age * pregnancy * medication that interacts with the immune system (e.g. steroids, immune suppressors) * patients with diagnosed immunodeficiency (e.g. HIV/AIDS) * heparin induced thrombocytopenia type II * patients that decline participation

Design outcomes

Primary

MeasureTime frameDescription
Change of levels of cytokines during procedure compared to baseline1) 5 minutes before bypass 2) 2 hours after begin of bypass, 3) at the end of bypass, approximately 3 hours after begin of bypass, 4) 6 hours after bypass 5) 24 hours after bypassparameters to be measured are: interleukin (IL) 1, interleukin 6, interleukin 8, interleukin 10, tumor necrosis factor-alpha

Secondary

MeasureTime frameDescription
Change of hemodynamic parameters during procedure compared to baseline1) 5 kinutes before bypass 2) 2 hours after begin of bypass, 3) at the end of bypass, approximately 3 hours after begin of bypass, 4) 6 hours after bypass 5) 24 hours after bypassHemodynamic and respiratory parameters such as mean arterial pressure, heart rate and peripheral oxygen saturation are recorded. In addition thermodilution parameters (stroke volume variability, global end diastole volume, extravascular lung water index, cardiac index, systemic vascular resistance) are measured. Volume and catecholamine therapies are managed by an algorithm based on thermodilution parameters.
Thromboelastometryat the end of bypass, approximately 3 hours after begin of surgeryAt the end of extracorporeal circulation a rotation thromboelastometry analysis is performed and the clotting time (CT), the clot formation time (CFT), the maximum clot firmness (MCF) in In- and Ex-Tem and the MCF in Fib-Tem are measured. Based on an institutional algorithm the coagulation therapy is performed according to the results of the thromboelastometry.
Change of cognitive and emotional state in comparison to condition before surgery1)one day before surgery 2) 24 hours after bypassTo evaluate, if the use of the cytokine-filter has any influence on cognitive function or the emotional state, the patients perform the mini-mental state examination and answer questions of the Geriatric Depression Scale questionaire. Results before and 24 hours after end of bypass are recorded.

Other

MeasureTime frameDescription
Intensive care durationsafter discharge from ICU, approximately 24 hours after admissionAfter discharge from ICU the duration of stay and postoperative ventilation is recorded.
Amount of administered fluidsat the end of surgery, approximately 3 hours after begin of surgeryThe amount of fluids administered during operation is recorded.
complication and adverse events24 hours after admission to ICUAny complications or adverse events, like death, bleeding, rethoracotomy or malignant arrhythmias are recorded.
Amount of administered catecholamines.at the end of surgery, approximately 3 hours after begin of surgeryThe amount of catecholamines administered during operation is recorded.
Amount of administered catecholaminesafter discharge from ICU, approximately 24 hours after surgeryThe amount of catecholamines administered during operation is recorded.
Change of a set of general laboratory parameters during procedure1) 5 minutes before bypass 2) 2 hours after begin of bypass, 3) at the end of bypass, approximately 3 hours after begin of surgery 4) 6 hours after bypass 5) 24 hours after bypassIn laboratory tests we measure the whole blood count (red blood cells, white blood cells, thrombocytes), C-reactive protein, liver enzymes (GOT, GPT), kidney parameters (creatinine, glomerular filtration rate) and electrolytes (sodium, potassium, calcium) are measured.

Countries

Germany

Outcome results

None listed