Skip to content

Intubation During Resuscitation

Comparison of Four Types of Laryngoscope for Tracheal Intubation During Chest Compressions

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02277951
Acronym
IDR
Enrollment
141
Registered
2014-10-29
Start date
2014-05-31
Completion date
2014-07-31
Last updated
2014-10-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiopulmonary Resuscitation, Intubation

Brief summary

The aim of the study was to compare time and success rates of four intubation devices ( in a cardiopulmonary scenario with uninterrupted chest compressions with a standardized manikin model. The investigators hypothesized that fiberoscope laryngoscopes may improve success rates.

Detailed description

Devices using in study: The Bonfils Intubation Fibrescope (BONFILS)(KARL STORZ Endovision, Inc., Charlton, MA, USA), The Video Rigid Flexing Laryngoscope (RIFL)( AI Medical Devices, Inc., Williamston, MI, USA), The C-MAC® S Video Laryngoscope Blade Mac#3(C-MAC®S) (KARL STORZ Endovision, Inc., Charlton, MA, USA) The Macintosh Laryngoscope Blade no. 3 (MAC) (LifeLine Medical, Inc., Brooksville, FL, USA).

Interventions

Effectiveness and time to successful intubation will be measured.

DEVICEThe Video Rigid Flexing Laryngoscope

Effectiveness and time to successful intubation will be measured.

DEVICEThe C-MAC® S Video Laryngoscope

Effectiveness and time to successful intubation will be measured.

Effectiveness and time to successful intubation will be measured.

Sponsors

International Institute of Rescue Research and Education
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

* experienced emergency personnel: nurses, paramedics

Exclusion criteria

* no experience in out-of-hospital emergency medicine

Design outcomes

Primary

MeasureTime frameDescription
Time to successful intubationSubjects complete study in 1 dayThe devices to be compared include (1) The Bonfils Intubation Fibrescope , (2) the Video Rigid Flexing Laryngoscope, (3) the C-MAC® S Video Laryngoscope, (4) the Macintosh Laryngoscope. Successful intubation will be measured in the seconds from insertion of an intubation device to the first manual ventilation of the mannequin's lungs.
Success rate of ETISubjects complete study in 1 dayThe devices to be compared include (1) The Bonfils Intubation Fibrescope , (2) the Video Rigid Flexing Laryngoscope, (3) the C-MAC® S Video Laryngoscope, (4) the Macintosh Laryngoscope. Successful intubation will be measured in the seconds from insertion of an intubation device to the first manual ventilation of the mannequin's lungs.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026