Comparison of the Skin Conductance Values and Patient Pain Scores During Minor Procedures in the ICU

Comparison of the Skin Conductance Values and Patient Pain Scores During Minor Procedures in the ICU

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02276703
Enrollment
30
Registered
2014-10-28
Start date
2014-10-31
Completion date
2017-06-30
Last updated
2017-09-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pain

Brief summary

Pain in hospitalized patients has received increasing attention, however due to its subjective nature, it has defied objective, quantitative measurements. If a patient is able to communicate, pain may be assessed using standardized sentences, visual analog scales (VAS) or plain numeric scales. When a patient is unable to communicate, a method that would allow the caregiver to continuously monitor patients' pain and alert the provider that the patient may be in pain would be quite useful. The Pain Monitor uses a novel measurement technique of analyzing changes in skin conductance that can be used in patients who are unable to provide a subjective pain score. This study will compare the relationship between the measurements taken by the PainMonitor and pain scores given by communicative patients to evaluate the safety and efficacy of this monitor during planned, routine procedures.

Detailed description

Although pain must be assessed to be treated, it has been challenging to obtain consistent, objective, and quantifiable measurements. The best methods currently available are subjective scales communicated by the patient such as standardized sentences, visual analog scales (VAS), or plain numeric scales. When a patient is unable to communicate, methods used to monitor pain are inadequate. A device that provides an objective assessment of pain in these patients would alert the patient's caregivers that the patient may be in pain and analgesic treatment is indicated. Various methods (Evans et al, 2013; Kantor, 2014; Isnardon, 2013) have been proposed to monitor patients' reactions to nociceptive stimulation such as: * changes in heart rate or blood pressure * changes in microcirculation * pupillometry * EEG * Auditory or somatosensory evoked potentials All of these methods have been found lacking, mostly due to a lack of specificity for pain. Pupillometry is not suitable for long periods of measurement and is sensitive to concomitant treatment (e.g. opioids). Galvanometry has the potential to provide specific information related to pain in patients who are unable to communicate. Since sweat glands are the only organs controlled solely by the sympathetic nervous system, there is a reasonable chance that the use of galvanometry can provide a reliable means of assessing pain. There are numerous papers on this topic; searching in PUBmed on the key words pain and skin conductance results in more than 250 papers (selected references are included in the list below). The PainMonitor system uses galvanometry to monitor changes in skin conductance responses per sec mirroring the number of bursts in the skin sympathetic nerves. This creates a warning for caregivers to assess the potential that the patient is in pain.

Interventions

monitors skin conductance values

Sponsors

Med-Storm Innovation
CollaboratorUNKNOWN
Hopital Foch
CollaboratorOTHER
Milton S. Hershey Medical Center
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 89 Years
Healthy volunteers
No

Inclusion criteria

* Patients between the ages of 18-89 years (inclusive), in an adult ICU * Patients admitted to the ICU who are able to communicate their pain and anxiety using a VAS * Patients must be cooperative and not agitated. * Planned to have a potentially painful procedure

Exclusion criteria

* Diagnosed neuropathic disease * Use of neostigmine within the past 3 hours * Use of regional anesthesia at the extremity where the device electrodes are placed

Design outcomes

Primary

MeasureTime frameDescription
Sensitivity and specificity with a confidence interval1 yearSensitivity and specificity with a confidence interval \> 80 % when skin conductance responses per sec are \> 0.13 and VAS is equal to or greater than 30 mm. This end point will be reached by 100 patients with at least 10 discrete measurements for each patient.

Countries

France, United States

Outcome results

None listed