Stage 3 Fontan Operation Liver Ultrasound Study

Noninvasive Detection of Liver Injury Immediately Following the Fontan Operation: the Role of Ultrasound-Based Elastography

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02269709
Enrollment
21
Registered
2014-10-21
Start date
2014-11-30
Completion date
2016-07-31
Last updated
2018-01-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fontan Operation

Brief summary

The purpose of this study is to compare the liver stiffness, which can be caused by congestion and fibrosis in pediatric patients before and after a Fontan heart operation. A new form of ultrasound elastography (Acoustic Radiation Force Impulse, or ARFI) will measure liver stiffness.

Detailed description

The Fontan repair for single ventricle congenital heart lesions consists of three stages. This surgery has enable pediatric patients who have the repair to live into adulthood. Stage 3 of the surgery introduces immediate congestion of blood in the liver by increasing central venous pressure (CVP). CVP is the blood pressure within the vena cava, a major blood vessel in the body. Many patients later develop progressive liver fibrosis (stiffness) possibly as a result of increased blood pressure. Liver stiffness is increased both by congestion and fibrosis. Liver fibrosis has significant health risks and may complicate the patient's future healthcare. There are no established, noninvasive means of detecting the liver fibrosis until it becomes severe. Acoustic radiation force impulse (ARFI) elastography, an ultrasound technique, can measure the stiffness of the liver safely from outside the body. The investigators hypothesize that liver stiffness will be increased by stage 3 of the Fontan operation due to onset of liver congestion. Using ARFI, the investigators will measure liver stiffness before and immediately after stage 3 of the Fontan operation, when congestion of blood is likely the only contributor to any change in liver stiffness. The investigators will follow the trend of liver stiffness at six months by repeating the ARFI imaging.

Interventions

This research scan uses acoustic radiation force impulse (ARFI) shear wave velocity imaging (SVI). This is a new ultrasound technology in which unique sound waves create the images/pictures of the liver beng examined/scanned. This ultrasound scan will take approximately 10 minutes to complete.

Sponsors

University of Michigan
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
No minimum to 17 Years
Healthy volunteers
No

Inclusion criteria

* Pediatric patients ages 0-17 * Patients presenting to the University of Michigan for evaluation just before undergoing stage 3 of the Fontan operation

Exclusion criteria

* Patients over the age of 17 * Patients who have chronic liver disease (elevation of ALT, AST, or Bilirubin greater than two times the upper limits of normal \>4 weeks) * Patients who have evidence of liver enlargement or nodularity on prior ultrasound imaging * Patients who have a history of portal vein or hepatic vein thrombosis * Patients (parents) who are unwilling to read and sign the informed consent document

Design outcomes

Primary

MeasureTime frameDescription
Shear Wave Speed (Liver Stiffness)0-6 monthsARFI shear wave speed measurements were done on the right lobe of the liver. Measurement units are m/s (meters per second). A total of 8 measurements were performed on each subject at each time point.The 8 values were performed on each subject and averaged.

Secondary

MeasureTime frameDescription
IVC PressureBaseline and Follow Up Number 1 (approximately 24 -72 hours later)Blood pressure in the IVC, the interior vena cava, was measured from a central line placed for patient care.

Countries

United States

Participant flow

Participants by arm

ArmCount
ARFI Ultrasound
Subjects were pediatric patients who had undergone a Fontan operation. Subjects underwent an ultrasound before and after the Fontan operation. The ultrasound scan used acoustic radiation force impulse (ARFI) shear wave velocity imaging (SVI). This is a non-invasive scan that uses sound waves to create images of the liver and measure the stiffness of the tissue.
18
Total18

Withdrawals & dropouts

PeriodReasonFG000
Follow-up #1 (24-72 Hours Post-surgery)Lost to Follow-up1
Six Month Follow-upLost to Follow-up12
Time of EnrollmentWithdrawal by Subject3

Baseline characteristics

CharacteristicARFI Ultrasound
Age by Sex
Age of Female Subjects
33 Months
Age by Sex
Age of Male Subjects
34 Months
Age, Continuous33.5 Months
STANDARD_DEVIATION 10.5
Sex: Female, Male
Female
6 Participants
Sex: Female, Male
Male
12 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 18
other
Total, other adverse events
0 / 18
serious
Total, serious adverse events
0 / 18

Outcome results

Primary

Shear Wave Speed (Liver Stiffness)

ARFI shear wave speed measurements were done on the right lobe of the liver. Measurement units are m/s (meters per second). A total of 8 measurements were performed on each subject at each time point.The 8 values were performed on each subject and averaged.

Time frame: 0-6 months

Population: As shown in the participant flow, data was not captured for follow up time points 1 and 2 for 1 participant. At time point 3 data is only available for 5 participants.

ArmMeasureGroupValue (MEAN)Dispersion
ARFI UltrasoundShear Wave Speed (Liver Stiffness)Liver Stiffness at baseline1.18 meters per secondStandard Deviation 0.29
ARFI UltrasoundShear Wave Speed (Liver Stiffness)Liver Stiffness follow-up tim1 (24-72 hours later)2.28 meters per secondStandard Deviation 0.31
ARFI UltrasoundShear Wave Speed (Liver Stiffness)Liver Stiffness follow-up time 2 (7 days later)2.22 meters per secondStandard Deviation 0.38
ARFI UltrasoundShear Wave Speed (Liver Stiffness)Liver stiffness follow-up time 3 (6 months)2.08 meters per secondStandard Deviation 0.24
Comparison: Comparison of Baseline and Follow-up #1p-value: <0.0001Mixed Models Analysis
Comparison: Comparison of Baseline vs. Follow up #2p-value: <0.0001Mixed Models Analysis
Comparison: Comparison of Baseline vs. Follow-up #3p-value: <0.0001Mixed Models Analysis
Secondary

IVC Pressure

Blood pressure in the IVC, the interior vena cava, was measured from a central line placed for patient care.

Time frame: Baseline and Follow Up Number 1 (approximately 24 -72 hours later)

Population: Subjects who had undergone the Fontan operation and who had a central line placed. Blood pressure values were obtained from chart review.

ArmMeasureGroupValue (MEAN)Dispersion
ARFI UltrasoundIVC PressureIVC pressure before Fontan operation7.2 mmHgStandard Error 2.6
ARFI UltrasoundIVC PressureIVC pressure after Fontan operation (24-72 hours)16.44 mmHgStandard Error 3.3