Skip to content

Gonadal Radiation Exposure and Risk Secondary to Fluoroscopic Imaging During Trauma Surgery

A Descriptive Cohort Analysis of Gonadal Radiation Exposure and Risk Secondary to Fluoroscopic Imaging During Trauma Surgery About the Pelvis and Femur

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02267330
Enrollment
135
Registered
2014-10-17
Start date
2012-02-29
Completion date
2015-05-31
Last updated
2023-11-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acetabular Fractures, Femur Fractures, Hip Fractures, Pelvic Injuries

Keywords

Gonadal Radiation Exposure, Fluoroscopic Imaging, Trauma Surgery, Pelvis fractures, Femur fractures

Brief summary

The aim of this cohort study is to precisely measure patients' exposure to gonadal radiation during orthopaedic trauma surgery involving the acetabulum, pelvis, hip, and femur, and to apply these findings to a previously described and validated formula to determine the increased risk of future adverse health effects to the reproductive organs. The investigators null hypothesis is standard of care use of x-ray fluoroscopy during treatment of pelvis, hip, and femur fractures will not expose patients to a significant gonadal radiation load. Analysis of patients' intraoperative radiation doses by means of a previously validated formula will not display a significantly increased risk of adverse health events in the reproductive organs.

Detailed description

In the United States, physicians treat more than one and a half million fractures of the pelvis, hip, and femur each year.1-3 Exposure of patients to ionizing radiation during both diagnosis and treatment of these injuries is an unfortunate reality in the standard of care. Regulations put forth by the US National Radiation Committee (USNRC) include limiting maximum radiation exposure, above background levels, to individual members of the public to less than 1 millisievert (mSv) per year.4 While no current recommendations exist regarding medical exposure in patients, physicians are expected to display judicious practice of both diagnostic and therapeutic procedures during which patients are exposed to ionizing radiation.4 Nevertheless, patients whom undergo trauma activation are exposed to radiation levels that are significant and possibly excessive at 25 to 32 mSv during admission.5,6 The probability that radiation exposure may be reduced is supported by previous studies, which have established that only 60% of surgical trainees take into account the risks of radiation to a patient and that training on intraoperative fluoroscopy technique can decrease patient exposure by more than 50%, while maintaining an equivalent result.7,8 Few previous studies have addressed patient exposure to radiation during operative treatment of orthopaedic injuries.5,9,10 Previous research documenting radiation dose during surgeries of the pelvis and femur have used fluoroscope-calculated dose area product (DAP), which is less accurate than the direct dosimetry proposed in our study.11-13 Furthermore, prior studies have inappropriately determined stochastic risk through the linear no-threshold (LNT) model, which according to the USNRC, provides limited statistical power for epidemiologically based conclusions and overestimates risk at comparatively low doses such as those seen in trauma patients.14,15 Using a more accurate and previously validated model, the stochastic effects of exposure to the reproductive organs can be calculated at a more precise level than provided by previous studies.15,16 The investigators hope this research would allow the orthopaedic community to more accurately express the risks of intraoperative radiation to the patient, while supporting improved training on fluoroscopic technique and promoting the development of less fluoroscopic dependent fixation techniques.

Interventions

PROCEDUREExposure Recording

Patient undergoing fracture surgery will have radiation exposure recorded

Sponsors

University of Utah
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 88 Years
Healthy volunteers
No

Inclusion criteria

* Patients over the age of 18 Patients with: * Hip fractures (femoral neck fractures, intertrochanteric fractures) * Femur fractures (subtrochanteric fractures, femoral shaft fractures) * Acetabular fractures * Posterior pelvic ring injuries Patients requiring surgical fixation of their injuries per standard of care

Exclusion criteria

* Any patients under the age of 18 * Any patient not fluent in English. * Hip fracture undergoing prosthetic replacement

Design outcomes

Primary

MeasureTime frameDescription
Gonadal radiation doseDuring surgical interventionThe primary outcome variable will be patient gonadal radiation dose documented through dosimeter application and analysis during standard of care operative intervention.

Secondary

MeasureTime frameDescription
Fluoroscope-calculated dose.During surgical interventionThe investigators will document fluoroscope-calculated dose.

Outcome results

None listed