Skip to content

Diaphragm Electrical Activity of Preterm Infants on nCPAP Versus NIHFV

Effect of Nasal Continuous Positive Airway Pressure (nCPAP) Versus Non-Invasive High Frequency Ventilation (NIHFV) on the Diaphragm Electrical Activity in Very Low Birth Weight Preterm Infants

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02267018
Enrollment
20
Registered
2014-10-17
Start date
2016-08-31
Completion date
2020-06-30
Last updated
2021-03-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Respiratory Distress Syndrome, Newborn

Keywords

nCPAP, High-Frequency Oscillator Ventilation, Diaphragm Electrical Activity

Brief summary

Preterm babies have immature lungs and frequent pauses in their breathing which often necessitates breathing support. Nasal Continuous Positive Airway Pressure (nCPAP) is one of the most commonly used tools, but does not always provide enough support. A new option is non-invasive high frequency ventilation (NIHFV), which gently shakes the lungs to help with gas exchange and may decrease a baby's work of breathing. The investigators plan to study very low birth weight preterm babies who are generally well but require some support with their breathing. By inserting a special feeding tube with sensors into the stomach, the investigators can measure the electrical activity of the diaphragm (EAdi), which is an important muscle for breathing. By analyzing EAdi in babies receiving either nCPAP or NIHFV, the investigators will be able to measure and compare how each method of support affects a baby's breathing. This important study will help us determine the most appropriate breathing support for preterm babies.

Detailed description

Continuous Positive Airway Pressure is one of the most researched and accepted methods of delivering NIV to term and preterm infants. Non-invasive high frequency ventilation is a relatively new method of delivering NIV respiratory support in preterm infants. Preliminary studies suggest superiority over CPAP, and NIHFV is being increasingly utilized in clinical practice in an attempt to prevent intubation and minimize ventilation-induced lung injury in preterm infants. However, little is known about its mechanism of action and its effect on respiratory mechanics in the newborn. The objective of this study is to compare the effects of non-invasive ventilation (NIV) delivered by nasal Continuous Positive Airway Pressure (nCPAP) versus Non-Invasive High Frequency Ventilation (NIHFV) on respiratory pattern as assessed by the electrical activity of the diaphragm (EAdi) in very low birth weight (VLBW) preterm infants. We hypothesize that in VLBW preterm infants with relative pulmonary insufficiency, NIHFV will reduce respiratory drive and improve ventilation, subsequently resulting in decreased patient diaphragm energy expenditure. This would be demonstrated by decreased neural respiratory rates and/or decreased peak electrical activity of the diaphragm while breathing on NIHFV compared to nCPAP. Clinicians are seeking alternative methods for providing non-invasive respiratory support to preterm infants. NIHFV is a relatively new modality that is being increasingly utilized in clinical practice but has not been well studied. This study will help us determine how non-invasive high frequency ventilation (NIHFV) affects breathing in preterm infants, as compared to the more traditional modality of nasal CPAP. Therefore, clinicians will not only be able to better understand how NIHFV works, but also utilize this information to decide on the most appropriate respiratory support modality for preterm patients

Interventions

This ventilator is capable of providing both nCPAP and NIHFV support.

Sponsors

Sunnybrook Health Sciences Centre
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
2 Days to 60 Days
Healthy volunteers
No

Inclusion criteria

* Clinically stable preterm infants with birth weights ≤1500g admitted to the neonatal intensive care unit (NICU) at Sunnybrook Health Sciences Centre or BC Women's and Children's Hospital. * Patient's on nasal continuous positive airway pressure of 6 to 8 cmH20 support for at least 48 hours, treated with methylxanthines for apnea of prematurity and requiring 25-40% of oxygen.

Exclusion criteria

* infants with congenital anomalies of the gastrointestinal tract, phrenic nerve damage, diaphragmatic paralysis, esophageal perforation; * infants with congenital or acquired neurological deficit (including significant intraventricular hemorrhage \>Grade II) \[27\], neonatal seizure; * infants with significant congenital heart disease (including symptomatic PDA); * infant with congenital anomalies of the diaphragm; * infant with congenital anomalies of the respiratory tracts (e.g. Congenital Cystic Adenomatoid Malformation (CCAM)) infants requiring ongoing treatment for sepsis, necrotizing enterocolitis (NEC), antibiotics for lung infections, narcotic analgesics, or gastric motility agents will be excluded. * infants on nasal CPAP and requiring more than 40% oxygen will be excluded from the study. * infants with significant gastric residuals and vomiting, infants with facial anomalies, infants with pneumothorax or pneumomediastinum, and infants in the immediate postoperative period will be excluded.

Design outcomes

Primary

MeasureTime frameDescription
The primary outcome will be the difference in the peak electrical activity of the diaphragm between nCPAP and NIHFV.4 hoursMeasured by the electrical activity of the diaphragm between respiratory support modes (nCPAP and NIHFV).

Secondary

MeasureTime frameDescription
Difference in neural respiratory rate.4 hoursMeasured by the electrical activity of the diaphragm between respiratory support modes (nCPAP and NIHFV).
Difference in neural inspiratory time.4 hoursMeasured by the electrical activity of the diaphragm between respiratory support modes (nCPAP and NIHFV).
Difference in diaphragm energy expenditure.4 hoursMeasured by the electrical activity of the diaphragm between respiratory support modes (nCPAP and NIHFV).
Difference in transcutaneous pCO2.4 hoursAs read from transcutaneous pCO2 monitor
Number of apnea episodes.4 hoursPauses in electrical activity of the diaphragm of greater than 5 seconds and greater than 15 seconds

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026