Magnetic Resonance Elastography of Cardiac Transplant Rejection

Magnetic Resonance Elastography of Cardiac Transplant Rejection

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02266914
Enrollment
9
Registered
2014-10-17
Start date
2014-01-27
Completion date
2017-12-01
Last updated
2019-05-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Graft Rejection

Brief summary

Magnetic Resonance Elastography (MRE) for cardiac transplant patients.

Detailed description

Patient will undergo MRE beginning 4-8 weeks post transplant, then with each scheduled cardiac biopsy through 7-8 months post transplant. Results of the MRE will be compared against results of the cardiac biopsy to determine if the non-invasive MRE can predict cardiac transplant rejection.

Interventions

DEVICEMagnetic Resonance Elastography driver

A driver is required for MRE. The driver utilizes sound waves to produce vibrations. Images of these vibrations are captured with Magnetic Resonance scanner to produce images that indicate stiffness in an organ.

Sponsors

Ohio State University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients must have undergone cardiac transplantation at the Ohio State University Ross Heart Hospital. * Patients must be able to lie flat on their back in the scanner for up to 60 minutes * Patient must be able to hold their breath for up to 15 seconds at a time.

Exclusion criteria

* Patients who are claustrophobic * Patients who are pregnant, due to potential risks to the fetus. * Patients with any unapproved, non-MRI safe metal/devices in their bodies.

Design outcomes

Primary

MeasureTime frameDescription
Cardiac Stiffness With Magnetic Resonance Elastography (MRE)24-48 hoursMRE scans will be performed within 24-48 hours of standard of care cardiac biopsies for patients who have undergone cardiac transplant at The Ohio State University Ross Heart Hospital. Stiffness results from the MRE will be compared to histopathology from the cardiac biopsy to determine if the completely non-invasive MRE can successfully predict transplant rejection.

Countries

United States

Participant flow

Recruitment details

Recruitment period: January 27, 2014 to December 7, 2014 (approximately 1 year) at The Ohio State University Wexner Medical Center.

Participants by arm

ArmCount
Cardiac Transplant Patients
Patients who have received a cardiac transplant at The Ohio State University Ross Heart Hospital will undergo Magnetic Resonance Elastography (MRE) (using a Magnetic Resonance Elastography driver) within 24-48 hours of standard of care biopsy. Results of both will be compared to determine if MRE can successfully predict cardiac transplant rejection. Magnetic Resonance Elastography driver: A driver is required for MRE. The driver utilizes sound waves to produce vibrations. Images of these vibrations are captured with Magnetic Resonance scanner to produce images that indicate stiffness in an organ.
9
Total9

Baseline characteristics

CharacteristicCardiac Transplant Patients
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
1 Participants
Age, Categorical
Between 18 and 65 years
8 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
1 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
8 Participants
Sex: Female, Male
Female
3 Participants
Sex: Female, Male
Male
6 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
1 / 9
other
Total, other adverse events
0 / 9
serious
Total, serious adverse events
0 / 9

Outcome results

Primary

Cardiac Stiffness With Magnetic Resonance Elastography (MRE)

MRE scans will be performed within 24-48 hours of standard of care cardiac biopsies for patients who have undergone cardiac transplant at The Ohio State University Ross Heart Hospital. Stiffness results from the MRE will be compared to histopathology from the cardiac biopsy to determine if the completely non-invasive MRE can successfully predict transplant rejection.

Time frame: 24-48 hours

Population: Data were not collected due to study termination.

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026