Skip to content

Cochlear Implants for Adults With Single-sided Deafness

Cochlear Implantation for Single-Sided Deafness

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02259192
Acronym
SSD
Enrollment
10
Registered
2014-10-08
Start date
2014-09-30
Completion date
2019-09-30
Last updated
2017-04-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Single-sided Deafness

Keywords

deaf adult, single-sided, cochlear implant

Brief summary

The purpose of this investigation is to determine the safety and preliminary efficacy of implanting a cochlear implant (CI) in the profoundly deaf ear of an adult with one normal hearing (NH) ear (termed single-sided deaf person, or SSD). The potential subjects will have been deafened post-lingually, thus, at one point the now deafened ear did conduct sound from the periphery. The MED-EL CI system will be implanted in ten (10) SSD patients.The long-term goal of this research program is to determine whether the CI, in combination with the NH ear, may provide improved localization ability and better speech understanding in noise, relative to performance before cochlear implantation (i.e., with the NH ear alone). A secondary long-term goal is to determine whether CI stimulation may reduce tinnitus severity, compared to tinnitus experienced prior to cochlear implantation or when the CI is turned off, after implantation.

Interventions

DEVICEMED-EL Maestro Cochlear Implant

cochlear implant

Sponsors

Med-El Corporation
CollaboratorINDUSTRY
House Clinic, Inc.
CollaboratorINDUSTRY
University of California, Los Angeles
CollaboratorOTHER
Robert Shannon
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Is an adult (18 years of age or older) * English as the primary language * Able to undergo general anesthesia, as determined by physical examination and written report from the physician * Receives pneumovax vaccine within 2 weeks of surgery and provides documentation to the principal investigator * Profoundly/severely deaf in one ear (implant ear), as defined by: * 3-frequency pure-tone average≥70 dB Hearing Loss * Bone conduction thresholds consistent with air conduction thresholds (i.e., no conductive component to the hearing loss) * HINT sentence recognition score ≤40% correct, 60 dBA presentation level * Post-lingual onset of hearing loss, i.e., after age 6 years of age * Hearing loss occurred \<10 years prior, as obtained by history * Normal hearing in one ear (non-implant ear), as defined by: * 3-frequency PTA ≤25 dB HL * No tested frequency air conduction threshold \>35 dB HL * Bone conduction thresholds consistent with air conduction thresholds * Word recognition score ≥80% correct, 60 dBA presentation level * HINT sentence recognition score ≥ 80%, 60 dBA presentation level * Provides informed consent * Willing and able to follow the study protocol

Exclusion criteria

* Retrocochlear pathology resulting from Neurofibromatosis 2, or other types of cranial nerve/brainstem tumors * Co-existing medical conditions that require radiotherapy of the brainstem and/or auditory cortex * Any medical contraindication precluding safe administration of general anesthesia, e.g., * Cardiopulmonary disease * Renal disease * Otologic conditions which contraindicate surgery * Active middle ear infection * Tympanic membrane perforation * Anatomic abnormalities detected on CT preventing appropriate placement of the stimulator housing in the bone of the skull or placement of the electrode array in the cochlea (e.g., ossification) * Psychological conditions contraindicating surgery * Skin or scalp conditions that may preclude attachment of the coil or that may interfere with the use of the coil * Chronic pain in or around the head * Current or previous use of an active hearing implant (e.g., bone-anchored hearing aids, cochlear implant, etc.) * Developmental delays or organic brain dysfunction

Design outcomes

Primary

MeasureTime frameDescription
Pure-tone threshold average (dB)6 months post-activationChange in 3-frequency pure-tone threshold average (dB) in the normal hearing ear.
Hearing in Noise Test (signal-to-noise ratio)6 months post-activationChange in Hearing in Noise Test signal-to-noise ratio in the normal hearing ear.

Secondary

MeasureTime frameDescription
Adverse Events1-month post-implantationNumber of unexpected serious adverse events across all 10 subjects.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 25, 2026