Laryngeal Mask Airway Supreme Versus Laryngeal Tube in Non-paralysed, Anesthetized Children. A Randomized, Crossover Study Assessing Oropharyngeal Leak Pressure and Fiberoptic Position Using the Size 2

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02252120
Enrollment
60
Registered
2014-09-29
Start date
2014-01-31
Completion date
2014-09-30
Last updated
2014-09-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Adverse Anesthesia Outcome

Brief summary

The investigators test the hypothesis that oropharyngeal leak pressure and fiberoptic position differ between the size 2 LMA SupremeTM and the Laryngeal Tube LTS IITM in non-paralyzed anaesthetized pediatric patients

Detailed description

The Laryngeal Tube LTS IITM (VBM-Medizintechnik GmbH, Sulz a.N, Germany) is a well established reusable latex free, extraglottic airway device. A proximal (pharyngeal) and a distal (esophageal) cuff are inflated with a single cuff pilot line. In between lies the ventilation orifice. The LMA SupremeTM (Teleflex San Diego, CA, USA) is a single use well studied laryngeal mask airway. Both devices have a drain tube to allow access to the gastrointestinal tract. Actually there are no studies comparing Laryngeal Tube LTS IITM and LMA SupremeTM use in small children. Therefore the aim of this study was to evaluate the clinical performance of the Laryngeal Tube LTS IITM compared to the LMA SupremeTM. The investigators hypothesized that design differences should lead to differences in efficacy of seal and anatomic position. In this randomized, crossover study, the investigators test the hypothesis that in non-paralyzed pediatric patients the oropharyngeal leak pressure and fiberoptic position differs between the size 2 Laryngeal Tube LTS IITM and the LMA SupremeTM.

Interventions

Sponsors

University of Salzburg
CollaboratorOTHER
Schulthess Klinik
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Months to 9 Years
Healthy volunteers
No

Inclusion criteria

* ASA I-II * age 1.5 - 9 years * minor surgery * extraglottic airway device

Exclusion criteria

* age (\<18 months, \>9 years) * weight (\<10 kg, \>25 kg) * a known difficult airway * risk of aspiration

Design outcomes

Primary

MeasureTime frameDescription
Oropharyngeal leak pressure5 MinOropharyngeal leak pressure was determined by closing the expiratory valve of the anaesthesia breathing system and a fixed gas flow of 3 l minute-1. The airway pressure at which an equilibrium was reached was noted (maximum allowed 40 cm H2O).

Secondary

MeasureTime frameDescription
Fiberoptic position5 MinThe airway tube view was scored using an established scoring system (4=only vocal cords visible; 3=vocal cords plus posterior epiglottis; 2=vocal cords plus anterior epiglottis; 1=vocal cords not seen)

Other

MeasureTime frameDescription
Ease of insertion1 MinWe allowed one attempt before considering a failure, defining failed insertion by any of the following criteria: 1\) failed passage into the pharynx; 2) malposition (air leaks); and 3) ineffective ventilation (maximum expired tidal volume \<4 ml kg-1 or end-tidal CO2 \> 50 mm Hg (if correctly positioned). ). Insertion time was defined as the interval between picking up the prepared device and successfully placement. After placement effective ventilation was tested by observation of chest wall movement and capnometric curve trace. If insertion failed the etiology was signed on the CRF. After a first insertion attempt one single attempt with the guiding technique was allowed.