Effect of Implant Position on Magnetic Resonance Image Distortion

The Effect of Changes in Head Position on Magnetic Resonance Image Distortion in Patients With Auditory Implants

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02246231
Enrollment
5
Registered
2014-09-22
Start date
2014-02-03
Completion date
2015-01-31
Last updated
2020-03-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Neurofibromatosis Type 2

Brief summary

Patients with Neurofibromatosis type 2 (NF2) almost always develop acoustic neuromas in both ears. As a result of the tumours themselves or the treatment of the tumours, many patients become profoundly deaf in both ears. It is possible to restore a degree of hearing by placing a hearing implant in the brainstem adjacent to the hearing pathways within the brain. This is termed an auditory brainstem implant (ABI). The aim of this study is to find the optimum head position in relation to the MRI magnet field, which would produce least area of image distortion in patients with ABIs. This will be of benefit in optimising the MR imaging in future patients with implants.

Detailed description

Auditory brainstem implants (ABI) are placed against the auditory centres in the brainstem if it is not possible to implant the cochlea or if the cochlear nerve, which conveys neural signals from the cochlea to the brainstem, is damaged or absent. The latter device is usually used in patients with Neurofibromatosis type 2 (NF2) who develop bilateral benign inner ear tumours called vestibular schwannomas as well as other neurological tumours1. These patients often become bilaterally profoundly deaf either as a result of the disease or because of surgery to remove the tumours and require an ABI. Patients with NF2 require monitoring of their tumours. In the absence of an auditory implant it is possible to use magnetic resonance imaging. This is the gold standard imaging technique as it gives excellent views of the soft tissues of head. However, there has been concern regarding the use of MRI in patients with auditory implants until recently because of potential problems such as demagnetisation of the magnet within the implant, implant magnet displacement and risk to the integrity of the implant electronics. In addition, the magnet field of the implant magnet results in imaging artefact (manifesting as a signal void) around the implant site that limits the information that can be obtained.

Interventions

DEVICEMR imaging

Sponsors

Manchester University NHS Foundation Trust
Lead SponsorOTHER_GOV

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

\- Any patient over the age of 18 with NF2 who has an auditory implant (cochlear or auditory brainstem implant) in situ and requires MRI scanning.

Exclusion criteria

Children under the age of 18 years Claustrophobia Bilateral implants Contraindications and relative contraindications for MRI (as per the Radiology Department MRI protocol) including: Pacemaker Certain metallic heart valves Ferromagnetic implanted materials and foreign bodies

Design outcomes

Primary

MeasureTime frame
To study the effect of magnet orientation in auditory brainstem implants/ cochlear implants in determining the size of signal void seen on MRI scanning.1 year

Secondary

MeasureTime frame
To identify if there is an angle at which the signal void is minimised1 year