Dynamic Quadriceps Muscle Stimulation for Treatment of Patellofemoral Pain

Dynamic Quadriceps Muscle Stimulation for Treatment of Patellofemoral Pain

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02243332
Enrollment
20
Registered
2014-09-17
Start date
2014-09-30
Completion date
2017-03-31
Last updated
2017-06-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anterior Knee Pain Syndrome, Patellofemoral Pain Syndrome

Keywords

Knee, Pain, Joint, Rehabilitation, Patellofemoral Pain Syndrome, Anterior Knee Pain Syndrome, Knee Pain, Quadriceps

Brief summary

The purpose of this small, pilot study is to evaluate a novel device that uses neuromuscular electrical stimulation to assist quadriceps muscles as a user walks. This study will involve use of this device on individuals with patellofemoral pain, a relatively common injury among active people, to see if quadriceps stimulation could mitigate disparities in quadriceps activation timing that may indirectly lead to knee pain.

Detailed description

The interventional device will be tested with 20 women aged 18-40 with evidence of patellofemoral pain syndrome (PFPS) and without any co-morbidities that would confound data or contraindications for NMES use. All participants will be enrolled at a single site (Developmental Motor Lab at the University of Texas), and all of a single participant's testing will be complete within a single day with no requirement for follow-up or long-term participation. Participants will have their gait and quadriceps muscle activation patterns evaluated through four six-minute walk tests (6MWT). The first 6MWT will be without a device, second with a device worn but not activated, third with a device activated and stimulating quadriceps musculature, and the fourth without a device. Primary Objective: The purpose of this study is to investigate whether electrical stimulation of the vastus medalis (VM) and/or vastus lateralis (VL) to establish coactivation of these muscles during terminal swing phase impacts severity of PFPS symptoms Secondary Objectives: Secondary purposes for this study include evaluating KneeStim and seeing if there is any evidence of proof of concept in two main areas: KneeStim as a therapeutic device that may assist individuals with joint rehabilitation KneeStim's on-board operating system and motion tracking system as an effective way to monitor joint kinematics. This pilot study has a prospective, controlled, single-center design. Participants and investigators will not be blinded to the treatment. Individuals who evaluate the motion-tracking data between VICON and KneeStim will not be informed which data set aligns with which treatment.

Interventions

DEVICEKneeStim mobile rehabilitation assistance device

KneeStim is a neuromuscular electrical stimulation (NMES) device that integrates motion-tracking hardware like three-axis accelerometers and a real-time operating system to enable quadriceps muscle stimulation in time with user gait. It is a completely non-invasive device that looks like a light brace and fastens to the user's quadriceps and gastrocnemius muscles. The end goal of this device is to assist with muscle re-strengthening and re-education during a user's everyday activities.

Sponsors

University of Texas at Austin
CollaboratorOTHER
Articulate Labs
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 40 Years
Healthy volunteers
No

Inclusion criteria

* Aged 18-40 years * Symptomatic PFPS on Patella Glide Test, Patella Tilt Test, and Patellar Apprehension Test.

Exclusion criteria

* Rheumatoid arthritis or inflammatory arthritis as assessed by licensed physician * Use of walking aids other than a cane more than 50% of the time in ambulation * Diagnosed knee disorder other than patellofemoral syndrome * Pacemaker use, unstable angina, or decompensated heart failure * Knee replaced in preceding 12 months or replacement planned within 6 months * Moderate to severe dementia * Pregnancy (self report) * Altered sensation at the knee such that the patient is unable to perceive the presence of pinprick. * Use of intra-articular viscosupplementation or steroid injection within preceding 2 months. * Use of chronic anticoagulation medication. * Movement-limiting pain in the back, hip, ankle, or foot of either lower limb.

Design outcomes

Primary

MeasureTime frameDescription
Measured Quadriceps Musculature Co-Contraction20, 40, 60, 80 minutes from start of single-day testingElectromyographic (EMG) readings of vastus lateralis and vastus medialis contraction patterns will be taken after four six-minute walk tests (6MWTs) to evaluate any short-term changes in co-contraction. 6MWT #1: Without interventional device being worn; 6MWT #2: With interventional device being worn, but unpowered; 6MWT #3: With interventional device being worn and operational; 6MWT #4: Without interventional device being worn The time period in which a partipant will be involved is not expected to exceed 90 minutes.

Secondary

MeasureTime frameDescription
Anterior Knee Pain20, 40, 60, 80 minutes from start of single-day testingMeasured with Anterior Knee Pain Scale (AKPS) after each Six Minute Walk Test.
Device Joint Model Accuracy20, 40, 60, 80 minutes from start of single-day testingThe interventional device uses an on-board operating system that determines stimulation timing and location based on modeled joint kinematics. Movement data will be taken from the device and evaluated against movement data measured by a VICON motion-tracking system during each six-minute walk test to evaluate the accuracy of the device's modeled joint kinematics.

Countries

United States

Outcome results

None listed