CT for Pulmonary Thromboembolic Disease

Individually Optimized Uniform Contrast Enhancement in CT Angiography for the Diagnosis of Pulmonary Thromboembolic Disease

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02241525
Acronym
CT for PE
Enrollment
2
Registered
2014-09-16
Start date
2016-02-29
Completion date
2016-05-31
Last updated
2020-03-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pulmonary Embolism

Keywords

Pulmonary, Thromboembolic, Lung

Brief summary

Examine the feasibility and efficacy of individually optimized uniform contrast enhancement in CT pulmonary angiography (CTPA) for the diagnosis of pulmonary thromboembolic disease.

Detailed description

Patient characteristics, qualitative image quality scores, and quantitative contrast enhancement and CNR will be described using mean values and standard deviations for continuous variables, and frequencies and percent for categorical variables. Difference between the two patient groups will be compared using Wilcoxon signed rank tests and chi-square statistics for continuous and categorical variables, respectively. All statistical tests will be performed at a significance level of 0.05.

Interventions

None listed

Sponsors

University of Maryland, Baltimore
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients 18 years old or older * Patients who have been recommended for CTPA scan for the diagnosis of pulmonary; thromboembolic disease (PE) in the Department of Diagnostic Radiology and Nuclear Medicine at the University of Maryland-Patients whose body mass index (BMI) is greater than 30 kg/m2. * Patients whose body mass index (BMI) is greater than 30 kg/m2 * Patients who signed the University of Maryland Medical Center Consent for Intravenous Contrast Administration

Exclusion criteria

* Pregnant or breast-feeding women; Female participants of childbearing age (10 - 60 years) will be screened for their pregnancy status prior to study registration, by following the Department of Diagnostic Radiology and Nuclear Medicine CLINICAL STANDARD Procedure DI-AOP-003 Pregnancy Screening Documentation; - Patients with decreased renal function34-36. This is evaluated by blood work checked within 30 days prior to the CTPA scan with contrast. Patients cannot receive contrast if their BUN index is not within \[7-20\] or creatinine is not within \[0.5 - 1.4\] mg/dL * Patients with decreased renal function34-36. This is evaluated by blood work checked within current admission for inpatients or within 30 days for outpatients prior to the CTPA scan with contrast. Patients cannot receive contrast if their serum creatinine level exceeds 2.0 mg/dL * Patients with known moderate or severe allergic reactions to contrast, including but not limited to: shortness of breath, a change in baseline vital signs, such as a change in blood pressure, tachycardia, increased respirations that can progress to major respiratory distress, laryngeal edema, bronchospasm, arrhythmias, convulsions, and cardiopulmonary arrest.

Design outcomes

Primary

MeasureTime frameDescription
Feasibility of patients with individually optimized bi-phasic contrast injection for CTPA scan1 yearThe primary endpoint is to study the feasibility( bi-phasic vs. singular pahse contrast injection (by comparison analysis)) of individually optimized bi-phasic contrast injection for CTPA scan.
Efficacy of PE diagnosis with CTPA imaging1 yearTo quantify the efficacy (by comparison analysis) of PE diagnosis of this new contrast injection protocol in terms of reduced frequency of non-diagnostic CTPA image vs. standard of care procedures.

Secondary

MeasureTime frameDescription
# of patients who receive contrast enhancement and CNR of CTPA scans1 yearA secondary endpoint is to quantitatively evaluate (by comparison analysis) the contrast enhancement and CNR of CTPA scans. Twenty patients (20) will be enrolled and scanned with the RESEARCH procedures. Another twenty retrospective patients (20) with matching age and BMI will be selected from existing patients with a CLINICAL STANDARD of Care CTPA scan and enrolled on retrospective protocol: HP-00056512 Individually optimized uniform contrast enhancement in CT angiography for the diagnosis of pulmonarythromboembolic disease - A simulation study.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026