Skip to content

Performance Evaluation of the Depth of Anesthesia Monitors in Pediatric Surgery

Performance Evaluation of the Depth of Anesthesia Monitors in Pediatric Surgery. Bispectral VISTA and ENTROPY Monitor for Pediatric Anesthesia.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02240368
Enrollment
50
Registered
2014-09-15
Start date
2014-09-30
Completion date
2014-12-31
Last updated
2018-08-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anesthesia, Child

Keywords

Depth anesthesia monitors, Children anesthesia, Bispectral monitor, Entropy monitor

Brief summary

The purpose of this study is to determine how Bispectral index (BIS) and Entropy EEG monitors agree between themselves and with end-tidal concentration of sevoflurane (ETsevo) in relationship with the age in the pediatric surgery setting. Bispectral index (BIS) and Entropy EEG monitors performance and utility is well established in adult general anesthesia. Their utility is yet undefined in the pediatric population as age seems to affect their ability to track the cerebral hypnotic state in children.

Detailed description

All patients monitored applying standard device for blood pressure, electrocardiogram and pulse oximeter for routine monitor of anesthesia in pediatric surgery. Bispectral VISTA monitor and Entropy monitor applied for monitoring the depth of anesthesia. The investigators will not assign any specific interventions to the subjects of the study.

Interventions

None listed

Sponsors

University College, London
CollaboratorOTHER
University of Foggia
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Months to 12 Years
Healthy volunteers
No

Inclusion criteria

* physical status classification (ASA) I - II * general balanced anesthesia * mechanically ventilated with laryngeal mask

Exclusion criteria

* severe developmental delay * neurological disorders or receiving treatment with antiepileptic or stimulant * patients with preexisting lung or cardiac disease * airway abnormalities * marked skin sensitivity and conditions where the placement of the BIS and Entropy sensor or process of assessment would interfere with the surgery procedure. * patients receiving local anaesthesia, regional block combined with general anaesthesia * sedation administered by non anesthesiologists for invasive and noninvasive diagnostic or therapeutic procedures

Design outcomes

Primary

MeasureTime frameDescription
BISPECTRAL IndexBISPECTRAL index values from the induction moment to the awakening moment, 1/5 sec sampling rate, an average of 1 hoursThe collected values of bispectral index and end tidal sevofluorane will generate a single prediction probability (PK) of agreement between bispectral index vs end-tidal sevofluorane along the whole period of anesthesia for each arm/group. Prediction probability (PK) is a statistical measure that is particularly suited to assess the performance of anesthetic depth indicators. It quantifies the correlation between observed anesthetic depth and indicator values. PK allows a simple interpretation and, as a non parametric measure, it is independent from scale units and assumptions on underlying distributions.
EntropyEntropy values from the induction moment to the awakening moment, 1/5 sec sampling rate, an average of 1 hoursThe collected values of Entropy will generate a single prediction probability (PK) of agreement between Entropy vs end-tidal sevofluorane along the whole period of anesthesia for each arm/group. Prediction probability (PK) is a statistical measure that is particularly suited to assess the performance of anesthetic depth indicators. It quantifies the correlation between observed anesthetic depth and indicator values. PK allows a simple interpretation and, as a non parametric measure, it is independent from scale units and assumptions on underlying distributions.

Secondary

MeasureTime frameDescription
BISPECTRAL Index Awakingreported moment of awakening from anesthesia, an average of 1 hours after administration of AnesthesiaIn each patient the Bispectral index values at the moment of first signs of awakening.The Bispectral index monitor provides a single dimensionless number, which ranges from 0 (equivalent to EEG silence) to 100 (deepest/highest level of anesthesia). A BIS value between 40 and 60 indicates an appropriate level for general anesthesia, as recommended by the manufacturer
Entropy Awakingreported moment of awakening from anesthesia, an average of 1 hours after administration of AnesthesiaIn each patient the Entropy values at the moment of first signs of awakening. The Entropy monitor provides a single dimensionless number, which ranges from 0 (equivalent to EEG silence) to 100 (deepest/highest level of anesthesia). A Entropy value between 40 and 60 indicates an appropriate level for general anesthesia, as recommended by the manufacturer

Countries

Italy

Participant flow

Participants by arm

ArmCount
Group 1
Children age between 1 month to 12 months
8
Group 2
Children age between 13 months and 36 months
22
Group 3
Children age between 37 months to 144 months
18
Total48

Withdrawals & dropouts

PeriodReasonFG000FG001FG002
Overall StudyEntropy failed to detect more than 50%001
Overall StudySurgery lasted less then 20 minutes100

Baseline characteristics

CharacteristicGroup 2Group 3Group 1Total
Age, Categorical
<=18 years
22 Participants18 Participants8 Participants48 Participants
Age, Categorical
>=65 years
0 Participants0 Participants0 Participants0 Participants
Age, Categorical
Between 18 and 65 years
0 Participants0 Participants0 Participants0 Participants
Age, Continuous24.95 months
STANDARD_DEVIATION 8
82.22 months
STANDARD_DEVIATION 33.8
6.63 months
STANDARD_DEVIATION 3.7
43.38 months
STANDARD_DEVIATION 37.56
Region of Enrollment
Italy
22 participants18 participants8 participants48 participants
Sex: Female, Male
Female
8 Participants9 Participants4 Participants21 Participants
Sex: Female, Male
Male
14 Participants9 Participants4 Participants27 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
EG002
affected / at risk
deaths
Total, all-cause mortality
— / —— / —— / —
other
Total, other adverse events
0 / 80 / 220 / 18
serious
Total, serious adverse events
0 / 80 / 220 / 18

Outcome results

Primary

BISPECTRAL Index

The collected values of bispectral index and end tidal sevofluorane will generate a single prediction probability (PK) of agreement between bispectral index vs end-tidal sevofluorane along the whole period of anesthesia for each arm/group. Prediction probability (PK) is a statistical measure that is particularly suited to assess the performance of anesthetic depth indicators. It quantifies the correlation between observed anesthetic depth and indicator values. PK allows a simple interpretation and, as a non parametric measure, it is independent from scale units and assumptions on underlying distributions.

Time frame: BISPECTRAL index values from the induction moment to the awakening moment, 1/5 sec sampling rate, an average of 1 hours

ArmMeasureValue (NUMBER)
Group 1BISPECTRAL Index0.6 units on a scale
Group 2BISPECTRAL Index0.66 units on a scale
Group 3BISPECTRAL Index0.73 units on a scale
p-value: <0.01bootstrap
Primary

Entropy

The collected values of Entropy will generate a single prediction probability (PK) of agreement between Entropy vs end-tidal sevofluorane along the whole period of anesthesia for each arm/group. Prediction probability (PK) is a statistical measure that is particularly suited to assess the performance of anesthetic depth indicators. It quantifies the correlation between observed anesthetic depth and indicator values. PK allows a simple interpretation and, as a non parametric measure, it is independent from scale units and assumptions on underlying distributions.

Time frame: Entropy values from the induction moment to the awakening moment, 1/5 sec sampling rate, an average of 1 hours

ArmMeasureValue (NUMBER)
Group 1Entropy0.64 units on a scale
Group 2Entropy0.66 units on a scale
Group 3Entropy0.72 units on a scale
p-value: <0.01bootstrap
Secondary

BISPECTRAL Index Awaking

In each patient the Bispectral index values at the moment of first signs of awakening.The Bispectral index monitor provides a single dimensionless number, which ranges from 0 (equivalent to EEG silence) to 100 (deepest/highest level of anesthesia). A BIS value between 40 and 60 indicates an appropriate level for general anesthesia, as recommended by the manufacturer

Time frame: reported moment of awakening from anesthesia, an average of 1 hours after administration of Anesthesia

ArmMeasureValue (MEDIAN)
Group 1BISPECTRAL Index Awaking75 units on a scale
Group 2BISPECTRAL Index Awaking86 units on a scale
Group 3BISPECTRAL Index Awaking81 units on a scale
p-value: 0.01Wilcoxon (Mann-Whitney)
Secondary

Entropy Awaking

In each patient the Entropy values at the moment of first signs of awakening. The Entropy monitor provides a single dimensionless number, which ranges from 0 (equivalent to EEG silence) to 100 (deepest/highest level of anesthesia). A Entropy value between 40 and 60 indicates an appropriate level for general anesthesia, as recommended by the manufacturer

Time frame: reported moment of awakening from anesthesia, an average of 1 hours after administration of Anesthesia

ArmMeasureValue (MEDIAN)
Group 1Entropy Awaking63 units on a scale
Group 2Entropy Awaking96 units on a scale
Group 3Entropy Awaking86 units on a scale
p-value: <0.01Wilcoxon (Mann-Whitney)

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026