Investigating Proximal Migration in Trabecular Metal Cups Used In Acetabular Revision Surgery

Is the Trabecular Metal Cup Associated With Lower Risk of Aseptic Loosening in Acetabular Revision Surgery?

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02237482
Enrollment
100
Registered
2014-09-11
Start date
2006-07-31
Completion date
2011-12-31
Last updated
2014-09-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Prosthesis Loosening

Brief summary

This study is intended to compare the proximal migration of the tantalum design (TM) with a cemented cup used in conjunction with bone allografting in cases with major bone loss. A group of patients with good periacetabular bone stock are included to analyse the differences between the tantalum and titanium design regarding risk of loosening and differences in clinical outcome measures. Radiostereometry (RSA) is used to accurately measure migration and rotation of the revision cups.

Detailed description

Acetabular component loosening is often associated with periacetabular bone loss. Different approaches are described to address the bone defects in acetabular revision surgery. Several authors have reported inferior results when uncemented Titanium alloys and older porous coated designs are used in acetabular revisions with significant bone loss. Cemented fixation of the revision cup with impaction bone grafting (BIG), introduced more than three decades ago has today a thorough documentation. The Tantalum designs, with inherent properties such as high volumetric porosity, low modulus of elasticity and high friction against the bone, have been suggested to improve the fixation of the acetabular component. Several authors have been reporting promising short- and medium-term results using the TM designs in acetabular revisions with large periacetabular bone defects. Proximal migration measured with radiostereometry (RSA) has been suggested to predict risk for late aseptic loosening in hip prosthesis surgery. This study was primarily to compare the proximal migration of the tantalum design with a cemented cup used in conjunction with bone allografting in cases with major bone loss. A group of patients with good periacetabular bone stock are included to analyse the differences between the tantalum and titanium design. RSA is used to accurately measure migration and rotation of the revision cups.

Interventions

DEVICETrilogy cup
DEVICETrabecular metal cup (TM)
DEVICEZCA cup

Sponsors

Sahlgrenska University Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
No minimum to 85 Years
Healthy volunteers
No

Inclusion criteria

All patients with a loose acetabular component, undergoing revision

Exclusion criteria

Patient not able to understand the intention of the study

Design outcomes

Primary

MeasureTime frameDescription
Proximal migration measured with RSA24 month postoperatively.All patients have been recruited (operated on) by end of December 2011. Our primary intention is to follow all patients a minimum of two years with RSA.

Secondary

MeasureTime frameDescription
Patient reported outcome measuresfirst two years postoperativelyHarris Hip Score

Other

MeasureTime frame
Re-revision due to aseptic loosening or radiographical looseningminimum13 years postoperative
EuroQol 5Dfirst two years postoperatively.