Understanding Angioplasty by the Chocolate PTA Balloon Catheter Compared to Conventional PTA Balloons Via OCT Imaging

Understanding the Mechanism of Peripheral Arterial Balloon Angioplasty by the Chocolate PTA Balloon Catheter Compared to Conventional PTA Balloons Via OCT Imaging

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02237066
Enrollment
0
Registered
2014-09-11
Start date
2014-09-30
Completion date
2015-03-31
Last updated
2015-03-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Infrainguinal Peripheral Arterial Disease

Keywords

OCT, PTA, Balloon

Brief summary

The purpose of this study is to compare the Chocolate PTA Balloon to standard Percutaneous Transluminal Angioplasty (PTA) catheters. The investigators will use Optical Coherence Tomography (OCT) and Quantitative Vascular Angiography to evaluate the acute vascular response of vessels treated with the Chocolate Balloon to a standard balloon catheter, with the primary endpoint being luminal gain assessed by OCT lumen volume measurements.

Detailed description

Subjects will be randomized to treatment with either the Chocolate Balloon catheter or a standard balloon angioplasty catheter. All angioplasty procedures will be conducted with treatment balloon at the full discretion of the physician and according to the standard practice at the hospital and the device Instructions for Use. All patients will undergo baseline OCT imaging in addition to standard angiography. Post-PTA, all patients will then undergo repeat OCT imaging immediately post-procedure and then again at 10-minutes post-procedure to assess for vascular recoil.

Interventions

DEVICEChocolate PTA Balloon Angioplasty

OCT imaging of diseased vessel is treated with an Angioplasty Procedure using the Chocolate PTA Balloon Catheter followed by OCT imaging of the treated area immediately after balloon use and 10 minutes later

DEVICEStandard PTA Balloon Angioplasty

OCT imaging of diseased vessel is treated with an Angioplasty Procedure using a standard PTA Balloon Catheter followed by OCT imaging of the treated area immediately after balloon use and 10 minutes later

Sponsors

University Hospitals Cleveland Medical Center
CollaboratorOTHER
TriReme Medical, LLC
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Reference Vessel Diameter (RVD) between 2.5 and 6.0mm and within treatment range of available balloon at Target Lesion * Intermittent claudication or critical limb ischemia (Rutherford 3-5) * De novo stenosis (≥70%) or occlusion in the infrainguinal arteries, including superficial femoral artery (SFA), popliteal, and infrapopliteal arteries. * Lesion successfully crossed with a guide-wire * Patient has given informed consent to participate in this study

Exclusion criteria

* Lesion requiring ablative procedures (i.e. atherectomy or laser) as part of treatment * Lesion length \>75mm * Previous bypass or stent at target vessel or proximal to target vessel * Significant in-flow disease at target lesion * Known inadequate distal outflow disease or planned treatment of vessel distal to target lesion * Acute limb ischemia or need for thrombolytic therapy * Known intolerance to required study medications, contrast media, or nitinol * Known impaired Renal Function with Glomerular Filtration Rate (GFR) \<45 ml/min per 1.73m2 * Known bleeding disorder or uncontrolled hypercoagulable disorder.

Design outcomes

Primary

MeasureTime frameDescription
Luminal GainAverage of 90 minutesLuminal Gain as defined by OCT lumen volume measurements. Luminal gain is assessed as the percentage change comparing pre-treatment and post-treatment volume measurements in cubic centimeters (CC) or millimeters (m3).

Secondary

MeasureTime frameDescription
DissectionAverage of 90 minutesDissection severity (extension) as defined by both angiographic and OCT metrics. Dissections occur when the blood goes into the vessel wall instead of staying in the vessel lumen. Dissection severity is determined by a visual review of the angiogram and OCT images by an independent core lab. Dissections are classified as flow-limiting (more severe) vs. non-flow limiting (less severe) based upon the amount of the blood that is flowing into the vessel wall.
HematomaAverage of 90 minutesPresence of intramural hematoma on OCT. A hematoma can be visually observed on a angiogram and an OCT image. The images will be independently reviewed by a core lab expert who will document if a hematoma is present or not.
Optimal PTAAverage of 90 minutesAchievement of Optimal PTA (\<30% Diameter stenosis without flow limiting dissection) \<30% Diameter stenosis and flow limiting dissections are visual assessments that will be conducted by an independent core lab review. The % diameter stenosis measures the amount of plaque that is in the vessel and a flow-limiting dissection is observed as either present or not present.