Visual Quality Change of Eyes Implanted With Diffractive Multifocal Intraocular Lens After Cataract Surgery

Phase 1 Evaluate the Visual Quality Change of Eyes Implanted With Multifocal Intraocular Lens and Monofocal Lenses; Phase 2 Evaluate the Tear Film Quality Dynamics of Eyes Implanted With Multifocal Intraocular Lens and Monofocal Lenses.

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02234635
Enrollment
50
Registered
2014-09-09
Start date
2012-08-31
Completion date
2015-02-28
Last updated
2014-09-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dry Eye, Quality of Life, Vision Disorders

Keywords

visual acuity, objective visual quality, multifocal intraocular lens, tear-film quality dynamics

Brief summary

In this study, the investigators examined the subjective visual quality including LogMAR uncorrected distance visual acuity (UCDVA), best corrected distance visual acuity (BCDVA),uncorrected intermediate visual acuity (UCIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UCNVA) ,distance corrected near visual acuity (DCNVA),using logMAR visual acuity chart,and the objective visual quality including Modulation Transfer Function (MTF), Strehl ratio(SR), objective scatter index (OSI), OQAS value (OV),and the tear-film quality dynamics including the tear break-up time and the tear-film OSI between the eyes with multifocal lens and monofocal lenses by optical quality analysis system (OQAS).

Detailed description

50 eyes of 50 cataract patients scheduled for phacoemulsification surgery were recruited, the multifocal group (25 eyes) ,were implantation with Tecnis® ZMB00;and the monofocal group (25 eyes) were implantation with Tecnis® ZCB00. Methods: All eyes were examined by logMAR visual acuity chart and Optical quality analysis system (OQAS) at 1 week, 1 month, 3 month, 6 month,12 month after surgery for the subjective and objective visual quality Change during the first year. Measures:Subjective and objective visual quality were evaluated.Tear-film quality dynamicswere evaluated.

Interventions

OTHERDiffractive multifocal IOLs group

Diffractive IOLs are a type of multifocal (bifocal) IOL that are based on the Huygens-Fresnel principle. Specifically, a diffractive IOL has concentric rings in its posterior surface that form 2 primary focal points independent of pupil size. This optical behavior of the IOL can effectively restore far and near vision. However, it can also cause side effects, such as halos and glare and loss of contrast sensitivity.

Sponsors

Wenzhou Medical University
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
50 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Eyes with an axial length of 22.00 to 25.00 mm with age-related cataract.

Exclusion criteria

* Preoperative

Design outcomes

Primary

MeasureTime frameDescription
To evaluate the Visual Quality Change of Eyes Implanted With Diffractive Multifocal Intraocular Lens1week, 1month, 3month,6month,12monthVisual quality change during the first year after cataract surgery. The visual quality including the subjective and objective visual quality. The subjective visual quality including LogMAR uncorrected distance visual acuity (UCDVA), best corrected distance visual acuity (BCDVA),uncorrected intermediate visual acuity (UCIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UCNVA) and distance corrected near visual acuity (DCNVA). The objective visual quality including Modulation Transfer Function (MTF), Strehl ratio(SR), objective scatter index (OSI) and OQAS value (OV).

Secondary

MeasureTime frameDescription
To evaluate the Tear-film Quality Dynamics of Eyes Implanted With Diffractive Multifocal Intraocular Lens1week, 1month, 3month,6month,12monthThe tear-film quality dynamics including the tear break-up time and the tear-film OSI were examined by optical quality analysis system (OQAS)

Countries

China

Contacts

Primary ContactFang Yu
357574103@qq.com13758452287

Outcome results

None listed