Ambu Aura-i Laryngeal Mask Versus Air-Q Intubating Laryngeal Airway for Tracheal Intubation in Adults

Ambu® Aura-iTM Laryngeal Mask Versus Air-QTM Intubating Laryngeal Airway as Conduits for Tracheal Intubation in Adults. A Randomized Comparative Clinical Trial

Status
UNKNOWN
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02226211
Enrollment
50
Registered
2014-08-27
Start date
2014-06-30
Completion date
Unknown
Last updated
2014-08-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Failed or Difficult Intubation (Anaesthesia Complications)

Brief summary

Supraglottic airway devices (SGA) become a routine part of the daily anesthesia practice. they can be used as primary airway devices or as conduits for endoracheal intubation and they become an integral part in the recent guidelines for managing difficult airway. Air-Q ILA has been used successfully as 1ry airway and also as a conduits for endotracheal intubation. The Ambu® Aura-i TM laryngeal mask is a new disposable SGA claimed to have special advantage over the competitors but not will studied as a conduit for endoracheal intubation. This study is designed to compare the performance of Ambu®Aura-i™ laryngeal mask with the air-Q ILA as conduits for fiberoptic-guided tracheal intubation in adult population.

Interventions

DEVICEAir-Q intubation laryngeal airway

The size selection of the air-Q ILA will follow the manufacture guideline to be size 3.5 for females and size 4.5 for males After induction of general anesthesia, the devices will be inserted by using midline insertion technique, then cuff will be inflated according to manufacture recommendations. After successful insertion of the air-Q, the appropriate endoracheal tube (ETT) will be loaded over the fiberoptic bronchoscopy, and the connector will be removed too. The bronchoscope will be introduced and advanced throughout the airway tube to just proximal to ventilating orifice, a video image of the fiberoptic view will be recorded and saved on CD to be graded later by an independent observe. The fiberoptic then will be advanced and once the carina is seen, the ETT is will be slided into the trachea. After successful intubation, the device will be removed according to the manufactures guides using removal stylet .

DEVICEAmbu-Aura i laryngeal mask

The size selection of the device will follow the manufacture guideline according to the patient weight, size 4 for (50-70kg), size 5 (70-100) and size 6 (\> 100kg). After induction of general anesthesia, the devices will be inserted by using midline insertion technique, then cuff will be inflated according to manufacture recommendations. After successful insertion of the aura-i, the appropriate endoracheal tube (ETT) will be loaded over the fiberoptic bronchoscopy, and the connector will be removed too. The bronchoscope will be introduced and advanced throughout the airway tube to just proximal to ventilating orifice, a video image of the fiberoptic view will be recorded and saved on CD to be graded later by an independent observe. The fiberoptic then will be advanced and once the carina is seen, the ETT is will be slided into the trachea. After successful intubation, the device will be removed according to the manufactures guides using another ETT.

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

* patients aged from 18-60 years old, ASA I and II and scheduled for elective surgery under general anesthesia

Exclusion criteria

* history of cardiopulmonary disease, gastro-esophageal reflux disease, abnormal airway anatomy, body mass index \> 30 kg.m-2, surgical procedures including head and neck or performed in position other than supine or lithotomy

Design outcomes

Primary

MeasureTime frame
duration of fiberoptic guided insertion of the ETT through the deviceduration of induction of general anesthesia, an expected average of 20 minutes. and it is the time span between disconnection of the breathing circuit from the device till reconnection to the ETT and appearance of 1st capnogram wave.

Secondary

MeasureTime frame
duration of device insertionduration of induction of general anesthesia, an expected average of 20 minutes and it is the time span between removal of the face mask till device insertion and the chest rise seen after two consecutive positive pressure manual breaths.
Time of device removalduration of induction of general anesthesia, an expected average of 20 minutes, and it is the time span between disconnection of the breathing circuit from ETT and reconnection to ETT after device removal with appearance of the 1st capnogram wave.
number of insertion attemptsduration of induction of general anesthesia, an expected average of 20 minutes and it is the time span from removal of face mask till complete insertion or failed third insertion trial of the device
complication during the procedureaverage of 20 minutes after induction of general anesthesia, it is the time from removal of face mask, till removal of the device and appearance of the first wave on the capnogram