Skip to content

Safety of Spine Radiofrequency Procedures

Safety of Lumbar Spine Radiofrequency Procedures in the Presence of Posterior Pedicle Screws: A Prospective Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02210052
Enrollment
6
Registered
2014-08-06
Start date
2014-09-30
Completion date
2015-12-31
Last updated
2017-07-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Radiofrequency Ablation in Patients With Spinal Hardware

Keywords

radiofrequency ablation

Brief summary

The goal of the study was to determine if patients undergoing radiofrequency neurotomy (RFN) of lumbar facet joints that are adjacent to previously placed pedicle screws from a fusion, would lead to an increase in the temperature of the pedicle screws.

Detailed description

This study was a prospective clinical trial, examining outcomes related to temperature increases in pedicle screws. It was not possible to blind the investigators or the patient. Outcomes related temperature differences were collected at each pedicle screw adjacent to a zygapophyseal joint being treated. A conventional 18-gauge, 1-cm curved active tip radiofrequency cannula was placed under fluoroscopic guidance to the area to be treated (the junction of the transverse process and the superior articulating process of the facet joint). This position placed the tip of the radiofrequency cannula immediately adjacent to, but not in direct contact with, the pedicle screws. The radiofrequency cannula was connected to a radiofrequency generator, and the conventional settings for clinical medial branch neurotomy was used, heating the tissue to 80°C for 90 seconds. The procedure described up to this point is the normal procedure and protocol for RFN performed at the Mayo Clinic. The experimental portion of the procedure is as follows: A separate 22 gauge radiofrequency cannula was intentionally placed in direct contact with the dorsal surface of the pedicle screws and was connected to a radiofrequency generator solely for the purpose of measuring temperature, as the RF cannula are dual purpose probes capable of both conducting energy for the radiofrequency lesion and monitoring tissue temperature. In other words, this small gauge needle was placed for the sole purpose of acting as a thermistor probe/temperature monitor. This process was repeated for each level necessary for treatment.

Interventions

DEVICERadiofrequency cannula

Subjects with spinal hardware that are undergoing radiofrequency ablation procedures will have an additional radiofrequency cannula placed at the site of adjacent pedicle screws for temperature measurement only.

Sponsors

Mayo Clinic
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

\- Scheduled for Radiofrequency procedure AND has spinal hardware placed from a previous spinal surgery

Exclusion criteria

* Active infection over skin where needle will be placed * Coagulopathy * Pregnancy

Design outcomes

Primary

MeasureTime frameDescription
Number of Procedures in Which Temperature of Screws Increased2 hoursThe study will measure for increased temperature in pedicle screws adjacent to lumbar facet joints during radiofrequency neurotomy (RFN). Temperatures will be recorded by placing a thermistor probe on the surface of the adjacent hardware.

Countries

United States

Participant flow

Participants by arm

ArmCount
Radiofrequency Neurotomy Subjects
Subjects with spinal hardware that are undergoing radiofrequency ablation procedures will have an additional radiofrequency cannula placed at the site of adjacent pedicle screws for temperature measurement only.
6
Total6

Baseline characteristics

CharacteristicRadiofrequency Neurotomy Subjects
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
1 Participants
Age, Categorical
Between 18 and 65 years
5 Participants
Age, Continuous47.8 years
Region of Enrollment
United States
6 participants
Sex: Female, Male
Female
1 Participants
Sex: Female, Male
Male
5 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 6
other
Total, other adverse events
0 / 6
serious
Total, serious adverse events
0 / 6

Outcome results

Primary

Number of Procedures in Which Temperature of Screws Increased

The study will measure for increased temperature in pedicle screws adjacent to lumbar facet joints during radiofrequency neurotomy (RFN). Temperatures will be recorded by placing a thermistor probe on the surface of the adjacent hardware.

Time frame: 2 hours

Population: There were 6 participants, but some participants had more than 1 procedure. There were a total of 10 procedures analyzed.

ArmMeasureGroupValue (NUMBER)
Radiofrequency Neurotomy SubjectsNumber of Procedures in Which Temperature of Screws IncreasedNon-significant increase4 procedures
Radiofrequency Neurotomy SubjectsNumber of Procedures in Which Temperature of Screws IncreasedSignificant increase; procedure stopped2 procedures

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026