Skip to content

Clinical Performance of Reveal G4 Rapid HIV-1 Antibody Test

Clinical Performance of Reveal G4 Rapid HIV-1 Antibody Test for the Detection of HIV-1 Antibodies in Fingerstick and Venous Whole Blood Samples

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02190578
Enrollment
1649
Registered
2014-07-15
Start date
2014-07-31
Completion date
2015-03-31
Last updated
2015-04-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

HIV Infections

Brief summary

To determine the efficacy of an improved rapid diagnostic test using venous whole blood and fingerstick whole blood. The clinical performance of Reveal G4 Rapid HIV-1 Antibody Test will be determined by comparing the results with patient infected status for HIV-1 (human immunodeficiency virus type 1). The study will consist of a single one-hour visit, at which time blood samples will be collected and tested with the investigational device (Reveal G4) and FDA approved comparator assays for detection of HIV-1 antibodies.

Detailed description

This clinical trial is a multi-center study to assess the performance characteristics of a rapid in vitro diagnostic assay, the Reveal G4 Rapid HIV-1 Antibody Test (Reveal G4). Specifically, the objective of this study is to determine the sensitivity and specificity of Reveal G4 in finger stick and venous whole blood, relative to FDA approved reference assays for the detection of HIV-1 antibodies. Approximately 1500-2000 subjects in total will be enrolled in the study across all sites, into three different study populations. Population 1 will be comprised of at least 500 subjects from a population at risk of infection with HIV. Population 2 will be comprised of at least 500 subjects that are known HIV positive individuals. Population 3 will be comprised of at least 500 subjects from a population at low risk of HIV infection. Reveal G4 will be used to test fingerstick whole blood and venous whole blood samples from all study subjects. For enrolled subjects in Populations 1 and 3, who are of unknown HIV antibody status, a plasma sample prepared from the venous whole blood sample will also be tested with an algorithm of FDA-approved assays for the detection of HIV-1 antibodies. For Population 2 subjects who are known HIV-positive individuals, results of previous HIV tests will be obtained from the subjects' medical records. The sensitivity and specificity of Reveal G4 will be determined in fingerstick and venous whole blood relative to HIV-1 antibody status as determined by an algorithm of FDA-approved assays. The primary analysis will involve comparison of Reveal G4 results for anti-HIV-1 in each sample matrix (fingerstick whole blood and venous whole blood) with the subject's HIV-1 antibody status as determined by FDA-approved assays. Based on the above, the sensitivity and specificity of Reveal G4 will be determined with corresponding two-sided 95% confidence intervals for both fingerstick and venous whole blood.

Interventions

DEVICEReveal G4

All subjects tested with the investigational device, Reveal G4, plus with an algorithm of approved assays for HIV.

Sponsors

MedMira Laboratories Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
13 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* All subjects must be at least 18 years of age, able to sign consent form, complete the risk assessment questionnaire, and provide the required blood samples: fingerstick sample (1 drop), venous whole blood sample (1 K2 EDTA tube). * Population 1 - Individuals at risk of HIV infection (n ≥ 500) Subjects must meet have at least one risk factor for infection with HIV * Population 2 - Known HIV-1 positive individuals (n ≥ 500) Subjects must be a known HIV-positive individual (previous positive HIV test result) * Population 3 - Individuals at low risk of HIV infection (n ≥ 500) Subjects must not have any risk factors for infection with HIV

Exclusion criteria

* Subjects do not meet inclusion criteria

Design outcomes

Primary

MeasureTime frameDescription
Determine clinical performance of Reveal G4At single study visit (one hour)To determine the clinical performance of Reveal G4 with fingerstick and venous whole blood relative to the HIV-1 infected status of the patient

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026