Heart Failure
Conditions
Keywords
atrial fibrillation, heart failure, pacemaker
Brief summary
In this study we will select twenty patients with chronic atrial fibrillation and ventricular dysfunction with permanent cardiac pacemaker indication. We will dosage serum level natriuretic peptides for comparison between conventional and bifocal cardiac pacing.
Detailed description
The target study population will comprise patients with permanent atrial fibrillation with mild or moderate myocardial dysfunction according to the American consensus echocardiography and the classical indication for pacemaker by Brazilian Guidelines for Cardiac Implantable Electronic Devices Guidelines and the American Heart Association. Primary goal: Assess whether resynchronization achieved by bifocal right ventricle pacing has influence on serum levels of natriuretic peptides and whether this could be used as a measure of success. Secondary goal: To compare clinical parameters,compare electrocardiographic parameters (QRS complex stimulated) in ventricular apical position and ventricular bifocal position, assess quality of life by questionnaire Minnesota Living With Heart Failure. Will be implanted pacemaker endocardial bifocal, with placement of a ventricular endocardial electrode in the septal region and another in right ventricle apical, as adopted in the conduct of Pacemaker sector under local anesthesia and sedation. After pacemaker implantation, patients will be randomized in a 1:1 ratio to apical or bifocal stimulation. Patients remained in this mode of stimulation for two months, after which they will be subjected to the following sequence of reviews: Clinical assessment (functional classification of heart failure);assessment of quality of life by the Minnesota Living With Heart Failure Questionnaire, 12-lead electrocardiogram at rest, with measurements of stimulated QRS duration, evaluation of the parameters of the pacemaker, serum level of peptides. At the end of this period of evaluation, patients will undergo cross-over groups, those in apical ventricular pacing will be allocated in the bifocal group and the last one will be allocated to apical ventricular pace. Patients will be retained in the new pacing mode for two months, and at the end of this period will be submitted to clinical, laboratory and assessment of pacemaker evaluation as well. At the end of the study, all patients will be kept in bifocal ventricular pacing, as advocated in the conduct of Pacemaker sector.
Interventions
Patients with pacemaker (Biotronik): an electrode will be implanted in the apical position of the right ventricle and an electrode implanted in the septal position of the right ventricle.The patients will remained in apical stimulation for two months, after that they will be subjected to evaluation. At the end of the evaluation, patients will undergo cross-over groups( bifocal stimulation) and patients will be kept in the new pacing mode for two months when they will be submitted to clinical, laboratory evaluation and assessment of pacemaker
Patients with pacemaker (Biotronik): an electrode will be implanted in the apical position of the right ventricle and an electrode implanted in the septal position of the right ventricle.The patients will remained in bifocal stimulation for two months, after that they will be subjected to evaluation. At the end of the evaluation, patients will undergo cross-over groups( apical stimulation) and patients will be kept in the new pacing mode for two months, when they will be submitted to clinical, laboratory evaluation and assessment of pacemaker
Sponsors
Study design
Eligibility
Inclusion criteria
* Permanent atrial fibrillation with bradycardia and classic indication for permanent pacemaker * mild or moderate ventricular dysfunction (35% \<left ventricle ejection fraction \<55%) of any etiology * Signature of the free and informed consent
Exclusion criteria
* Age \<18 years * left ventricle ejection fraction \> 55% or ≤ 35% * classic indication of cardiac resynchronization therapy by Brazilian Guidelines for Cardiac Implantable Electronic Devices * Patients with left ventricle ejection fraction ≤ 35%, with permanent atrial fibrillation, heart failure with functional class III or IV despite optimal pharmacological treatment and QRS\> 150 ms * Patients with left ventricle ejection fraction ≤ 35%, with permanent atrial fibrillation, heart failure with functional class III or IV despite optimal pharmacological treatment and QRS 120-150 ms with evidence of dyssynchrony by imaging method * Patients with indication for pacemaker when ventricular pacing is essential, left ventricle ejection fraction ≤ 35% and heart failure with functional class III or IV * Refusal to signing the informed consent
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Serum level of natriuretic peptides | 2 months | Assess whether resynchronization achieved by bifocal right ventricle pacing has influence on serum levels of natriuretic peptides and whether this could be used as a marker of success. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Clinical parameters | 2 months | We will compare clinical parameters by New York Heart Association functional classification |
| Electrocardiographic parameters | 2 months | We will compare electrocardiographic parameters (QRS complex stimulated) in ventricular apical position and ventricular bifocal position |
| Assess quality of life | 2 months | We will evaluate quality of life: Minnesota Living with Heart Failure Questionnaire |
Countries
Brazil