Skip to content

Safety and Performance of a GLOBAL Mapping and Ablation Device for the Treatment of Atrial Fibrillation (GLOBAL-AF)

A Prospective, Non-randomized Clinical Study to Assess Safety and Performance of a Device for Global Mapping and Ablation of the Left Atrium for the Treatment of Atrial Fibrillation

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02168972
Acronym
GLOBAL-AF
Enrollment
60
Registered
2014-06-20
Start date
2014-11-30
Completion date
2019-08-31
Last updated
2019-10-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation

Keywords

atrial fibrillation, global, radiofrequency RF ablation, left atrium anatomical and electrophysiological mapping

Brief summary

The purpose of this study is to provide clinical data pertaining to the safety and performance of the Globe® Mapping and Ablation System for treating patients with atrial fibrillation.

Detailed description

Upon successful enrolment, subjects will be scheduled for mapping and radiofrequency (RF) ablation. Cardiac CT imaging, echocardiography and baseline 12-lead ECG will be performed pre-procedure for screening and health assessment. During the procedure the Globe catheter will be delivered via standard femoral vein access and transseptal puncture. Anatomical and electrophysiological mapping of the left atrium (LA) will be followed by RF ablation to achieve pulmonary vein isolation (PVI). Additional lesions will be created as deemed appropriate by the investigator. Intracardiac electrogram mapping will be used to confirm PVI during the procedure. Echocardiography will be performed at discharge to assess cardiac function. Electrocardiograms by 12-lead ECG and 7-day Holter monitoring will be recorded at discharge, and 3, 6 and 12 months after treatment. Follow-up assessments will be performed at discharge, 7 days, and 1, 3, 6 and 12 months after treatment, to track freedom from documented AF and adverse events. Subject-reported AF symptomology and quality of life will also be assessed during follow-up.

Interventions

DEVICEGlobal mapping and ablation device

During the procedure the Globe catheter will be delivered via standard femoral vein access and transseptal puncture. Anatomical and electrophysiological mapping of the LA will be followed by pulmonary vein isolation (PVI) by RF ablation. Additional lesions will be created as deemed appropriate by the investigator.

Sponsors

Kardium Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Patients indicated for ablation, with a documented history of symptomatic paroxysmal atrial fibrillation * Between 18 and 80 years of age, inclusive

Exclusion criteria

* Patients who have contraindications to open heart surgery * Patients from an Intensive Care Unit * Patients requiring concurrent right atrial ablation or who have had previous left atrial ablation * Previous cardiac procedure or known abnormalities that would interfere with device delivery, position, or treatment efficacy * History of a documented thromboembolic event or bleeding abnormalities * Contraindication to anticoagulation therapy * Mental impairment or other conditions, which may not allow patient to understand the nature, significance and scope of the study * Anatomy that would prevent safe and appropriate introduction or delivery of the Globe device into the patient

Design outcomes

Primary

MeasureTime frameDescription
Rate of subjects presenting pre-defined serious adverse events occurring within 7 days of the procedure7 daysRate of subjects presenting with one or more of the following serious adverse events occurring within 7-days of the procedure: * Transient ischemic attack * Cerebrovascular accident * Major bleeding * Cardiac tamponade * Pulmonary vein stenosis * Pericarditis * Myocardial infarction * Diaphragmatic paralysis * Atrio-esophageal fistula * Valvular damage * Phrenic nerve palsy * Intra-procedural device complication requiring open chest or heart surgery * Death

Secondary

MeasureTime frameDescription
Subjects presenting with adverse eventsUp to 1 year* Subjects presenting with primary serious adverse events up to 1 year * Subjects presenting with adverse events or serious adverse events up to 1 year
Acute procedural successIntra-procedurallyAcute device performance in achieving entrance block of the pulmonary veins
Rate of freedom from documented atrial fibrillationBetween 3 months and 1 yearRate of freedom from electrocardiographically documented atrial fibrillation between 3 months and 1 year post-ablation
Change in Quality of life and AF symptom frequency and severity scoresUp to 1 yearChange of quality of life (SF-36) and AF symptom frequency and severity (Bubien et al 1993) questionnaire scores from baseline to 1 year after ablation

Other

MeasureTime frameDescription
Repeat ablation rateUp to 1 yearRate of repeat ablation with a third party catheter or the Globe system
Fluoroscopy time and dose area productIntra-procedurallyFluoroscopy time and dose area product during the procedure
Device functionalityIntra-procedurallyRate of procedures terminated or switched to a third-party ablation catheter due to Globe device failures
Procedure timeIntra-procedurallyProcedure time

Countries

Germany, Switzerland

Outcome results

None listed