Brief summary

Motus Gl is developing a single-use device that attaches to a standard colonoscope, thereby integrating colon cleansing, screening and treatment into one procedure. The device creates turbulence within the colon using water jets. The colon's fecal fluids are evacuated by the system.

Detailed description

63 eligible subjects who are allocated for a diagnostic screening colonoscopy were enrolled in the study. The assignment of the level of the bowel preparation agent was according to the physician decision. Following preparation, enrolled subjects were intubated and cleansed using a standard colonoscope with the Motus GI CleanUp device attached to it. At the end of the procedure, subjects were followed through discharge and at 48 hours post procedure for occurrence of adverse events. 40 subjects were enrolled under protocol Rev 1.0 used Motus GI CleanUp System Rev 1.0 31 subjects were enrolled under protocol Rev 2 used Motus GI CleanUp System Rev 1.5, due to improvement made to the study device including the following: 1. One head that irrigates and evacuates instead of two heads 2. Elimination of the grinding mechanism and the motor to reduce the pipes' diameters while keeping the same flow rate. 3. System adjustment to the above changes including updated software version.

Interventions

DEVICEMotus Gl CleanUp System

Sponsors

Motus GI Medical Technologies Ltd
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
50 Years to 69 Years
Healthy volunteers
Yes

Inclusion criteria

* Subjects in the age range of 50-69 years * Subjects who are considered for routine screening colonoscopy * Subjects with BMI within the range of 18.5-30 * Subject is willing to sign informed consent form

Exclusion criteria

* History of G diseases or history of Colorectal cancer (personal or family) * Previous major abdominal surgeries * Medical status ASA grater or equal to 3 * Acute Gl symptoms, such as bleeding, unexplained weight loss, inflammatory bowel disease (lBD). * Patients taking anticoagulants (e.g., Coumadin, Heparin, Clopidrogrel) * Life-threatening condition * Subjects who are unable or unwilling to cooperate with study procedures * Severe Diverticula

Design outcomes

Primary

MeasureTime frameDescription
Mean Score of Boston Bowel Preparation Scale (BBPS) Index Prior and After the Use of MotusGI CleanUp Systemduring colonoscopy procedure after cleansing with CleanUp SystemHuman colon has 3 segments and each segment can be scored 0 (unprepared colon) - 3 (clean colon). average of all colon segments BBPS score after the use of MotusGI CleanUp System

Countries

Spain

Participant flow

Recruitment details

The recruitment was done in two phases: Phase 1- under protocol Rev 1.0 used MotusGi CleanUp System Rev 1.0 , study period Aug- Jan 2012. 40 subjects enrolled. Phase 2- under protocol Rev 2.0 used MotusGi CleanUp System Rev 1.5 , study period Jul-Oct 2013.31 subjects enrolled.

Participants by arm

ArmCount
Colonoscopy With MotusGi CleanUp System Rev 1.0
subjects indicated for colonoscopy procedure with CleanUp System Rev 1.0 , enrolled under protocol Rev 1.0 Motus Gl CleanUp System
34
Colonoscopy With MotusGi CleanUp System Rev 1.5
subjects indicated for colonoscopy procedure with CleanUp System Rev 1.5 , enrolled under protocol Rev 2.0 Motus Gl CleanUp System
29
Total63

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudyPhysician Decision62

Baseline characteristics

CharacteristicColonoscopy With MotusGi CleanUp System Rev 1.0Colonoscopy With MotusGi CleanUp System Rev 1.5Total
Age, Continuous55 years
STANDARD_DEVIATION 3.8
53 years
STANDARD_DEVIATION 4.1
54 years
STANDARD_DEVIATION 4
Sex: Female, Male
Female
13 Participants14 Participants27 Participants
Sex: Female, Male
Male
21 Participants15 Participants36 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 400 / 31
other
Total, other adverse events
17 / 4017 / 31
serious
Total, serious adverse events
0 / 400 / 31

Outcome results

Primary

Mean Score of Boston Bowel Preparation Scale (BBPS) Index Prior and After the Use of MotusGI CleanUp System

Human colon has 3 segments and each segment can be scored 0 (unprepared colon) - 3 (clean colon). average of all colon segments BBPS score after the use of MotusGI CleanUp System

Time frame: during colonoscopy procedure after cleansing with CleanUp System

Population: the mean and standard deviation of the average score after cleansing the colon using the Motus CleanUp System

ArmMeasureValue (MEAN)Dispersion
Colonoscopy With MotusGi CleanUp System Rev 1.0Mean Score of Boston Bowel Preparation Scale (BBPS) Index Prior and After the Use of MotusGI CleanUp System2.9 units on a scaleStandard Deviation 0.4
Colonoscopy With MotusGi CleanUp System Rev 1.5Mean Score of Boston Bowel Preparation Scale (BBPS) Index Prior and After the Use of MotusGI CleanUp System2.9 units on a scaleStandard Deviation 0.2

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026