Posture and Mobility of the Upper Quadrant
Conditions
Keywords
Smartphone measurements, Orientation, Range of motion, Median nerve neurodynamic test, Posture, Thoracic spine, Shoulder girdle
Brief summary
This study aims to investigate posture-mobility associations in the upper quadrant by means of smartphone measurements
Detailed description
One purpose of this study is to measure the magnitude of the thoracic kyphosis, thoracic spine extension, and side-to-side differences in scapular protraction and elbow extension range of motion during the median nerve neurodynamic test through a smartphone (iPhone 4, app Compass, iOS 7.1.1), and to assess the intrarater agreement parameters. Another purpose is to assess associations between thoracic kyphosis, thoracic spine extension, scapular protraction and the resting length of the pectoralis minor muscle through smartphone, photographs and tape measurements.
Interventions
None listed
Sponsors
Study design
Eligibility
Inclusion criteria
* Age \> 18 years old * Normal mobility in the joints of the upper quadrant
Exclusion criteria
* complaints in the upper quadrant over the past 3 months * significant deformities in the upper quadrant * leg length discrepancy \> 1.5 cm
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Elbow extension range of motion | At the time of the assessment | Elbow extension range of motion (in degrees) during the median nerve neurodynamic test is measured by means of a smartphone (iPhone 4, app Compass, iOS 7.1.1) |
| Thoracic kyphosis orientation | At the time of the assessment | The magnitude of the thoracic kyphosis (in degrees) in the standing upright position is measured by means of a smartphone (iPhone 4, app Compass, iOS 7.1.1) |
| Thoracic spine extension range of motion | At the time of the assessment | The extension range of motion of the thoracic spine (in degrees) in the standing upright position is measured by means of a smartphone (iPhone 4, app Compass, iOS 7.1.1) |
| Scapular protraction orientation | At the time of the assessment | The magnitude of the scapular protraction (in degrees) in the standing upright position with the arms at rest is measured by means of a smartphone (iPhone 4, app Compass, iOS 7.1.1) |
| Pectoralis minor muscle resting length | At the time of the assessment | Pectoralis minor muscle resting length (in centimeters) with the arms at rest is measured by means of a measuring tape in the standing upright position |
Countries
Portugal