Accuracy of Two CGM Systems Tested Simultaneously in Ambulatory Patients With Type 1 Diabetes

Accuracy of Two CGM Systems Tested Simultaneously in Ambulatory Patients With Type 1 Diabetes

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02159638
Enrollment
38
Registered
2014-06-10
Start date
2013-05-31
Completion date
2014-09-01
Last updated
2017-12-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Blood Glucose, Diabetes Mellitus, Type 1

Keywords

Diabetes Mellitus, Diabetes Mellitus, Type 1, Diabetes Mellitus, Insulin-Dependent, Endocrine System Diseases, Blood glucose, Blood Glucose, Self-Monitoring

Brief summary

Continuous glucose monitoring (CGM) is a tool used in the treatment of patients with type 1 diabetes. A continuous glucose monitor (CGM) is a subcutaneous tissue sensor, which provides a tissue fluid glucose measurement every 1 to 5 minutes. Since CGM measure the glucose level by a sensor in subcutaneous tissue, there is uncertainty in the estimation of blood glucose levels. The accuracy of a certain CGM system can be assessed by comparing the glucose levels estimated by CGM with measured glucose levels in plasma. In the current study, we will compare the accuracy of the 2 CGM systems available on the market for clinical use in patients with type 1 diabetes. The aim of the current study is to evaluate effectiveness, safety and treatment satisfaction with 2 different CGM systems among adult type 1 diabetic patients.

Detailed description

Each study patient will have both subcutaneous tissue CGM sensors inserted. Each sensor will produce a maximum of 1,440 tissue fluid glucose measurements per 24 hours and 8,460 measurements during the 6 days in study. The plan is to study 36 to 50 ambulatory patients during the hole study period. The two CGM data sets (DexCom4G and Medtronic Enlite) will be compared to each other and the time-matched reference blood glucose measurements. The HemoCue Analyser- venous blood and finger-stick blood in cuvette, will be used to measure the concentration of glucose. Each ambulatory patient will sample capillary blood and measure the concentration of glucose 6 to 10 times per day for max 6 days. The concentration of finger-stick capillary blood glucose will be measured using the HemoCue meter in their daily living and additionally a HemoCue Analyser at research visits using a lancet. Each patient will be admitted to the clinical research unit (CRU) for 7 measurements of venous samples at two occasions: on day 1-3 and 4-6 of the study with an interval of at least 15 minutes. An intravenous catheter will be inserted to facilitate blood sample acquisition each of these days of study. Three capillary finger-stick blood will be sampled at these 2 occasions, 1 at the first venous measurement (one day of days 1-3) and one at the last venous sample (one day of days 4-6). Blood sample acquisition and handling will be standardized to minimize pre-analytical error. The sensor insertion sites will be observed to detect bleeding, inflammation and infection of the skin or subcutaneous tissue. Insertion sites will be photographed if any abnormal findings exist at the end of the study for the individual patient. The subjects will record self monitoring of blood glucose (SMBG), meal, and activity data in a written diary.

Interventions

DEVICEGuardian Enlite sensor

Sensor insertion

Sensor insertion

Sponsors

Vastra Gotaland Region
Lead SponsorOTHER_GOV

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Type 1 diabetes 2. Adult patients, age 18 or older and \<75 years. 3. Written Informed Consent

Exclusion criteria

1. Pregnancy 2. Patients with severe cognitive dysfunction or other disease which makes CGM use difficult. 3. Patients requiring continuous use of paracetamol. Paracetamol must not have been used the week before the study and shall not be used during the duration because it disturbs the interpretation of blood glucose levels estimated by the DexCom4G. However, other pain killers can be used throughout the study period. 4. Current CGM use 5. History of allergic reaction to any of the CGMS materials or adhesives in contact with the skin. 6. History of allergic reaction to chlorhexidine or alcohol anti-septic solution. 7. Abnormal skin at the anticipated glucose sensor attachment sites (excessive hair, burn, inflammation, infection, rash, and/or tattoo).

Design outcomes

Primary

MeasureTime frameDescription
Difference between the two CGM systems compared to capillary glucose value6 daysPrimary efficacy analysis will be investigating whether there is a statistically significant difference between the two CGM systems with respect to mean absolute relative difference (MARD) of estimated capillary glucose value over the whole study period.

Secondary

MeasureTime frameDescription
the accuracy of the 2 CGM systems during each studied time interval (day 1-3 and day 4-6)day 1-3 and day 4-6Accuracy of all estimated capillary glucose values (registered both during days 1-3 and days 4-6) of DexCom 4G system (DexCom sensor) vs Guardian Real-Time system (Enlite sensor) system compared to the capillary reference blood glucose measured with HemoCue.
the accuracy of the 2 CGM systems for hypoglycaemia6 daysAccuracy in estimating capillary glucose levels \<4 registered both during days 1-3 and days 4-6 of DexCom 4G system (DexCom sensor) vs Guardian Real-Time system (Enlite sensor) system compared to the capillary reference blood glucose measured with HemoCue(hypo, normoglycaemia and hyperglycaemia)
the accuracy of the 2 CGM systems for normoglycaemia6 daysAccuracy in estimating capillary glucose levels of 4.0-10.0 mmol/l registered both during days 1-3 and days 4-6 of DexCom 4G system (DexCom sensor) vs Guardian Real-Time system (Enlite sensor) system compared to the capillary reference blood glucose measured with HemoCue
the accuracy of the 2 CGM systems for hyperglycaemia6 daysAccuracy in estimating capillary glucose levels \>14.0 mmol/l registered both during days 1-3 and days 4-6 of DexCom 4G system (DexCom sensor) vs Guardian Real-Time system (Enlite sensor) system compared to the capillary reference blood glucose measured with HemoCue
Evaluation of two CGM systems from questionnaireday 6Evaluation of DexCom 4G system (DexCom sensor) vs Guardian Real-Time system (Enlite sensor) from questionnaire