Endotracheal Intubation, Individualized Depth of Endotracheal Intubation
Conditions
Brief summary
1. Airway length from the medial incisor to carina is divided into four segments ; the length from medial incisor to mouth angle, mouth angle to epiglottis, epiglottis to vocal cords and vocal cords to carina. 2. Determining the mean length of each segments with the direct laryngoscope, videolaryngoscope and fiberoptic bronchoscope at the time of endotracheal intubation. 3. Making a new formula to determine the proper individualized depth of intubation on the basis of the length of segments 4. Virtual experiment : comparing the new formula with conventional method of determining the depth of endotracheal intubation
Interventions
None listed
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients who are scheduled to take general anesthesia with endotracheal intubation
Exclusion criteria
* Patients undergoing general anesthesia with face mask ventilation or laryngeal mask airway
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Comparison of Airway Length Between Male and Female | Endotracheal intubation time | Airway length is defined the distance from medial incisor to carina. It is divided into four parts. It is medial incisor to mouth angle, mouth angle to epiglottis tip, epiglottis tip to vocal cords and vocal cords to carina. |
| Airway Length vs Height in Male | Endotracheal intubation time | — |
| Airway Length vs Height in Female | Endotracheal intubation time | — |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Comparison Between Conventional Method and Touch and Read Method for Risk Group of Male | Endotracheal intubation time | Normal group is defined as the patients whose airway length from medial incisor to carina is below 25cm. Conventional method : depth of intubation is 23cm at the medial incisor for male. Touch and read method : depth of intubation is calculated as follow : length from mouth angle to epiglottis tip plus 12.5cm for male. |
| Comparison Between Conventional Method and Touch and Read Method for Normal Group of Female | Endotracheal intubation time | Normal group is defined as the patients whose airway length from medial incisor to carina is over 23cm. Conventional method : depth of intubation is 21cm at the medial incisor for female. Touch and read method : depth of intubation is calculated as follow : length from mouth angle to epiglottis tip plus 11.5cm for female. |
| Comparison Between Conventional Method and Touch and Read Method for Normal Group of Male | Endotracheal intubation time | Normal group is defined as the patients whose airway length from medial incisor to carina is over 25cm. Conventional method : depth of intubation is 23cm at the medial incisor for male. Touch and read method : depth of intubation is calculated as follow : length from mouth angle to epiglottis tip plus 12.5cm for male. |
| Comparison Between Conventional Method and Touch and Read Method for Risk Group of Female | Endotracheal intubation time | Risk group is defined as the patients whose airway length from medial incisor to carina is below 23cm. Conventional method : depth of intubation is 21cm at the medial incisor for female. Touch and read method : depth of intubation is calculated as follow : length from mouth angle to epiglottis tip plus 11.5cm for female. |
Countries
South Korea
Participant flow
Participants by arm
| Arm | Count |
|---|---|
| Touch and Read Group(Male) This is a virtual experiment based on the anthropometry of the airway length. We defined the conventional group as patients who are intubated on the depth of 25cm for male and 23 cm fo female from the medial incisor virtually.
Touch and read group : Depth of intubation was determined on the measurement of the airway length of each patient. In touch and read group, the depth of intubation was determined by the sum of the length from the mouth angle to epiglottis tip, the length from the epiglottis tip to vocal cords and 8cm for the endotracheal tube #7.0. Length from the mouth angle to epiglottis tip is determined at the time of intubation with specially scaled endotracheal tube. | 69 |
| Touch and Read Group(Female) female | 107 |
| Total | 176 |
Withdrawals & dropouts
| Period | Reason | FG000 |
|---|---|---|
| Overall Study | Invisible vocal cords | 5 |
Baseline characteristics
| Characteristic | Touch and Read Group(Male) | Touch and Read Group(Female) | Total |
|---|---|---|---|
| Age, Categorical <=18 years | 0 Participants | 0 Participants | 0 Participants |
| Age, Categorical >=65 years | 7 Participants | 25 Participants | 32 Participants |
| Age, Categorical Between 18 and 65 years | 62 Participants | 82 Participants | 144 Participants |
| Sex: Female, Male Female | 0 Participants | 107 Participants | 107 Participants |
| Sex: Female, Male Male | 69 Participants | 0 Participants | 69 Participants |
Adverse events
| Event type | EG000 affected / at risk | EG001 affected / at risk |
|---|---|---|
| deaths Total, all-cause mortality | — / — | — / — |
| other Total, other adverse events | 0 / 71 | 0 / 110 |
| serious Total, serious adverse events | 0 / 71 | 0 / 110 |
Outcome results
Airway Length vs Height in Female
Time frame: Endotracheal intubation time
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Airway Length for Male | Airway Length vs Height in Female | Mouth angle to carina | 23.2 Centimeters | Standard Deviation 1.5 |
| Airway Length for Male | Airway Length vs Height in Female | Mouth angle to epiglottis tip | 8.3 Centimeters | Standard Deviation 1 |
| Airway Length for Male | Airway Length vs Height in Female | Epglottis tip to vocal cords | 3.6 Centimeters | Standard Deviation 0.9 |
| Airway Length for Male | Airway Length vs Height in Female | Vocal cords to carina | 11.2 Centimeters | Standard Deviation 1.2 |
| Airway Length for Male | Airway Length vs Height in Female | Female height | 156.4 Centimeters | Standard Deviation 5.2 |
Airway Length vs Height in Male
Time frame: Endotracheal intubation time
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Airway Length for Male | Airway Length vs Height in Male | Mouth angle to carina | 25.5 Centimeters | Standard Deviation 1.8 |
| Airway Length for Male | Airway Length vs Height in Male | Mouth angle to epiglottis tip | 9.1 Centimeters | Standard Deviation 1 |
| Airway Length for Male | Airway Length vs Height in Male | Epiglottis tip to vocal cords | 4.4 Centimeters | Standard Deviation 0.9 |
| Airway Length for Male | Airway Length vs Height in Male | Vocal cords to carina | 11.9 Centimeters | Standard Deviation 1.3 |
| Airway Length for Male | Airway Length vs Height in Male | Male height | 168 Centimeters | Standard Deviation 7.4 |
Comparison of Airway Length Between Male and Female
Airway length is defined the distance from medial incisor to carina. It is divided into four parts. It is medial incisor to mouth angle, mouth angle to epiglottis tip, epiglottis tip to vocal cords and vocal cords to carina.
Time frame: Endotracheal intubation time
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Airway Length for Male | Comparison of Airway Length Between Male and Female | Mouth angle to epiglottis tip | 9.1 Centimeters | Standard Deviation 1 |
| Airway Length for Male | Comparison of Airway Length Between Male and Female | Vocal cords to carina | 11.9 Centimeters | Standard Deviation 1.3 |
| Airway Length for Male | Comparison of Airway Length Between Male and Female | Epiglottis tip to vocal cords | 4.4 Centimeters | Standard Deviation 0.9 |
| Airway Length for Male | Comparison of Airway Length Between Male and Female | Medial incisor to carina | 26.4 Centimeters | Standard Deviation 1.9 |
| Airway Length for Male | Comparison of Airway Length Between Male and Female | Medial incisor to mouth angle | 0.9 Centimeters | Standard Deviation 0.5 |
| Airway Length of Female | Comparison of Airway Length Between Male and Female | Medial incisor to carina | 24.2 Centimeters | Standard Deviation 1.5 |
| Airway Length of Female | Comparison of Airway Length Between Male and Female | Medial incisor to mouth angle | 1.1 Centimeters | Standard Deviation 0.5 |
| Airway Length of Female | Comparison of Airway Length Between Male and Female | Mouth angle to epiglottis tip | 8.3 Centimeters | Standard Deviation 1 |
| Airway Length of Female | Comparison of Airway Length Between Male and Female | Epiglottis tip to vocal cords | 3.6 Centimeters | Standard Deviation 0.9 |
| Airway Length of Female | Comparison of Airway Length Between Male and Female | Vocal cords to carina | 11.2 Centimeters | Standard Deviation 1.2 |
Comparison Between Conventional Method and Touch and Read Method for Normal Group of Female
Normal group is defined as the patients whose airway length from medial incisor to carina is over 23cm. Conventional method : depth of intubation is 21cm at the medial incisor for female. Touch and read method : depth of intubation is calculated as follow : length from mouth angle to epiglottis tip plus 11.5cm for female.
Time frame: Endotracheal intubation time
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Airway Length for Male | Comparison Between Conventional Method and Touch and Read Method for Normal Group of Female | Tube tip to carina | 3.8 Centimeters | Standard Deviation 1 |
| Airway Length for Male | Comparison Between Conventional Method and Touch and Read Method for Normal Group of Female | Vocal cords to cuff | 1.8 Centimeters | Standard Deviation 0.9 |
| Airway Length of Female | Comparison Between Conventional Method and Touch and Read Method for Normal Group of Female | Tube tip to carina | 3.8 Centimeters | Standard Deviation 1 |
| Airway Length of Female | Comparison Between Conventional Method and Touch and Read Method for Normal Group of Female | Vocal cords to cuff | 1.9 Centimeters | Standard Deviation 1 |
Comparison Between Conventional Method and Touch and Read Method for Normal Group of Male
Normal group is defined as the patients whose airway length from medial incisor to carina is over 25cm. Conventional method : depth of intubation is 23cm at the medial incisor for male. Touch and read method : depth of intubation is calculated as follow : length from mouth angle to epiglottis tip plus 12.5cm for male.
Time frame: Endotracheal intubation time
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Airway Length for Male | Comparison Between Conventional Method and Touch and Read Method for Normal Group of Male | Tube tip to carina | 4.1 Centimeters | Standard Deviation 1.2 |
| Airway Length for Male | Comparison Between Conventional Method and Touch and Read Method for Normal Group of Male | Vocal cords to cuff | 2.3 Centimeters | Standard Deviation 0.8 |
| Airway Length of Female | Comparison Between Conventional Method and Touch and Read Method for Normal Group of Male | Tube tip to carina | 4.4 Centimeters | Standard Deviation 1.2 |
| Airway Length of Female | Comparison Between Conventional Method and Touch and Read Method for Normal Group of Male | Vocal cords to cuff | 2.0 Centimeters | Standard Deviation 1 |
Comparison Between Conventional Method and Touch and Read Method for Risk Group of Female
Risk group is defined as the patients whose airway length from medial incisor to carina is below 23cm. Conventional method : depth of intubation is 21cm at the medial incisor for female. Touch and read method : depth of intubation is calculated as follow : length from mouth angle to epiglottis tip plus 11.5cm for female.
Time frame: Endotracheal intubation time
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Airway Length for Male | Comparison Between Conventional Method and Touch and Read Method for Risk Group of Female | Tube tip to carina | 1.2 Centimeters | Standard Deviation 1 |
| Airway Length for Male | Comparison Between Conventional Method and Touch and Read Method for Risk Group of Female | Vocal cords to cuff | 2.7 Centimeters | Standard Deviation 0.9 |
| Airway Length of Female | Comparison Between Conventional Method and Touch and Read Method for Risk Group of Female | Tube tip to carina | 1.9 Centimeters | Standard Deviation 1.1 |
| Airway Length of Female | Comparison Between Conventional Method and Touch and Read Method for Risk Group of Female | Vocal cords to cuff | 2.0 Centimeters | Standard Deviation 0.9 |
Comparison Between Conventional Method and Touch and Read Method for Risk Group of Male
Normal group is defined as the patients whose airway length from medial incisor to carina is below 25cm. Conventional method : depth of intubation is 23cm at the medial incisor for male. Touch and read method : depth of intubation is calculated as follow : length from mouth angle to epiglottis tip plus 12.5cm for male.
Time frame: Endotracheal intubation time
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Airway Length for Male | Comparison Between Conventional Method and Touch and Read Method for Risk Group of Male | Tube tip to carina | 0.7 Centimeters | Standard Deviation 1.4 |
| Airway Length for Male | Comparison Between Conventional Method and Touch and Read Method for Risk Group of Male | Vocal cords to cuff | 3.5 Centimeters | Standard Deviation 1.4 |
| Airway Length of Female | Comparison Between Conventional Method and Touch and Read Method for Risk Group of Male | Tube tip to carina | 2.0 Centimeters | Standard Deviation 1.2 |
| Airway Length of Female | Comparison Between Conventional Method and Touch and Read Method for Risk Group of Male | Vocal cords to cuff | 2.3 Centimeters | Standard Deviation 1.1 |