Skip to content

Reduction of Fluoroscopy Exposure During Atrial Fibrillation Ablation

Atrial Fibrillation Ablation Facilitated by Fluoroscopy Image Integrated 3-dimentional Electroanatomical Mapping System

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02137798
Acronym
AF-FII
Enrollment
80
Registered
2014-05-14
Start date
2014-03-31
Completion date
2014-09-30
Last updated
2014-10-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation

Keywords

fluoroscopy exposure, paroxysmal atrial fibrillation Ablation, fluoroscopy, Atrial Fibrillation Ablation

Brief summary

To evaluate reduction of fluoroscopy time/dosis and safety of atrial fibrillation ablation in patients with paroxysmal atrial fibrillation using fluoroscopy image integrated 3-dimentional electroanatomical mapping system, comparing to using 3-dimentional electroanatomical mapping system without fluoroscopy image integration

Detailed description

The novel fluoroscopic image integrated 3-dimentional electroanatomical mapping system is designed for minimizing the exposure to X-ray for physician, staff and patients. This randomized single-center study is to evaluate the reduction on fluoroscopy levels (time and dosis) in catheter interventional treatment of symptomatic, antiarrhythmic refractory paroxysmal atrial fibrillation using fluoroscopic image integrated 3-dimentional electroanatomical mapping system, comparing with using 3-dimentional electroanatomical mapping system without fluoroscopic image integration. Patients with documented paroxysmal atrial fibrillation, who are going to receive a catheter interventional treatment to atrial fibrillation, will be randomized (1:1) into two groups after signing an informed consent. Group 1 (CARTOUNIVU): using fluoroscopic image integrated 3-dimentional electroanatomical mapping system. Group 2 (CARTO3): using 3-dimentional electroanatomical mapping system without fluoroscopic image integration. The ablation strategies in both study groups are the same, including circumferential isolation of ipsilateral pulmonary veins (PV) and voltage map guided substrate modification. According to the randomization, the ablation procedure will be performed with or without fluoroscopic image integration. The primary endpoint of this study is the evaluation of reduction on fluoroscopy levels (fluoroscopy time and dosis) during atrial fibrillation ablation procedure. Secondary endpoints include complete isolation of the pulmonary veins, completely bidirectional block of linear ablation lines, total procedure time, ablation-related complications.

Interventions

Radio-frequency atrial fibrillation catheter ablation includes circumferential PV isolation and voltage-map guided substrate modification, which means low voltage zone (amplitude \< o.5 mV) will also be ablated.

Sponsors

Biosense Webster, Inc.
CollaboratorINDUSTRY
Technische Universität Dresden
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* documented atrial fibrillation in the 12-lead ECG or Holter ECG * Paroxysmal symptomatic atrial fibrillation * Ineffectiveness of antiarrhythmic medication ( at least 1 medication ) * Age 18-75 years * left atrial diameter \<60 mm ( Transesophageal Echocardiography, parasternal ) * A signed consent form

Exclusion criteria

* Reversible etiology of atrial fibrillation * Pregnancy * Women of childbearing potential without a negative pregnancy test within 48 hours prior to the ablation procedure * Intracardiac thrombus * Contraindication to anticoagulation * Thromboembolic event in the last 6 months * Previous left atrial ablation

Design outcomes

Primary

MeasureTime frameDescription
Fluoroscopy time for each step of atrial fibrillation ablation procedure1 day ( at the end of each step of atrial fibrillation ablation procedure)Fluoroscopy time will be recorded at the end of each step of atrial fibrillation ablation, including femoral vein puncture, placement of catheters, transseptal puncture, system registration, reconstruction of left atrium, PV-Angiography, acquirement of voltage map, PV-isolation, confirmation of complete PV isolation and linear ablations.
Fluoroscopy doses for each step of atrial fibrillation ablation procedure1 day ( at the end of each step of atrial fibrillation ablation procedure)Fluoroscopy doses will be recorded at the end of each step of atrial fibrillation ablation, including femoral vein puncture, placement of catheters, transseptal puncture, system registration, reconstruction of left atrium, PV-Angiography, acquirement of voltage map, PV-isolation, confirmation of complete PV isolation and linear ablations.

Secondary

MeasureTime frameDescription
Number of patients with adverse events as a measure of safetyAll patients will be followed for the duration of hospital stay for acute complications, an expected average of 3 days.Perforation, tamponed, phrenic nerve injury and oesophagus injury (patients will be screened for oesophagus injury for a month after atrial fibrillation ablation), etc.
Number of patients with a failure of reaching endpoints of procedure as a measure of efficacy1 day ( at the end of each step of atrial fibrillation ablation procedure)number of pulmonary veins/linear ablation lines has not been completely isolated/blocked at the end of the AF ablation
Total time of atrial fibrillation ablation procedure as a measure of efficacyup to 24 hoursprocedure time (minute)

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026