Skip to content

Safety, Tolerability and Efficacy for CGF166 in Patients With Unilateral or Bilateral Severe-to-profound Hearing Loss

A Three-part, Multicenter, Open Label, Single Dose Study to Assess the Safety, Tolerability, and Efficacy of Intra Labyrinthine (IL) CGF166 in Patients With Severe-to-profound Hearing Loss

Status
Completed
Phases
Phase 1Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02132130
Enrollment
22
Registered
2014-05-07
Start date
2014-06-23
Completion date
2019-12-09
Last updated
2021-10-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Unilateral Severe to Profound Hearing Loss OR Bilateral Severe to Profound Hearing Loss

Keywords

gene therapy, unilateral hearing loss, bilateral hearing loss, balance, vestibular, cochlear implant, hearing restoration

Brief summary

The goal of the study was to evaluate the safety, tolerability, and the potential ability of CGF166 delivered through IL-infusion to improve hearing. CGF166 is a recombinant adenovirus 5 (Ad5) vector containing a cDNA encoding the human Atonal transcription factor (Hath1).

Detailed description

This study evaluated the safety, tolerability, and potential efficacy of CGF166 and the associated delivery procedures in patients with severe-to-profound unilateral or bilateral hearing loss. Eligible patients were required to have documented, non-fluctuating hearing loss.

Interventions

DRUGCGF166

CGF166 is a recombinant adenovirus 5 (Ad5) vector containing the human Atonal transcription factor (Hath1) cDNA for administration via intra-labyrinthine infusion

Sponsors

Novartis Pharmaceuticals
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

For all Parts A, B and C of the study, Inclusion criteria: 1. Written informed consent must be obtained before any assessment is performed. 2. For all Parts A, B and C of the study, male or female patients, 18 to 75 years old, inclusive, with severe-to-profound bilateral hearing loss or unilateral hearing loss with intact vestibular function in the nonoperative ear. Non-fluctuating severe-to-profound hearing loss is required for the study ear and is defined as: * PTA within 10 dB of the PTA obtained at least 11 months previously. * Word recognition within 20% of previous test at least 11 months previously 3. Candidate ear (study ear): Minimal residual hearing based on the pure tone average of 0.5, 1, 2, and 4 kHz thresholds of ≤110 dB HL 4. Candidate ear (study ear): Pure tone audiometric thresholds of ≥50 dB HL for each testable octave frequency of 0.125 and 0.250 kHz, ≥70 dB HL for each testable octave frequency from 0.5 through 8 kHz and sentence recognition scores ≤50% at screening. 6\. Patients with intact vestibular function in at least one ear (non-study ear) as measured by vestibular evoked myogenic potential (VEMP) 7. Able to communicate well with the investigator, to understand and comply with the requirements of the study 8. MRI scan within 6 months or at screening to confirm suitability for inner ear surgery 9. Patients must weigh at least 40 kg to participate in the study, and must have a body mass index (BMI) \<45 kg/m2. BMI = Body weight (kg) / \[Height (m)\]2

Exclusion criteria

1. Patients with hearing loss caused by genetic/developmental disorders, e.g., cochlea aplasia 2. Patients with existing conductive hearing loss or mixed hearing loss as judged by the Principal Investigator following a thorough review of all of the trial hearing assessments; 3. Patients with a history of cochlear implant in the study ear 4. Hearing loss due to any other cause that would not be expected to respond to hair cell regeneration, for example mechanical trauma or central auditory lesions or lack of an auditory nerve 5. Patients who will require ototoxic drugs as routine therapy over the course of the study, for example cystic fibrosis patients 6. Any contraindication to the planned surgery or anesthesia as determined by the surgeon or anesthesiologist 7. Previous surgery in the study ear 8. Any otological history, such as chronic otitis, cholesteatoma, tympanic membrane perforation, that suggests poor candidacy for cochlear implant or inner ear surgery or suggests potential interference with study auditory or vestibular function tests 9. Pregnant women 10. Abnormal vital signs and/or ECG that suggest potential contraindication for planned study anesthesia 11. Past serious adverse reaction to anesthesia 12. Meniere's Disease 13. History of radiation therapy to the head and neck 14. Participation in a clinical trial within the last 30 days 15. Immunocompromised patients, as judged by the investigators based on patient history, physical exam and CBC

Design outcomes

Primary

MeasureTime frameDescription
Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study VisitWeek 52Summary of change from baseline in Non-treated ear's pure tone audiometry air conduction threshold by frequency for last study visit is presented in table below.
Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDays 29, 57, 85, 113, 141, 169, 358, 537, 600Summary of pure tone audiometry air conduction thresholds at frequency 0.125 KHz
Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDays 29, 57, 85, 113, 141, 169, 358,537, EoSSummary of pure tone audiometry bone conduction thresholds by time and frequency 0.250 KHz
Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study VisitWeek 52Summary of change from baseline in pure tone audiometry air conduction threshold by frequency for last study visit is presented in table below.
Number of Participants With Adverse Eventsweek 52AE tables are below in the Adverse Events section of this report.
Number of Adverse Eventsweek 52AE tables are below in the Adverse Events section of this report.

Secondary

MeasureTime frameDescription
Number of Participants With Response in Vestibular Function in Treated Ear Compared to Pretreatment Values24 monthsResponse in vestibular assessments (Head impulse test (HIT), Vestibular evoked myogenic potential (VEMP), Subjective visual vertical (SVV)) to CGF166.
Number of Participants With Changes in Auditory Functions (Speech Recognition) and Vestibular Functions Before and After IL Infusion of CGF166 Between the Study Ear and the Contralateral Ear24 monthsClinically signficant speech recognition improvement (word and/or sentence) following treatment. The individual auditory assessments were speech audiometry, AzBio sentence test, consonant nucleus consonant test, word recognition, Hearing-in-Noise Test (HINT), Brainstem auditory evoked response evaluations (BAER), Distortion product otoacoustic emission testing (DPOE) and shoebox audiometry.
Number of Participants With Change in Brainstem Auditory Evoked Responses (BAER) Compared to Pretreatment Values24 monthsBAERs was assessed with standard techniques for clinically significant threshold improvements compared to baseline levels.

Countries

United States

Participant flow

Recruitment details

A total of 22 subjects were enrolled in the study, of which 19 completed the study and 2 subjects discontinued due to lost to follow-up and 1 subject withdrew consent

Pre-assignment details

Safety analysis set comprised all subjects who received study drug and with no protocol deviations having relevant impact on safety.

Participants by arm

ArmCount
CGF166 Dose 20 μL
single dose volume #1
3
CGF166 Dose 30 μL
single dose volume #2
12
CGF166 Dose 40 μL
single dose volume #3
4
CGF166 Dose 60 μL
single dose volume #4
3
Total22

Withdrawals & dropouts

PeriodReasonFG000FG001FG002FG003
Overall StudyLost to Follow-up0200
Overall StudyWithdrawal by Subject0001

Baseline characteristics

CharacteristicCGF166 Dose 20 μLCGF166 Dose 30 μLCGF166 Dose 40 μLCGF166 Dose 60 μLTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
0 Participants3 Participants1 Participants1 Participants5 Participants
Age, Categorical
Between 18 and 65 years
3 Participants9 Participants3 Participants2 Participants17 Participants
Age, Continuous39.0 Years
STANDARD_DEVIATION 17.35
50.8 Years
STANDARD_DEVIATION 15.2
52.8 Years
STANDARD_DEVIATION 13.4
51.3 Years
STANDARD_DEVIATION 19.3
49.6 Years
STANDARD_DEVIATION 15.16
Race/Ethnicity, Customized
Asian
0 Participants1 Participants0 Participants0 Participants1 Participants
Race/Ethnicity, Customized
Caucasian
3 Participants10 Participants4 Participants3 Participants20 Participants
Race/Ethnicity, Customized
Other
0 Participants1 Participants0 Participants0 Participants1 Participants
Sex: Female, Male
Female
2 Participants3 Participants1 Participants1 Participants7 Participants
Sex: Female, Male
Male
1 Participants9 Participants3 Participants2 Participants15 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
EG002
affected / at risk
EG003
affected / at risk
deaths
Total, all-cause mortality
0 / 30 / 120 / 40 / 3
other
Total, other adverse events
3 / 36 / 124 / 43 / 3
serious
Total, serious adverse events
0 / 30 / 120 / 40 / 3

Outcome results

Primary

Number of Adverse Events

AE tables are below in the Adverse Events section of this report.

Time frame: week 52

Population: The Safety Analysis Set was comprised of all subjects that received study drug and with no protocol deviations having relevant impact on safety.

ArmMeasureValue (NUMBER)
CGF166 Dose 20 μLNumber of Adverse Events9 Adverse events
CGF166 Dose 30 μLEdit Single Dose Volume #2Number of Adverse Events16 Adverse events
CGF166 Dose 40 μLNumber of Adverse Events13 Adverse events
CGF166 Dose 60 μLNumber of Adverse Events8 Adverse events
TotalNumber of Adverse Events46 Adverse events
Primary

Number of Participants With Adverse Events

AE tables are below in the Adverse Events section of this report.

Time frame: week 52

Population: The Safety Analysis Set was comprised of all subjects that received study drug and with no protocol deviations having relevant impact on safety.

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
CGF166 Dose 20 μLNumber of Participants With Adverse Events3 Participants
CGF166 Dose 30 μLEdit Single Dose Volume #2Number of Participants With Adverse Events6 Participants
CGF166 Dose 40 μLNumber of Participants With Adverse Events4 Participants
CGF166 Dose 60 μLNumber of Participants With Adverse Events3 Participants
TotalNumber of Participants With Adverse Events16 Participants
Primary

Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit

Summary of change from baseline in Non-treated ear's pure tone audiometry air conduction threshold by frequency for last study visit is presented in table below.

Time frame: Week 52

Population: Pharmacodynamics (PD) analysis set was comprised of all subjects with any available PD data, who received any study drug and experienced no protocol deviations with relevant impact on PD data.

ArmMeasureGroupValue (MEAN)Dispersion
CGF166 Dose 20 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz-2.5 decibelsStandard Deviation 6.61
CGF166 Dose 20 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz0.8 decibelsStandard Deviation 2.89
CGF166 Dose 20 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz0 decibelsStandard Deviation 8.66
CGF166 Dose 20 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz0 decibelsStandard Deviation 5
CGF166 Dose 20 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz-0.8 decibelsStandard Deviation 1.44
CGF166 Dose 20 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz0.8 decibelsStandard Deviation 1.44
CGF166 Dose 20 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz-2.5 decibelsStandard Deviation 6.61
CGF166 Dose 20 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz1.7 decibelsStandard Deviation 2.89
CGF166 Dose 20 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz-3.3 decibelsStandard Deviation 5.77
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz-0.6 decibelsStandard Deviation 3.56
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz0.2 decibelsStandard Deviation 4.94
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz1.0 decibelsStandard Deviation 3.76
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz0.2 decibelsStandard Deviation 7.27
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz1.7 decibelsStandard Deviation 4.81
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz-4.2 decibelsStandard Deviation 10.78
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz2.3 decibelsStandard Deviation 5.48
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz6.0 decibelsStandard Deviation 18.87
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz1.7 decibelsStandard Deviation 4.92
CGF166 Dose 40 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz0.6 decibelsStandard Deviation 1.25
CGF166 Dose 40 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz-3.1 decibelsStandard Deviation 2.39
CGF166 Dose 40 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz-2.5 decibelsStandard Deviation 3.54
CGF166 Dose 40 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz-2.5 decibelsStandard Deviation 3.54
CGF166 Dose 40 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz0 decibelsStandard Deviation 2.04
CGF166 Dose 40 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz-0.6 decibelsStandard Deviation 2.39
CGF166 Dose 40 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz1.3 decibelsStandard Deviation 2.5
CGF166 Dose 40 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz-8.1 decibelsStandard Deviation 11.79
CGF166 Dose 40 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz-8.8 decibelsStandard Deviation 17.5
CGF166 Dose 60 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz-1.7 decibelsStandard Deviation 1.44
CGF166 Dose 60 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz-7.5 decibelsStandard Deviation 2.5
CGF166 Dose 60 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz-1.7 decibelsStandard Deviation 2.5
CGF166 Dose 60 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz-0.8 decibelsStandard Deviation 6.29
CGF166 Dose 60 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz0.8 decibelsStandard Deviation 2.89
CGF166 Dose 60 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz-0.8 decibelsStandard Deviation 6.29
CGF166 Dose 60 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz-1.7 decibelsStandard Deviation 5.77
CGF166 Dose 60 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz-1.7 decibelsStandard Deviation 3.82
CGF166 Dose 60 μLSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz-2.5 decibelsStandard Deviation 4.33
TotalSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz8.5 decibelsStandard Deviation 4.87
TotalSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz8.2 decibelsStandard Deviation 3.83
TotalSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz5.1 decibelsStandard Deviation 4.84
TotalSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz9.1 decibelsStandard Deviation 14.32
TotalSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz4.8 decibelsStandard Deviation 5.66
TotalSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz0.8 decibelsStandard Deviation 10.83
TotalSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz3.2 decibelsStandard Deviation 6.19
TotalSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz3.3 decibelsStandard Deviation 4.25
TotalSummary of Change From Baseline in Non-treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz7.7 decibelsStandard Deviation 5.45
Primary

Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit

Summary of change from baseline in pure tone audiometry air conduction threshold by frequency for last study visit is presented in table below.

Time frame: Week 52

Population: Pharmacodynamics (PD) analysis set was comprised of all subjects with any available PD data, who received any study drug and experienced no protocol deviations with relevant impact on PD data.

ArmMeasureGroupValue (MEAN)Dispersion
CGF166 Dose 20 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz1.7 decibelsStandard Deviation 2.89
CGF166 Dose 20 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz0.8 decibelsStandard Deviation 6.29
CGF166 Dose 20 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz-3.3 decibelsStandard Deviation 6.29
CGF166 Dose 20 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz2.5 decibelsStandard Deviation 2.5
CGF166 Dose 20 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz1.7 decibelsStandard Deviation 2.89
CGF166 Dose 20 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz0 decibelsStandard Deviation 5
CGF166 Dose 20 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz0.8 decibelsStandard Deviation 1.44
CGF166 Dose 20 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz-0.8 decibelsStandard Deviation 3.82
CGF166 Dose 20 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz-4.2 decibelsStandard Deviation 9.46
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz4.4 decibelsStandard Deviation 12.97
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz5.8 decibelsStandard Deviation 11.6
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz8.1 decibelsStandard Deviation 10.51
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz6.0 decibelsStandard Deviation 11.4
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz7.7 decibelsStandard Deviation 11
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz2.9 decibelsStandard Deviation 15.33
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz6.0 decibelsStandard Deviation 9.2
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz6.7 decibelsStandard Deviation 10.19
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz3.3 decibelsStandard Deviation 13.16
CGF166 Dose 40 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz11.9 decibelsStandard Deviation 11.06
CGF166 Dose 40 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz26.3 decibelsStandard Deviation 17.02
CGF166 Dose 40 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz26.3 decibelsStandard Deviation 26.65
CGF166 Dose 40 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz26.3 decibelsStandard Deviation 23.32
CGF166 Dose 40 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz16.9 decibelsStandard Deviation 8.98
CGF166 Dose 40 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz6.9 decibelsStandard Deviation 8.51
CGF166 Dose 40 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz5.0 decibelsStandard Deviation 4.08
CGF166 Dose 40 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz7.5 decibelsStandard Deviation 15
CGF166 Dose 40 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz-8.8 decibelsStandard Deviation 17.5
CGF166 Dose 60 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz5.8 decibelsStandard Deviation 1.44
CGF166 Dose 60 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz-4.2 decibelsStandard Deviation 3.82
CGF166 Dose 60 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz0.8 decibelsStandard Deviation 1.44
CGF166 Dose 60 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz-0.8 decibelsStandard Deviation 3.82
CGF166 Dose 60 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz0.8 decibelsStandard Deviation 1.44
CGF166 Dose 60 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz4.2 decibelsStandard Deviation 7.22
CGF166 Dose 60 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz1.7 decibelsStandard Deviation 6.29
CGF166 Dose 60 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz5.0 decibelsStandard Deviation 4.33
CGF166 Dose 60 μLSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz0.8 decibelsStandard Deviation 3.82
TotalSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit125 hz8.5 decibelsStandard Deviation 13.88
TotalSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit1,000 Hz8.2 decibelsStandard Deviation 9.89
TotalSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit3,000 Hz5.1 decibelsStandard Deviation 10.59
TotalSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit500 Hz9.1 decibelsStandard Deviation 14.91
TotalSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit2,000 Hz4.8 decibelsStandard Deviation 9.48
TotalSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit8,000 Hz0.8 decibelsStandard Deviation 13.94
TotalSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit6,000 Hz3.2 decibelsStandard Deviation 11.6
TotalSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit4,000 Hz3.3 decibelsStandard Deviation 9.83
TotalSummary of Change From Baseline in Treated Ear's Pure Tone Audiometry Air Conduction Threshold by Frequency for Last Study Visit250 Hz7.7 decibelsStandard Deviation 15.52
Primary

Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment Values

Summary of pure tone audiometry air conduction thresholds at frequency 0.125 KHz

Time frame: Days 29, 57, 85, 113, 141, 169, 358, 537, 600

Population: Pharmacodynamics (PD) analysis set was comprised of all subjects with any available PD data, who received any study drug and experienced no protocol deviations with relevant impact on PD data.

ArmMeasureGroupValue (MEAN)Dispersion
CGF166 Dose 20 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 5761.7 DECIBELSStandard Deviation 20.82
CGF166 Dose 20 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 14160.0 DECIBELSStandard Deviation 27.84
CGF166 Dose 20 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 2961.7 DECIBELSStandard Deviation 20.82
CGF166 Dose 20 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 11360.0 DECIBELSStandard Deviation 27.84
CGF166 Dose 20 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesBaseline63.3 DECIBELSStandard Deviation 18.93
CGF166 Dose 20 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 8561.7 DECIBELSStandard Deviation 25.66
CGF166 Dose 20 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 60060.0 DECIBELSStandard Deviation 27.84
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 5771.4 DECIBELSStandard Deviation 15.34
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 60077.5 DECIBELSStandard Deviation 15.68
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 16972.1 DECIBELSStandard Deviation 11.85
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 8566.3 DECIBELSStandard Deviation 14.36
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 14168.8 DECIBELSStandard Deviation 14.93
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 11373.6 DECIBELSStandard Deviation 14.33
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 2970.4 DECIBELSStandard Deviation 22.1
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesBaseline70.0 DECIBELSStandard Deviation 14.62
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 53782.5 DECIBELSStandard Deviation 10.61
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 35880.0 DECIBELSStandard Deviation 14.14
CGF166 Dose 40 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 14191.3 DECIBELSStandard Deviation 22.87
CGF166 Dose 40 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesBaseline70.0 DECIBELSStandard Deviation 20.41
CGF166 Dose 40 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 2985.0 DECIBELSStandard Deviation 10.8
CGF166 Dose 40 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 5786.3 DECIBELSStandard Deviation 8.54
CGF166 Dose 40 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 8588.8 DECIBELSStandard Deviation 24.96
CGF166 Dose 40 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 11392.5 DECIBELSStandard Deviation 23.63
CGF166 Dose 40 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 60093.8 DECIBELSStandard Deviation 9.46
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 11375.0 DECIBELSStandard Deviation 15
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 8575.0 DECIBELSStandard Deviation 15
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 14173.3 DECIBELSStandard Deviation 14.43
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 5773.3 DECIBELSStandard Deviation 15.28
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 16970.0 DECIBELSStandard Deviation 7.07
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 35872.5 DECIBELSStandard Deviation 10.61
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 2975.0 DECIBELSStandard Deviation 15
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 53775.0 DECIBELS
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesBaseline71.7 DECIBELSStandard Deviation 16.07
CGF166 Dose 60 μLSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 60082.5 DECIBELSStandard Deviation 17.68
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesBaseline69.3 DECIBELSStandard Deviation 15.38
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 8573.6 DECIBELSStandard Deviation 21.16
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 35877.5 DECIBELSStandard Deviation 12.55
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 5773.1 DECIBELSStandard Deviation 15.85
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 11375.5 DECIBELSStandard Deviation 19.55
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 14174.3 DECIBELSStandard Deviation 21.65
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 60078.7 DECIBELSStandard Deviation 18.77
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 53780.0 DECIBELSStandard Deviation 8.66
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 16971.7 DECIBELSStandard Deviation 10.61
TotalSummary of Pure Tone Audiometry in Treated Ear Compared to Pretreatment ValuesDay 2972.5 DECIBELSStandard Deviation 19.62
Primary

Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and Frequency

Summary of pure tone audiometry bone conduction thresholds by time and frequency 0.250 KHz

Time frame: Days 29, 57, 85, 113, 141, 169, 358,537, EoS

Population: Pharmacodynamics (PD) analysis set was comprised of all subjects with any available PD data, who received any study drug and experienced no protocol deviations with relevant impact on PD data.

ArmMeasureGroupValue (MEAN)Dispersion
CGF166 Dose 20 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyBaseline55.0 decibelsStandard Deviation 0
CGF166 Dose 20 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 11350.0 decibelsStandard Deviation 8.66
CGF166 Dose 20 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 2955.0 decibelsStandard Deviation 0
CGF166 Dose 20 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 14146.7 decibelsStandard Deviation 14.43
CGF166 Dose 20 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 5750.0 decibelsStandard Deviation 8.66
CGF166 Dose 20 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 1690 decibelsStandard Deviation 0
CGF166 Dose 20 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 8548.3 decibelsStandard Deviation 11.55
CGF166 Dose 20 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyEnd of Study48.3 decibelsStandard Deviation 11.55
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 53750 decibelsStandard Deviation 7.07
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 35845.0 decibelsStandard Deviation 8.16
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 8590.0 decibelsStandard Deviation 40.41
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 14151.3 decibelsStandard Deviation 7.5
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 5756.8 decibelsStandard Deviation 7.83
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 11357.7 decibelsStandard Deviation 23.17
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyEnd of Study61.5 decibelsStandard Deviation 22.37
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 16948.6 decibelsStandard Deviation 8.52
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 2973.8 decibelsStandard Deviation 31.49
CGF166 Dose 30 μLEdit Single Dose Volume #2Summary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyBaseline64.2 decibelsStandard Deviation 28.83
CGF166 Dose 40 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 14190.0 decibelsStandard Deviation 40.41
CGF166 Dose 40 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyBaseline87.5 decibelsStandard Deviation 43.5
CGF166 Dose 40 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 2963.8 decibelsStandard Deviation 42.11
CGF166 Dose 40 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 5790.0 decibelsStandard Deviation 40.41
CGF166 Dose 40 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 8590.0 decibelsStandard Deviation 40.41
CGF166 Dose 40 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 11386.3 decibelsStandard Deviation 45.16
CGF166 Dose 40 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyEnd of Study90.0 decibelsStandard Deviation 40.41
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 11353.3 decibelsStandard Deviation 2.89
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 8551.7 decibelsStandard Deviation 5.77
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 14151.7 decibelsStandard Deviation 5.77
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 5755.0 decibelsStandard Deviation 0
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 16950.0 decibelsStandard Deviation 7.07
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 35855.00 decibelsStandard Deviation 0
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 2955.0 decibelsStandard Deviation 0
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 53740 decibels
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyBaseline55.0 decibelsStandard Deviation 0
CGF166 Dose 60 μLSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyEnd of Study50.0 decibelsStandard Deviation 7.07
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyBaseline65.9 decibelsStandard Deviation 28.81
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 8572.9 decibelsStandard Deviation 34.68
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 35848.3 decibelsStandard Deviation 8.16
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 11361.4 decibelsStandard Deviation 27.26
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 14161.4 decibelsStandard Deviation 27.97
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 5761.9 decibelsStandard Deviation 21.99
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyEnd of Study64.2 decibelsStandard Deviation 27.5
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 53746.7 decibelsStandard Deviation 7.64
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 16948.9 decibelsStandard Deviation 7.82
TotalSummary Pure Tone Audiometry Bone Conduction Thresholds in Treated Ear by Time and FrequencyDay 2966.8 decibelsStandard Deviation 29.01
Secondary

Number of Participants With Change in Brainstem Auditory Evoked Responses (BAER) Compared to Pretreatment Values

BAERs was assessed with standard techniques for clinically significant threshold improvements compared to baseline levels.

Time frame: 24 months

Population: PD analysis set

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
CGF166 Dose 20 μLNumber of Participants With Change in Brainstem Auditory Evoked Responses (BAER) Compared to Pretreatment Values0 Participants
CGF166 Dose 30 μLEdit Single Dose Volume #2Number of Participants With Change in Brainstem Auditory Evoked Responses (BAER) Compared to Pretreatment Values0 Participants
CGF166 Dose 40 μLNumber of Participants With Change in Brainstem Auditory Evoked Responses (BAER) Compared to Pretreatment Values0 Participants
CGF166 Dose 60 μLNumber of Participants With Change in Brainstem Auditory Evoked Responses (BAER) Compared to Pretreatment Values0 Participants
TotalNumber of Participants With Change in Brainstem Auditory Evoked Responses (BAER) Compared to Pretreatment Values0 Participants
Secondary

Number of Participants With Changes in Auditory Functions (Speech Recognition) and Vestibular Functions Before and After IL Infusion of CGF166 Between the Study Ear and the Contralateral Ear

Clinically signficant speech recognition improvement (word and/or sentence) following treatment. The individual auditory assessments were speech audiometry, AzBio sentence test, consonant nucleus consonant test, word recognition, Hearing-in-Noise Test (HINT), Brainstem auditory evoked response evaluations (BAER), Distortion product otoacoustic emission testing (DPOE) and shoebox audiometry.

Time frame: 24 months

Population: PD analysis set

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
CGF166 Dose 20 μLNumber of Participants With Changes in Auditory Functions (Speech Recognition) and Vestibular Functions Before and After IL Infusion of CGF166 Between the Study Ear and the Contralateral Ear0 Participants
CGF166 Dose 30 μLEdit Single Dose Volume #2Number of Participants With Changes in Auditory Functions (Speech Recognition) and Vestibular Functions Before and After IL Infusion of CGF166 Between the Study Ear and the Contralateral Ear0 Participants
CGF166 Dose 40 μLNumber of Participants With Changes in Auditory Functions (Speech Recognition) and Vestibular Functions Before and After IL Infusion of CGF166 Between the Study Ear and the Contralateral Ear0 Participants
CGF166 Dose 60 μLNumber of Participants With Changes in Auditory Functions (Speech Recognition) and Vestibular Functions Before and After IL Infusion of CGF166 Between the Study Ear and the Contralateral Ear0 Participants
TotalNumber of Participants With Changes in Auditory Functions (Speech Recognition) and Vestibular Functions Before and After IL Infusion of CGF166 Between the Study Ear and the Contralateral Ear0 Participants
Secondary

Number of Participants With Response in Vestibular Function in Treated Ear Compared to Pretreatment Values

Response in vestibular assessments (Head impulse test (HIT), Vestibular evoked myogenic potential (VEMP), Subjective visual vertical (SVV)) to CGF166.

Time frame: 24 months

Population: PD Analysis Set

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
CGF166 Dose 20 μLNumber of Participants With Response in Vestibular Function in Treated Ear Compared to Pretreatment Values0 Participants
CGF166 Dose 30 μLEdit Single Dose Volume #2Number of Participants With Response in Vestibular Function in Treated Ear Compared to Pretreatment Values0 Participants
CGF166 Dose 40 μLNumber of Participants With Response in Vestibular Function in Treated Ear Compared to Pretreatment Values0 Participants
CGF166 Dose 60 μLNumber of Participants With Response in Vestibular Function in Treated Ear Compared to Pretreatment Values0 Participants
TotalNumber of Participants With Response in Vestibular Function in Treated Ear Compared to Pretreatment Values0 Participants

Source: ClinicalTrials.gov · Data processed: Feb 28, 2026