Skip to content

Comparison of Laryngeal Mask Airway Supreme and Endotracheal Tube In Patients Undergoing Gynecological Laparoscopy Surgery

Comparison of Laryngeal Mask Airway Supreme and Endotracheal Tube In Patients Undergoing Gynecological Laparoscopy Surgery

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02127632
Enrollment
100
Registered
2014-05-01
Start date
2012-04-30
Completion date
2013-05-31
Last updated
2017-12-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anaesthesia

Keywords

laryngeal mask Supreme, laparoscopic gynecologic surgery, Laryngeal mask during surgery

Brief summary

Endotracheal Tube (ETT) is still preferred for laparoscopic surgeries because of the fear of pulmonary aspiration and inadequate ventilation. Laryngeal mask Supreme (LM-S) is a single use device and the presence of a drain tube allows to separate the gastrointestinal and respiratory tracts. We planned to compare ventilation parameters and gastric distension scores of with LM-S vs ETT during laparoscopic gynecological surgery.

Detailed description

This prospective, randomized and double-blind study received permission from Dokuz Eylül University Medical Faculty Non-Interventional Research Ethics Committee and after obtaining patients' informed consent, 100 patients with American society of anesthesiologists (ASA) classification group I-II, between 18-65 years, undergoing elective laparoscopic gynecological surgery were included. Patients were divided into: Group 1=\>ETT (Endo tracheal group) (50 patients) Group 2=\>LM-S (Laryngeal mask Supreme) (50 patients) Patients and surgeons performing the operation were not aware of which airway device was used. The patients in the groups were determined by block randomized methods. Patients taken to the surgical room were given standard monitoring (non-invasive blood pressure measurements, electrocardiogram, and peripheral oxygen saturation measurements) before anesthesia induction. For preoperative sedation 0.02 mg/kg midazolam IV was administered. Patients were preoxygenated with 6 L/min oxygen for 3 minutes through a face mask. For anesthesia induction after 2 minutes of 0.2 µg/kg/min remifentanil and 6 mg/kg/hr propofol infusion, IV 1-2 mg/kg propofol , 0,5 mg/kg rocuronium bromide was administered. After induction patients were ventilated with 6 L/min 100% oxygen through a face mask. Airway devices were inserted by two researchers with more than 5 years experience. Anesthetic maintenance was provided by 50% O2/air mixture with 0.1-0.4 µg/kg/min remifentanil and 50-150 µg/kg/hr (3-9 mg/kg/hr) propofol IV infusion (24). Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based gel without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted. After LM-S placement the cuff was inflated with air so as to have a pressure below 60 water of centimeter (cmH20) (cuff pressure manometer, Rusch, Germany). Two minutes after LM-S placement, before insufflation, 10 minutes after insufflation and trendelenburg position, before desufflation and before LM-S removal, cuff pressure was measured repeatedly and recorded. At the same time intervals in the ETT group, ETT cuff pressure was measured. In the ETT group for women no. 7-7.5 tube was used. The ETT cuff was inflated until the leak sound ceased. It was measured with a manometer to remain between 20-30 water of centimeter (cmH20). Successful placement of LM-S or ETT was confirmed by square-shaped waves observed on the capnogram, easy ventilation of the respiration balloon and visible chest movements. After successful placement of the airway device, it was covered to prevent observation of which device was used. The length of time for successful placement (duration from mouth opening to first successful ventilation), number of tries, and ease of placement were recorded. Ease of placement was evaluated by the anesthetist in charge of the airway as easy, hard or unsuccessful (alternative airway management). In a situation where airway provision was unsuccessful after 3 tries, patients without placement of LM-S or who could not be intubated were switched to the other group and airway management was provided. For oropharyngeal leak test after the expiratory valve was closed air was shut off, O2 was reduced to 3 L/min and the first pressure value when a leak sound was heard was recorded as the oropharyngeal leak pressure. To prevent exposure of the lungs to barotrauma, when the peak inspiratory pressure reached 40 cmH2O the expiratory valve was opened and the test was concluded. This test was repeated before peritoneal insufflation, 10 minutes later and immediately before desufflation and was completed by a researcher blind to the type of airway device inserted. Positive pressure respiration was begun by using a ring system, 2-4 L/min fresh gas flow and 0.5 fraction of inspired oxygen (FiO2) volume controlled 6-8 ml/kg tidal volume and 10 respirations/min frequency. PEEP was not administered and I:E ratio was adjusted to 1:2. ETCO2 was held between 35-45 mmHg, if necessary first respiration frequency was increased then tidal volume was increased. Permission was given for CO2 insufflation for the laparoscopic intervention with peritoneal interior pressure of 15 mmHg. Two minutes after LM-S or ETT placement, before insufflation, 10 minutes after insufflation and trendelenburg position, immediately before peritoneal desufflation and before airway device removal, ventilation parameters were evaluated. Respiratory measurements to be recorded: Tidal volume (TV), respiration number (RN), peripheral oxygen saturation (SPO2), end-tidal carbon dioxide pressure (PETCO2), peak airway pressure (P peak), mean airway pressure (P mean) and expiration volume per minute (VE). Hemodynamic measurements to be recorded: (simultaneous to the measurements above and additionally before induction) Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) and heart rate (HR). Evaluation related to gastric tube: Immediately after airway device placement using either the LM-S drainage tube or in intubated patients using a 14 Ch orogastric probe within the airway, the stomach was reached and the gastric contents were aspirated. Ease of placement and amount of fluids aspirated were recorded. Ease of placement was classified by the person who inserted the orogastric probe as very easy, easy, difficult and very difficult. Immediately after the intra-abdominal laparoscopic intervention and immediately before peritoneal insufflation was ended, gastric distension was evaluated by a surgeon blind to the airway device used between 0-10 (0=empty stomach, 10=distension obstructing the surgical field) and the difference between the scores at the start and end of the operation was recorded . When the patient cooperated LM-S or ETT was removed and total anesthesia duration and peritoneal insufflation duration was recorded. Possible complications that could develop during airway device removal (coughing, vomiting, laryngeal stridor, laryngeal spasm or requirement for airway intervention) were recorded. After LM-S removal the presence of blood was evaluated as 1. no blood 2. trace amounts of blood 3. clear amount of blood Revived patients were taken to the recovery unit and a blind researcher evaluated the patients' throat pain, hoarseness and presence of difficulty swallowing in the 1st and 24th hours. To evaluate throat pain the visual analogue scale was used.

Interventions

DEVICEEndotracheal Tube

ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482

Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based K-YTM gel (Johnson & Johnson Ltd. Maidenhead, UK) without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted. Other Names: LM-S (The Laryngeal Mask Company Limited, Singapore) serial number: 175030 lot: hmabw7

Sponsors

Dokuz Eylul University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SCREENING
Masking
DOUBLE (Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

* ASA classification group I-II * Between 18-65 years * Undergoing elective laparoscopic gynecological surgery

Exclusion criteria

* Individuals with any neck and upper respiratory pathology * Individuals at risk of gastric content regurgitation/aspiration (previous upper gastrointestinal surgery, known hiatus hernia, gastroesophageal reflux, history of peptic ulcer, full stomach, pregnancy) * Individuals with low pulmonary compliance or high airway resistance (chronic lung diseases) * Obese patients (BMI \>35) * Individuals with sore throat, dysphagia and dysphonia * Individuals with possibility or history of difficult airway * Operation time planned for more than 4 hours

Design outcomes

Primary

MeasureTime frameDescription
Mean Airway PressuresAt first and last 10 minutes of pneumoperitoneumThe measure is the mean airway pressure (cmH2O): T1= 2 minutes after airway device insertion T2= 10 minutes after insufflation T3= Before desufflation T4= Before removal of airway device

Secondary

MeasureTime frameDescription
Evaluation of Gastric DistentionBaselineTo provide the adequate gastric distention of either the LM-Supreme or the tracheal tube, as assigned. Gastric distension was evaluated by a surgeon blind to the airway device used between 0-10 (0=empty stomach, 10=distension obstructing the surgical field)
Throat Pain According to Visual Analogue Scalepostoperative 1st and 24th hoursPatients were asked about the presence of sore throat - defined as the presence of constant pain in the throat, 1 hr and 24 hr after the end of surgery according to Visual Analogue Scale. (range min. 0, max.10; \>4 analgesia planned)

Countries

Turkey (Türkiye)

Participant flow

Participants by arm

ArmCount
Group ETT (Endo Tracheal Tube)
Group ETT (Endotracheal tube Group). In the ETT group for women no. 7-7.5 tube will use. ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482 Laryngeal Mask Airway-Supreme: Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based K-YTM gel (Johnson & Johnson Ltd. Maidenhead, UK) without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted. Other Names: LM-S (The Laryngeal Mask Company Limited, Singapore) serial number: 175030 lot: hmabw7
50
Group LM-S(Laryngeal Mask Supreme Group)
Experimental: Group LM-S Group LM-S (Laryngeal mask supreme Group) For \<50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) will insert. Endotracheal Tube: ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
50
Total100

Baseline characteristics

CharacteristicGroup ETT (Endo Tracheal Tube)Group LM-S(Laryngeal Mask Supreme Group)Total
Age, Continuous39.36 years
STANDARD_DEVIATION 11.52
38.86 years
STANDARD_DEVIATION 11.48
39.11 years
STANDARD_DEVIATION 11.45
Region of Enrollment
Turkey
50 participants50 participants100 participants
Sex: Female, Male
Female
50 Participants50 Participants100 Participants
Sex: Female, Male
Male
0 Participants0 Participants0 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 500 / 50
other
Total, other adverse events
0 / 500 / 50
serious
Total, serious adverse events
0 / 500 / 50

Outcome results

Primary

Mean Airway Pressures

The measure is the mean airway pressure (cmH2O): T1= 2 minutes after airway device insertion T2= 10 minutes after insufflation T3= Before desufflation T4= Before removal of airway device

Time frame: At first and last 10 minutes of pneumoperitoneum

ArmMeasureGroupValue (MEAN)
Group ETT (Endo Tracheal Tube)Mean Airway PressuresT17 cmH20
Group ETT (Endo Tracheal Tube)Mean Airway PressuresT28 cmH20
Group ETT (Endo Tracheal Tube)Mean Airway PressuresT38 cmH20
Group ETT (Endo Tracheal Tube)Mean Airway PressuresT47 cmH20
Group LM-S(Laryngeal Mask Supreme Group)Mean Airway PressuresT47 cmH20
Group LM-S(Laryngeal Mask Supreme Group)Mean Airway PressuresT16 cmH20
Group LM-S(Laryngeal Mask Supreme Group)Mean Airway PressuresT38 cmH20
Group LM-S(Laryngeal Mask Supreme Group)Mean Airway PressuresT28 cmH20
Secondary

Evaluation of Gastric Distention

To provide the adequate gastric distention of either the LM-Supreme or the tracheal tube, as assigned. Gastric distension was evaluated by a surgeon blind to the airway device used between 0-10 (0=empty stomach, 10=distension obstructing the surgical field)

Time frame: Baseline

ArmMeasureValue (MEAN)Dispersion
Group ETT (Endo Tracheal Tube)Evaluation of Gastric Distention3.24 units on a scaleStandard Deviation 1.99
Group LM-S(Laryngeal Mask Supreme Group)Evaluation of Gastric Distention2.02 units on a scaleStandard Deviation 1.07
Secondary

Throat Pain According to Visual Analogue Scale

Patients were asked about the presence of sore throat - defined as the presence of constant pain in the throat, 1 hr and 24 hr after the end of surgery according to Visual Analogue Scale. (range min. 0, max.10; \>4 analgesia planned)

Time frame: postoperative 1st and 24th hours

ArmMeasureGroupValue (MEAN)Dispersion
Group ETT (Endo Tracheal Tube)Throat Pain According to Visual Analogue Scalepostoperative 24th hours0 pointStandard Deviation 0
Group ETT (Endo Tracheal Tube)Throat Pain According to Visual Analogue Scalepostoperative 1st hour2.04 pointStandard Deviation 1.61
Group LM-S(Laryngeal Mask Supreme Group)Throat Pain According to Visual Analogue Scalepostoperative 1st hour0.32 pointStandard Deviation 0.76
Group LM-S(Laryngeal Mask Supreme Group)Throat Pain According to Visual Analogue Scalepostoperative 24th hours0 pointStandard Deviation 0

Source: ClinicalTrials.gov · Data processed: Mar 3, 2026