Characterization of Changes in Ventricular Mechanics in Response to Lexiscan Stress Using Tagged Cine Cardiac Magnetic Resonance Imaging

Characterization of Changes in Ventricular Mechanics in Response to Lexiscan Stress Using Tagged Cine Cardiac Magnetic Resonance Imaging

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02115308
Enrollment
40
Registered
2014-04-16
Start date
2014-09-03
Completion date
2018-03-23
Last updated
2018-09-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

The purpose of this study is to measure the changes in cardiac function during a Lexiscan pharmacologic stress test using cardiac magnetic resonance imaging test.

Interventions

DRUGRegadenoson

Regadenoson injection is a pharmacologic stress agent indicated for radionuclide myocardial perfusion imaging.

Sponsors

Saint Luke's Health System
CollaboratorOTHER
Saint Luke's Cardiovascular Consultants
CollaboratorOTHER
Timothy M. Bateman
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
19 Years to 90 Years
Healthy volunteers
Yes

Inclusion criteria

* Myocardial rest/regadenoson stress perfusion PET study within 60 days * Normal rest LVEF (greater than or equal to 50%) * No change in symptoms or treatment between the PET and the MRI study * Willing to consent to the study * Male or female who is either post-menopausal, surgically sterile, or if has a childbearing potential, a negative pregnancy test within 2 days prior to the MRI study.

Exclusion criteria

* Renal dysfunction (estimated glomerular filtration rate \< 60 mL/min/1.73m2) within 6 months * Metallic implants, pacemaker, blood vessel clip (contra-indicated for MRI) * Patient size exceeds MRI bore/table limits: (Max body diameter \> 60 cm, weight \> 136 kg) * History of gadolinium contrast allergy or intolerance * Second or third degree AV block * Sinus node dysfunction * Acute myocardial infarction (past 3 months) * Actively wheezing or with acute asthma or bronchospastic attacks requiring changes in therapy within the past 30 days * Patients that have experienced a previous hypersensitivity reaction thought to be related to regadenoson

Design outcomes

Primary

MeasureTime frameDescription
RADIAL STRAINDay 1A measurement of the relative displacement between myocardial points between end-diastole and end-systole along a common ray extending from the center of the left ventricular (LV) cavity (analogous to myocardial thickening). A normal radial strain is indicated by a positive decimal value and can be understood as the percentage change in wall thickness of a myocardial segment. A POSITIVE change in radial strain indicates an increase in wall thickening. Because strain is a measurement in change in length (distance) divided by an original length (distance) it is considered unitless.
CIRCUMFERENTIAL STRAINDay 1A measurement of the relative displacement of myocardial points directed along the circumference of the ventricular wall at a given radial distance from the left ventricular (LV) cavity center (e.g. midline). A normal circumferential strain is indicated by a negative decimal value and can be understood as the percentage shortening along the ventricular wall with a greater negative value indicating greater ventricular shortening along the circumference. A positive change in strain would therefore be interpreted as a decrease in circumferential shortening. Because strain is a measurement in change in length (distance) divided by an original length (distance) it is considered unitless.

Secondary

MeasureTime frameDescription
Late Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainDay 1For each subject, the 16-segments were visually assessed along the short-axis plane for the presence of LGE. These images were collected post regadenoson stress recovery using an inversion-recovery prepared, fast gradient echo sequence and a delay of at least 8 minutes after administration of a single dose of gadobenate dimeglumine. The presence of LGE within a segment is a separate classification of segment type. The segment classifications in the other outcomes are determined from the prior positron-emission-tomography (PET) examination where the LGE determination is based solely on cardiac magnetic resonance (CMR) imaging collected data. The measurement was performed to determine if the presence of LGE within a particular segment affect the resulting strain?
Adverse EventsDay 1Adverse events were monitored and recorded on a specific Adverse Event (AE) log.
Late Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainDay 1The Effects of the presence of LGE on CIRCUMFERENTIAL myocardial Strain

Countries

United States

Participant flow

Recruitment details

All subjects were recruited from two groups: a population with coronary artery disease (CAD) of those with low-likelihood-CAD (Control). The myocardial segment perfusion and wall motion scores from the prior clinical positron-emission-tomography (PET) were used to classify segments as one of the following: CONTROL, CAD\_REMOTE, CAD\_REVERSIBLE.

Pre-assignment details

Cardiac Magnetic Resonance (CMR) imaging was performed in the same order for all subjects with rest imaging preceding regadenoson stress imaging. The same prescription for tagged CMR slice locations (basal, mid, and apical) were used at both rest and stress.

Participants by arm

ArmCount
CONTROL
Myocardial strain imaging was performed for all subjects in a similar order. Rest-tag imaging was performed first, then Stress-tag imaging was performed at maximal heart rate following administration of the regadenoson dose. Strain values were then calculated for each of 16-segments for each subject. Segments are classified based on myocardial perfusion imaging scores. A control subject is an individual from a low-likelihood CAD population with a prior clinically indicated PET with perfusion and wall motion scores (rest-to-stress).
13
Coronary Artery Disease
Myocardial strain imaging was performed for all subjects in a similar order. Rest-tag imaging was performed first, then Stress-tag imaging was performed at maximal heart rate following administration of the regadenoson dose. Strain values were then calculated for each of 16-segments for each subject. Segments are classified based on myocardial perfusion imaging scores. A Coronary artery disease subject is an individual from a CAD population with a prior clinically indicated PET with perfusion and wall motion scores (rest-to-stress).
23
Total36

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudySafety Screening22

Baseline characteristics

CharacteristicCONTROLCoronary Artery DiseaseTotal
Age, Continuous55 years
STANDARD_DEVIATION 10
72 years
STANDARD_DEVIATION 9
66 years
STANDARD_DEVIATION 12
BMI32 kg/m^2
STANDARD_DEVIATION 6
31 kg/m^2
STANDARD_DEVIATION 6
31 kg/m^2
STANDARD_DEVIATION 6
Race and Ethnicity Not Collected0 Participants
Sex: Female, Male
Female
9 Participants7 Participants16 Participants
Sex: Female, Male
Male
4 Participants16 Participants20 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 36
other
Total, other adverse events
29 / 36
serious
Total, serious adverse events
0 / 36

Outcome results

Primary

CIRCUMFERENTIAL STRAIN

A measurement of the relative displacement of myocardial points directed along the circumference of the ventricular wall at a given radial distance from the left ventricular (LV) cavity center (e.g. midline). A normal circumferential strain is indicated by a negative decimal value and can be understood as the percentage shortening along the ventricular wall with a greater negative value indicating greater ventricular shortening along the circumference. A positive change in strain would therefore be interpreted as a decrease in circumferential shortening. Because strain is a measurement in change in length (distance) divided by an original length (distance) it is considered unitless.

Time frame: Day 1

Population: Myocardial segments from the population groups according to the AHA 16-segment model and classified according to PET perfusion and wall motion scores.

ArmMeasureGroupValue (MEAN)Dispersion
CONTROLCIRCUMFERENTIAL STRAINREGADENSOSON STRESS-0.169 strain (unitless)Standard Deviation 0.059
CONTROLCIRCUMFERENTIAL STRAINREST-0.181 strain (unitless)Standard Deviation 0.056
CONTROLCIRCUMFERENTIAL STRAINREST-to-STRESS CHANGE0.012 strain (unitless)Standard Deviation 0.065
CAD_REMOTECIRCUMFERENTIAL STRAINREGADENSOSON STRESS-0.150 strain (unitless)Standard Deviation 0.053
CAD_REMOTECIRCUMFERENTIAL STRAINREST-0.140 strain (unitless)Standard Deviation 0.057
CAD_REMOTECIRCUMFERENTIAL STRAINREST-to-STRESS CHANGE-0.013 strain (unitless)Standard Deviation 0.051
CAD_REVERSIBLECIRCUMFERENTIAL STRAINREST-0.121 strain (unitless)Standard Deviation 0.054
CAD_REVERSIBLECIRCUMFERENTIAL STRAINREST-to-STRESS CHANGE-0.006 strain (unitless)Standard Deviation 0.051
CAD_REVERSIBLECIRCUMFERENTIAL STRAINREGADENSOSON STRESS-0.126 strain (unitless)Standard Deviation 0.066
Comparison: Rest VS Regadenoson Stressp-value: 0.011paired, t-test
Comparison: Rest VS Regadenoson Stressp-value: 0.003paired t-test
Comparison: Rest VS Regadenoson Stressp-value: 0.39paired, t-test
Comparison: RESTp-value: <0t-test, 2 sided
Comparison: RESTp-value: <0t-test, 2 sided
Comparison: RESTp-value: 0.022t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.001t-test, 2 sided
Comparison: Regadenoson STRESSp-value: <0t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.006t-test, 2 sided
Comparison: REST-TO-STRESS Changep-value: <0t-test, 2 sided
Comparison: REST-TO-STRESS Changesp-value: 0.058t-test, 2 sided
Comparison: REST-TO-STRESS Changep-value: 0.31t-test, 2 sided
Primary

RADIAL STRAIN

A measurement of the relative displacement between myocardial points between end-diastole and end-systole along a common ray extending from the center of the left ventricular (LV) cavity (analogous to myocardial thickening). A normal radial strain is indicated by a positive decimal value and can be understood as the percentage change in wall thickness of a myocardial segment. A POSITIVE change in radial strain indicates an increase in wall thickening. Because strain is a measurement in change in length (distance) divided by an original length (distance) it is considered unitless.

Time frame: Day 1

Population: Myocardial segments classified according to subject groups and myocardial perfusion and wall motion scores on prior positron-emission-tomography (PET).

ArmMeasureGroupValue (MEAN)Dispersion
CONTROLRADIAL STRAINREGADENOSON STRESS0.190 unitless (strain)Standard Deviation 0.113
CONTROLRADIAL STRAINREST0.158 unitless (strain)Standard Deviation 0.1
CONTROLRADIAL STRAINREST-to-STRESS CHANGE0.033 unitless (strain)Standard Deviation 0.137
CAD_REMOTERADIAL STRAINREGADENOSON STRESS0.167 unitless (strain)Standard Deviation 0.104
CAD_REMOTERADIAL STRAINREST0.149 unitless (strain)Standard Deviation 0.098
CAD_REMOTERADIAL STRAINREST-to-STRESS CHANGE0.022 unitless (strain)Standard Deviation 0.107
CAD_REVERSIBLERADIAL STRAINREST0.150 unitless (strain)Standard Deviation 0.094
CAD_REVERSIBLERADIAL STRAINREST-to-STRESS CHANGE-0.009 unitless (strain)Standard Deviation 0.099
CAD_REVERSIBLERADIAL STRAINREGADENOSON STRESS0.141 unitless (strain)Standard Deviation 0.085
Comparison: REST-TO-REGADENOSON STRESSp-value: 0.001paired, t-test
Comparison: REST-TO-REGADENOSON STRESSp-value: 0.017paired, t-test
Comparison: REST-TO-REGADENOSON STRESSp-value: 0.495paired, t-test
Comparison: RESTp-value: 0.365t-test, 2 sided
Comparison: RESTp-value: 0.602t-test, 2 sided
Comparison: RESTp-value: 0.915t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.033t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.002t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.087t-test, 2 sided
Comparison: REST-TO-STRESS CHANGEp-value: 0.399t-test, 2 sided
Comparison: REST-TO-STRESS Changep-value: 0.03t-test, 2 sided
Comparison: REST-TO-STRESS Changep-value: 0.048t-test, 2 sided
Secondary

Adverse Events

Adverse events were monitored and recorded on a specific Adverse Event (AE) log.

Time frame: Day 1

Population: Count of Adverse Events not clinically expect and reportable to IRB.

ArmMeasureCategoryValue (COUNT_OF_PARTICIPANTS)
CONTROLAdverse EventsNo Adverse Events7 Participants
CONTROLAdverse EventsAdverse Events29 Participants
CONTROLAdverse EventsSerious Adverse Events0 Participants
Secondary

Late Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial Strain

The Effects of the presence of LGE on CIRCUMFERENTIAL myocardial Strain

Time frame: Day 1

Population: LGE as determined by CMR imaging using the AHA 16 segment model.

ArmMeasureGroupValue (MEAN)Dispersion
CONTROLLate Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainREST-to-STRESS0.012 strain (unitless)Standard Deviation 0.066
CONTROLLate Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainREGADENOSON STRESS-0.169 strain (unitless)Standard Deviation 0.059
CONTROLLate Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainREST-0.181 strain (unitless)Standard Deviation 0.057
CAD_REMOTELate Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainREST-to-STRESS-0.011 strain (unitless)Standard Deviation 0.046
CAD_REMOTELate Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainREST-0.139 strain (unitless)Standard Deviation 0.052
CAD_REMOTELate Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainREGADENOSON STRESS-0.150 strain (unitless)Standard Deviation 0.052
CAD_REVERSIBLELate Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainREGADENOSON STRESS-0.111 strain (unitless)Standard Deviation 0.051
CAD_REVERSIBLELate Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainREST-0.101 strain (unitless)Standard Deviation 0.063
CAD_REVERSIBLELate Gadolinium Enhancement and CIRCUMFERENTIAL Myocardial StrainREST-to-STRESS-0.010 strain (unitless)Standard Deviation 0.051
Comparison: REST vs STRESSp-value: 0.008paired, t-test
Comparison: REST vs STRESSp-value: 0.006paired, t-test
Comparison: REST vs STRESSp-value: 0.428paired, t-test
Comparison: RESTp-value: <0t-test, 2 sided
Comparison: RESTp-value: <0t-test, 2 sided
Comparison: RESTp-value: 0.006t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.002t-test, 2 sided
Comparison: Regadenoson STRESSp-value: <0t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.004t-test, 2 sided
Comparison: REST-to-STRESS Changep-value: <0t-test, 2 sided
Comparison: REST-to-STRESS Changep-value: 0.172t-test, 2 sided
Comparison: REST-to-STRESS Changep-value: 0.957t-test, 2 sided
Secondary

Late Gadolinium Enhancement (LGE) and RADIAL Myocardial Strain

For each subject, the 16-segments were visually assessed along the short-axis plane for the presence of LGE. These images were collected post regadenoson stress recovery using an inversion-recovery prepared, fast gradient echo sequence and a delay of at least 8 minutes after administration of a single dose of gadobenate dimeglumine. The presence of LGE within a segment is a separate classification of segment type. The segment classifications in the other outcomes are determined from the prior positron-emission-tomography (PET) examination where the LGE determination is based solely on cardiac magnetic resonance (CMR) imaging collected data. The measurement was performed to determine if the presence of LGE within a particular segment affect the resulting strain?

Time frame: Day 1

Population: LGE imaging by CMR was acquired only in subjects meeting GFR restrictions.

ArmMeasureGroupValue (MEAN)Dispersion
CONTROLLate Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainREGADENOSON STRESS0.190 strain (unitless)Standard Deviation 0.113
CONTROLLate Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainREST0.157 strain (unitless)Standard Deviation 0.1
CONTROLLate Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainREST-to_STRESS0.032 strain (unitless)Standard Deviation 0.136
CAD_REMOTELate Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainREGADENOSON STRESS0.185 strain (unitless)Standard Deviation 0.107
CAD_REMOTELate Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainREST0.155 strain (unitless)Standard Deviation 0.097
CAD_REMOTELate Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainREST-to_STRESS0.031 strain (unitless)Standard Deviation 0.116
CAD_REVERSIBLELate Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainREST0.140 strain (unitless)Standard Deviation 0.074
CAD_REVERSIBLELate Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainREST-to_STRESS-0.008 strain (unitless)Standard Deviation 0.089
CAD_REVERSIBLELate Gadolinium Enhancement (LGE) and RADIAL Myocardial StrainREGADENOSON STRESS0.132 strain (unitless)Standard Deviation 0.091
Comparison: REST vs STRESSp-value: 0.001paired, t-test
Comparison: REST vs STRESSp-value: 0.002paired, t-test
Comparison: REST vs STRESSp-value: 0.721paired, t-test
Comparison: RESTp-value: 0.797t-test, 2 sided
Comparison: RESTp-value: 0.474t-test, 2 sided
p-value: 0.537t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.717t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.041t-test, 2 sided
Comparison: Regadenoson STRESSp-value: 0.05t-test, 2 sided
Comparison: REST-to-STRESS Changep-value: 0.908t-test, 2 sided
p-value: 0.233t-test, 2 sided
Comparison: REST-to-STRESS Changep-value: 0.187t-test, 2 sided