Ultrasound Assisted Puncture of AV Fistulas in Chronic Hemodialysis Patients

Ultrasound Assisted Puncture of AV Fistulas in Chronic Hemodialysis Patients After a Short Learning Program in Bed-side Ultrasound for Hemodialysis Nurses by an Index Nurse - an Outcome Study

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02085486
Enrollment
0
Registered
2014-03-12
Start date
2017-08-31
Completion date
2018-05-31
Last updated
2023-01-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dialysis, Fistula

Keywords

dialysis, av shunt, cannulation, ultrasound, outcome

Brief summary

The puncture of the vascular access in hemodialysis patients remains challenging even in the hands of experienced dialysis nurses. Unsuccessful punctures are associated with resource wastage, traumatism of the AV shunts, shortening of the effective dialysis time and poor patient satisfaction. The use of ultrasound by emergency department nurses and technicians without prior ultrasound experience in patients with difficult intravenous access showed in several studies to be very efficient. The investigators expect to achieve similar results in cannulation of AV shunts by the dialysis nurse staff after a short learning program. To show this, the investigators aim to conduct a trail where standard cannulation technique (inspection, palpation) will be compared with the ultrasound-assisted method in terms of efficacy, safety and patient satisfaction.

Detailed description

Background The vascular access plays a central role in patients with end-stage renal disease undergoing chronic hemodialysis. It is well documented from various previous studies that the confection of the dialysis access and subsequent complications represent a major cause of morbidity, hospitalization and additional costs in chronic dialysis patients. In European countries most patients undergoing chronic hemodialysis use an arterio-venous fistula as permanent vascular access. Because of the anatomical differences of each individual and the accompanying chronic diseases affecting patients' vessels, cannulation of arterio-venous fistulas can be very challenging for the nursing personal and puncture failures necessitating repeated attempts are not so rare. The latter are often time-consuming and result in a loss of effective dialysis' time and reduced proceeded total blood volume, are associated with a higher rate of local complications due to repeated traumatisms of the vascular wall and can lead to severe pain with reduced patient satisfaction. In the investigators' dialysis unit, when a dialysis nurse is not able to puncture a fistula she refers to an experienced nurse who tries to cannulate the fistula after thorough visual and palpatory evaluation. In case of another failure, the nursing team refers to the dialysis physician, who performs a short diagnostic bed-side ultrasound of the vascular access to rule out the presence of thrombosis or large hematoma. Using ultrasound-guidance provided by the physician or after being informed about the localization and depth of the ideal puncture site, the dialysis nurse tries then to puncture the fistula again. This often leads to a greater loss of time with reduced effective dialysis dose, increased need for human resources and low patient satisfaction. The use of ultrasound by emergency department nurses and technicians without prior ultrasound experience in patients with difficult intravenous access showed in several studies to be very efficient. The method was safe, the procedure rapid, the patients more satisfied, the success rate as high as this from ultrasound trained emergency physicians and the need for physician intervention reduced. The achievement of similar results in AV fistula cannulation in hemodialysis patients would be very suitable. The use of ultrasound in patients with recognized difficult fistulas by dialysis nurses after a short ultrasound learning program provided by an index nurse will enable to achieve a higher rate of satisfactory double-needle punctures, usual blood flow rates and full dialysis length with less time loss and increased patient satisfaction. With this study prospective, single-centre, randomized, controlled study the investigators aim to show that the use of ultrasound by dialysis nurses in patients with difficult fistulas makes the punction of the fistulas easier than when assessing the fistula visually and manually. Objective The use of ultrasound in patients with recognized difficult fistulas by dialysis nurses after a short ultrasound learning program provided by an index nurse will enable to achieve a higher rate of satisfactory double-needle punctures, usual blood flow rates and full dialysis length with less time loss and increased patient satisfaction. With a prospective, controlled trail the investigators want to demonstrate this hypothesis. Methods A portable ultrasound device will be used by the nursing staff after a short learning program. Precise location of AV shunt segments and depth will be assessed in the case of a difficult shunt. This procedure will be compared with the standard inspection and palpation method.

Interventions

DEVICEUltrasound-assisted puncture

Portable ultrasound device

OTHERStandard

Standard inspection, palpation.

Sponsors

Insel Gruppe AG, University Hospital Bern
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Forearm or upper arm AV-shunt (native, mixed, graft) * Patients with recognized difficult vascular access at any time (potentially each patient) * Written informed consent

Exclusion criteria

* Recent AV-shunt surgery (\< 48 h) * Presence of large bandages or severe skin lesions in the area of interest * Inability to understand the aim of the study and to give a written informed consent * Single needle

Design outcomes

Primary

MeasureTime frameDescription
Rate of successful cannulations of an AV-fistulaImmediately after the cannulation, expected to be after 10 minutes on averageSatisfactory puncture of the fistula defined as the ability to achieve a full length dialysis (max. 10% reduction of the usual dialysis time), double-needle, and the usual blood flow rate (max. 15% reduction of the usual blood flow)

Secondary

MeasureTime frameDescription
Effective dialysis timeDirectly after the treatment, expected to be after 3 to 4.5 hoursMeasured in minutes
Processed volumeDirectly after the treatment, expected to be after 3 to 4.5 hours
Number of patients with late complicationsAt the following dialysis session, expected to be after 2-3 days
Patient satisfactionImmediately after the canulation, expected to be after 10 minutes on average, and at the following dialysis session, expected to be after 2-3 daysMeasured by questionnaire