Skip to content

Non-Invasive Evaluation of Transplant Kidney Using OCT

Non-Invasive Evaluation of Transplant Kidney Using OCT

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02084966
Enrollment
169
Registered
2014-03-12
Start date
2014-04-30
Completion date
2018-12-31
Last updated
2019-03-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic Kidney Disease

Keywords

Kidney, Transplantation, Imaging, Renal function, Optical Coherence Tomography

Brief summary

Optical coherence tomography (OCT) is a rapidly emerging imaging modality that can function as a type of optical biopsy, providing non-invasive cross-sectional images of tissue architectural morphology in situ and in real-time. This proposal will demonstrate that OCT has the ability to provide novel and valuable histopathological information regarding donor kidneys that can be used to predict post-transplant renal function. These investigations will result in a major breakthrough in increasing the number of healthy kidneys available for transplantation by making the most efficient use of available donor kidneys, eliminating the possible use of bad donor kidneys, providing an accurate measure of expected post-transplant renal function, and allowing better distinction between post-transplant immunological rejection and ischemic-induced acute renal failure.

Detailed description

What will be assessed: Kidney pathology will be assessed. Specifically, optical coherence tomography (OCT) will be used to observe the pathology of the kidney uriniferous tubules. The proximal convoluted tubules that make up most of the kidney uriniferous tubules and parenchyma in the outer cortex of the kidney (i.e., the portion of the kidney subjacent to the outer kidney capsule) are sensitive indicators of damage to the kidneys. When damaged due to ischemia (i.e., a lack of blood flow), these tubules swell and cellular debris is released into the lumens of these tubules. Why is this data important: Damage to the kidney proximal tubules, known as acute tubular necrosis (ATN), is the most common cause of poor post-transplant kidney function following transplant. It has been shown that determining the extent of ATN is a good indicator of post-transplant renal function. How will the data be collected: The histopathology describe above (i.e., the pathology of the kidney tubules) will be collected using optical coherence tomography (OCT). OCT is a rapidly emerging imaging modality that can function as a type of optical biopsy, providing non-invasive cross-sectional images of tissue architectural pathology in situ and in real-time. OCT is similar to ultrasound, but uses light waves instead of sound waves to obtain high-resolution imaging. The ability of OCT of obtain high-resolution images is necessary in order to observe the pathological changes describe above (i.e., damage to the kidney tubules). Algorithms will be developed as a result of this investigation in order to assist in the prediction of ATN and post-transplant kidney function. What factors will be measured to determine post-transplant kidney function: The factors that will be used to measure post-transplant renal function include serum creatinine, BUN and glomerular filtration rates (GFR). This data will be collected by examining the surgical and laboratory reports for each patient. The data will be collected daily for the first two weeks following transplant and biweekly for the next six months following transplant. Six months following transplant, this data will be collected every 3 months until conclusion of study (i.e., 4 years). The patient data will be stored on password-protected files on a password-protected computer. The data will be available only to the principal investigator and the co-investigators in this study. A nephrologist fellow who will report directly to the principal investigator will collect the data. The principal investigator will verify data accuracy and protocol compliance. A biostatistician who will be blinded as to patient identity will independently analyze the data. If the data is published, only the parameters listed above and related to post-transplant renal function will be reported. No names will be associated with publication of the collected kidney transplant data. The principal investigator and the biostatistician will monitor this data and any indications of potential harm to the patient will be reported immediately to the Institutional Review Board (IRB).

Interventions

PROCEDUREProcedure/Surgery: Transplantation: OCT of Kidney Transplant

Device: Optical Coherence Tomography of Kidney Transplant

Sponsors

Georgetown University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

Undergoing Kidney Transplant -

Exclusion criteria

None \-

Design outcomes

Primary

MeasureTime frameDescription
Non-Invasive Evaluation of Transplant Kidney using OCTUp to 4 yearsThe outcome from these studies is to show significance differences in the donor kidneys of the three patient populations (i.e., immediate graft function, slow graft function and delayed graft function) using OCT imaging.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026