Skip to content

Comparing USCOM and Echocardiographic Hemodynamic Measurements in Children (CUE Study)

Evaluating Agreement Between USCOM and 2D-echocardiographic Hemodynamic Measurements in Pediatric Patients

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02083172
Enrollment
78
Registered
2014-03-11
Start date
2014-07-31
Completion date
2016-01-31
Last updated
2016-03-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Critical Illness, Hemodynamically Stable

Keywords

USCOM (UltraSound Cardiac Output Monitor), 2D echocardiography, agreement, pediatrics

Brief summary

The primary objective of this study is to evaluate the agreement between hemodynamic measurements obtained using the Ultrasound Cardiac Output Monitor (USCOM®; USCOM Ltd., Sydney, Australia), and reference standards as determined by 2 Dimensional echocardiography (2D-echo) measurements in a group of hemodynamically stable and unstable pediatric patients.

Detailed description

2D-echo is the standard-of-care tool for non-invasive hemodynamic assessments in children. The use of 2D-echo requires highly trained personnel, and assessments may take anywhere between 30-45 minutes. The feasibility of real time hemodynamic assessments is therefore limited with 2D-echo. USCOM has been introduced as a non-invasive bedside hemodynamic monitoring tool that utilizes continuous-wave Doppler ultrasound. As USCOM is easily portable, and measurements take only several minutes and can be conducted by trained physicians or nurses, it has become an attractive method of real time hemodynamic monitoring of unstable patients. While USCOM validation studies have been conducted in adult, neonatal and pediatric populations, the following concerns have been raised: a) Pediatric data on the agreement between USCOM and other standard methods of CO measurement (i.e. 2D-echo, pulmonary artery catheterization) are conflicting with some studies reporting acceptable agreement, while others report poor agreement ; b) USCOM validation and agreement studies were previously conducted in primarily hemodynamically stable populations. Its performance in hemodynamically unstable and mechanically ventilated patients has not been studied to date in the pediatric population.USCOM is currently being promoted as a real-time tool for assessing hemodynamic status, and directing the care of unstable children without adequate evidence. Therefore, this study is essential to inform the validity of USCOM and whether it can or should be used when 2D-echo for real time hemodynamic monitoring in children is not feasible or available.

Interventions

DEVICEUltrasound Cardiac Output Monitor and 2 D-Echo

Hemodynamic measurements obtained by 2D-Echo and USCOM will be compared.

Sponsors

McMaster University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Months to 18 Years
Healthy volunteers
No

Inclusion criteria

* Age under 18 years * Patient fulfills clinical criteria for either study cohort * Most Responsible Physician has ordered an ECHO study on the patient * Written informed consent by parents/legal guardian/substitute decision maker, and assent where appropriate * Patients with normal cardiac structure, no pre-existing primary cardiovascular disease or hemodynamically insignificant shunt lesions (i.e. hemodynamically insignificant Atrial Septal Defect/Patent Foramen Oval and Ventricular Septal Defect

Exclusion criteria

* Age ≥ 18 years * Premature infants (born \<37 weeks gestation) admitted to the Neonatal Intensive Care Unit * Known co-existing primary cardiac anomalies (i.e. aortic or pulmonary valve stenosis or regurgitation, Aortic Valve regurgitation, shunt lesions save for those mentioned above, and pericardial effusion) * Prior enrollment in study

Design outcomes

Primary

MeasureTime frameDescription
Agreement in hemodynamic measurements obtained by USCOM and 2D-Echo respectively, in hemodynamically stable childrenWithin 30 minutes of first measurement methodHemodynamic measurements are include cardiac output (CO), Stroke Volume (SV),Aortic cross sectional area (Ao CSA), Preload (SVV%) Inferior Vena cava Collapsibility index (IVC), Inotropy (SMI) and (EF)

Secondary

MeasureTime frameDescription
Agreement in hemodynamic measurements obtained by USCOM and 2D-Echo, in hemodynamically unstable children, and children receiving positive pressure ventilation respectivelyWithin 30 minutes of first measurement methodHemodynamic measurements are include Cardiac Output (CO), Stroke Volume(SV), Preload (SVV%) and IVC collapsibility Index, Inotropy

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026