Validation of Triggered EMG Values for Pedicle Screws Using a Powered Screwdriver

Validation of Triggered EMG Values for Pedicle Screws Using a Powered Screwdriver

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02064101
Enrollment
27
Registered
2014-02-17
Start date
2014-02-28
Completion date
2015-07-31
Last updated
2016-10-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Scoliosis

Keywords

Scoliosis, EMG, Pedicle screw, Neuromonitoring

Brief summary

Previous studies have shown how triggered electromyogram (EMG) pedicle screw stimulation can be used to effectively test correct pedicle screw placement in the lumbar and thoracic vertebrae. Most papers agree that if more than 6mA of current are needed to elicit a response the screw is correctly placed in the bone. If there is a response with less than 6mA there is a strong likelihood of a breach of the pedicle wall or invasion of the spinal canal. Typically this triggered EMG stimulation is done after all the screws have been placed with a ball-tipped probe and is paired with intraoperative fluoroscopy to ensure correct placement of the screws. Another method of testing the current for each screw is with a powered screwdriver, which can stimulate and give a reading as the surgeon places each screw. Both of these methods are currently used by surgeons, however the powered screwdriver has been found to be a faster method. The investigator's aim with this study is to compare these two methods of testing triggered EMG values. The investigators plan on doing this by testing each screw with both the ball-tipped probe and the powered screwdriver, in order to see if there are any statistically significant differences between the readings.

Detailed description

The purpose of the study is to compare two methods of testing triggered EMG values. All study measurements will be recorded during the surgical procedure. No follow up is required with the patient involved and no personal health information will be recorded from the patients.

Interventions

PROCEDURESpinal Fusion

The investigators are studying the use of triggered EMG via the IPC POWEREASE screwdriver (Product Codes HBE, HWE, GWF) during spinal fusion surgery in adolescent idiopathic scoliosis by comparing it to the traditional triggered EMG OrthoMon probe system (Product Codes GWF, IKN).

Sponsors

University of Colorado, Denver
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
8 Years to 21 Years
Healthy volunteers
No

Inclusion criteria

* between the ages of 8-21 years * diagnosis of adolescent idiopathic scoliosis (AIS) * scheduled to receive a spinal fusion

Exclusion criteria

* diagnosis of any other type of scoliosis (infantile, juvenile, congenital, neuromuscular, etc)

Design outcomes

Primary

MeasureTime frameDescription
Triggered EMG valueWill be recorded during surgery, fully assessed after data collection is completeThe triggered EMG value the investigators are measuring is not being evaluated with respect to the individual patient. Rather, the investigators are studying the devices themselves so once all readings are collected (which will take readings from multiple screws in multiple patients) the outcome measure will be assessed.