Skip to content

Digestive Endoscopy Suite Radiation Controlling Protective Strategies

A Prospective Double-blind, Randomized, Sham-controlled Trial to Evaluate the Effect of a Lead Free Drape on Scatter Radiation Exposure to Endoscopy Staff During Endoscopic Retrograde Cholangiopancreatography

Status
Completed
Phases
Early Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02063841
Acronym
D-ERCP
Enrollment
2
Registered
2014-02-14
Start date
2013-08-31
Completion date
2013-11-30
Last updated
2015-08-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Radiation Exposure

Brief summary

ERCP is associated with radiation exposure to the endoscopist and staff, which may be significant at high volume programs despite the use of lead aprons. We hypothesize that draping of the fluoroscopy image intensifier may significantly reduce staff radiation exposure and help achieve implementation of the ALARA (As Low As Reasonably Achievable) principle.

Detailed description

A total of 100 consecutive ERCP procedures were randomly assigned to the radiation-attenuating or sham drape in a 1:1 ratio. There were 2 subjects, the endoscopists performing ERCP and the nurse assisting in the procedure.

Interventions

DEVICElead-free protective drape containing bismuth and antimony (RADPAD®)
DEVICEsterile identical sham drape

Sponsors

Yale University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
PREVENTION
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
45 Years to 50 Years
Healthy volunteers
No

Inclusion criteria

* All the ERCP procedures done by the same endoscopist and nurse are enrolled * Patients age \>19

Exclusion criteria

* Fluoroscopic procedures other than ERCP were excluded.

Design outcomes

Primary

MeasureTime frameDescription
Amount of radiation exposureLength of Endoscopic retrograde cholangiopancreatography, average 5 minutesComparing the use of a lead-free protective drape containing bismuth and antimony and a sterile sham protective drape, radiation dose (RD) was measured at 3 different sites (endoscopist's eye (1) and thyroid (2), and assisting nurse's thyroid (3)) with personal dosimeters placed outside of eyeglass frames and the thyroid shield. The unit of measurement is each event. The subject was subjected to radiation during 100 Endoscopic retrograde cholangiopancreatography procedures.Both groups used standard of care lead protection.

Secondary

MeasureTime frameDescription
Estimate cumulative annual radiation riskLength of Endoscopic retrograde cholangiopancreatography, average 5 minutesComparing the use of a lead-free protective drape containing bismuth and antimony and a sterile sham protective drape, radiation dose (RD) was measured at 3 different sites (endoscopist's eye (1) and thyroid (2), and assisting nurse's thyroid (3)) with personal dosimeters placed outside of eyeglass frames and the thyroid shield. The unit of measurement is each event. The subject was subjected to radiation during 100 endoscopic retrograde cholangiopancreatography procedures. The cumulative estimated annual absorbed radiation dose was estimated from the data collected during the study time frame.

Countries

United States

Outcome results

None listed