Skip to content

Infrared Lymphangiography as a Method of Sentinel Node Identification

Infrared Lymphangiography as a Method of Sentinel Node Identification

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02057393
Acronym
SPY-SN
Enrollment
89
Registered
2014-02-07
Start date
2014-06-30
Completion date
2016-02-29
Last updated
2017-07-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Melanoma, Sentinel Node

Keywords

Melanoma, Sentinel node biopsy, Indocyanine green, Real time lymphangiography

Brief summary

The initial treatment for most people with melanoma involves wide excision of the skin and sentinel node biopsy. As with other cancers, the status of the sentinel node provides important prognostic information to the patient and physician. Sentinel node biopsy was first developed using only a blue dye. Technetium99, a radioactive protein, was added later and provides the ability to image the patient and identify relevant lymph node basins. For the last 15 years or so, the standard method of SLN localization includes both tech99 and blue dye. While the rates of localization overall are excellent, these methods each have drawbacks. We are investigating a new method of finding sentinel nodes that uses a green dye that has an infrared signal. Our hypothesis is that indocyanine green (ICG) and real time lymphangiography is equivalent to technetium99 and methylene blue in identifying sentinel nodes (SLN) in patients with melanoma.

Detailed description

Patients with melanoma of the trunk or extremities were prospectively enrolled in this trial. Patients with head and neck melanoma were excluded from this study based on our pilot experience. ICG is poorly visualized through muscle, and there seems to be high background uptake in the parotid gland; both of these features limit the utility of ICG and fluorescence imaging. All subjects had T1b or greater melanoma, and met current National Comprehensive Cancer Network (NCCN) guidelines for sentinel node biopsy. All subjects had injection of tech99 and lymphangiography prior to surgery, and injection of indocyanine green (ICG) and methylene blue dye (MB) in the operating room. We utilized methylene blue dye for all subjects due to poor availability of isosulfan blue for a period of time, and to maintain consistency in the trial. Up to 1ml of MB was injected, and 0.9ml ICG (2.5 mg/ml). The ICG and MB were injected into the dermis separately, after induction of anesthesia and prior to prepping the patient. Each lymph node basin was examined with the gamma probe and imaged with the SPY Elite (Novadaq) prior to making skin incision, with assessment of the visibility of ICG through the skin (yes or no). Once incision was made, the basin was periodically imaged with SPY, or dissection was carried out with real time lymphangiography until the sentinel node was identified. The camera of the SPY machine is positioned over the basin, with the image projected onto a monitor. Similar to laparoscopy, the surgeon can watch the image and operate at the same time. Each sentinel node was assessed for the presence of each dye. A lymph node with any one of the dyes present was considered a sentinel node, and was resected. Fluorescence and blue dye were measured as yes or no, and not quantitated. Additional data collected includes demographic data, the dose of ICG and MB given, adverse effects from any dye, the total number of sentinel nodes identified and the number of malignant sentinel nodes. Pair-wise comparisons were made between the three dyes regarding the number of detected sentinel nodes, and the number of detected metastatic nodes.

Interventions

DRUGIndocyanine green

Subjects receive 0.9ml of ICG subcutaneously about the primary melanoma. The ICG has an infrared signal that is detected with the SPY Elite system (Lifecell). The ICG travels through the lymphatics to the sentinel node.

Technetium99 is a standard, widely used radiopharmaceutical that is injected subcutaneoulsy about the primary melanoma site. Lymphoscintigraphy is performed to identify the draining nodal basin, and a gamma probe is used in the operating room to track the radioactive signal and find the sentinel node.

DRUGMethylene blue

Subjects receive 0.5-2ml of methylene blue subcutaneously about the primary melanoma at the time of surgery. The sentinel node should turn blue, which is visible with the naked eye.

Sponsors

Milton S. Hershey Medical Center
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients must have histologically or cytologically confirmed melanoma. * All patients with melanoma of the arm, leg or trunk who qualify for a sentinel node biopsy based on the characteristics of their primary tumor are eligible to participate. Patients with melanoma that is T1b or greater are recommended to have a sentinel node biopsy. * Age \>18 years. Melanoma is extremely uncommon in children, this disease is not relevant in this age group. * The effects of IC-Green on the developing human fetus at the recommended therapeutic dose are unknown. For this reason women of child-bearing potential and men must agree to use adequate contraception (hormonal or barrier method of birth control; abstinence) prior to study entry and for the duration of study participation. Should a woman become pregnant or suspect she is pregnant while she or her partner is participating in this study, the patient should inform the treating physician immediately. * Ability to understand and the willingness to sign a written informed consent document.

Exclusion criteria

* Patients with melanoma on the head or neck are excluded * History of allergic reactions attributed to compounds of similar chemical or biologic composition to IC-Green, sodium iodide or other agents used in the study. * Pregnant women are excluded from this study

Design outcomes

Primary

MeasureTime frameDescription
Equivalence of ICG and Real Time Lymphangiography to technetium99 and Blue Dye in Localizing Sentinel Nodes2 weeksThe primary outcome measure is the accuracy of indocyanine green (ICG) and real time lymphangiography to identify sentinel nodes (SLN) in patients with melanoma, compared to tech99 and methylene blue. Tech99 is considered the standard, for comparison. Accuracy is being determined by the number of sentinel nodes that are identified with ICG, compared to tech99 or methylene blue.

Countries

United States

Participant flow

Participants by arm

ArmCount
Indocyanine Green
Single arm study, each subject receives 0.9ml ICG, methylene blue and technetium 99. Indocyanine green: Subjects receive 0.9ml of ICG subcutaneously about the primary melanoma. The ICG has an infrared signal that is detected with the SPY Elite system (Lifecell). The ICG travels through the lymphatics to the sentinel node. Technetium99: Technetium99 is a standard, widely used radiopharmaceutical that is injected subcutaneoulsy about the primary melanoma site. Lymphoscintigraphy is performed to identify the draining nodal basin, and a gamma probe is used in the operating room to track the radioactive signal and find the sentinel node. Methylene blue: Subjects receive 0.5-2ml of methylene blue subcutaneously about the primary melanoma at the time of surgery. The sentinel node should turn blue, which is visible with the naked eye.
87
Total87

Withdrawals & dropouts

PeriodReasonFG000
Overall StudyPatient did not meet criteria1
Overall StudyWithdrawal by Subject1

Baseline characteristics

CharacteristicIndocyanine Green
Age, Continuous65 years
BMI28 kg/m2
Race and Ethnicity Not Collected— Participants
Region of Enrollment
United States
87 Participants
Sex: Female, Male
Female
45 Participants
Sex: Female, Male
Male
42 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 87
other
Total, other adverse events
0 / 87
serious
Total, serious adverse events
0 / 87

Outcome results

Primary

Equivalence of ICG and Real Time Lymphangiography to technetium99 and Blue Dye in Localizing Sentinel Nodes

The primary outcome measure is the accuracy of indocyanine green (ICG) and real time lymphangiography to identify sentinel nodes (SLN) in patients with melanoma, compared to tech99 and methylene blue. Tech99 is considered the standard, for comparison. Accuracy is being determined by the number of sentinel nodes that are identified with ICG, compared to tech99 or methylene blue.

Time frame: 2 weeks

ArmMeasureValue (MEAN)Dispersion
Indocyanine GreenEquivalence of ICG and Real Time Lymphangiography to technetium99 and Blue Dye in Localizing Sentinel Nodes1.87 number of sentinel nodes per patientStandard Deviation 0.95

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026