Detecting Lung Infections Through Vibration

Feasibility and Optimization of High Frequency Oscillation (HFO) for Detection of Lung Infections

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02056860
Enrollment
16
Registered
2014-02-06
Start date
2014-02-28
Completion date
2015-12-31
Last updated
2016-03-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lung Infection

Keywords

cystic fibrosis

Brief summary

The purpose of this study is to test a lung air vibrator device for vibrating air inside the lung. This exploratory diagnostic trial will test a novel and non-invasive means of detecting lower airway infections using exhaled breath sample.

Detailed description

This study has two phases. Once the subject has consented phase 1 will start by the subject breathing air out of their lungs into the device. Next, the subject will simply breathe through the mouthpiece with the machine turned on and take samples of exhaled air. In phase 2, the subjects will breathe air out of their lungs into the device for 15 minutes. Next, the subject will simply breathe through the mouthpiece with the machine turned on and take samples of exhaled air for 15 minutes.

Interventions

PROCEDUREGroup 1 will receive 15 Hz

Group 1 (n=30), these subjects will receive 10 minutes of High Frequency Oscillation at 15 Hz at .75 cm on day 1. Then will have a 24 hour washout. On day 2 will receive 10 minutes of low Frequency Oscillation at 15 Hz at 1.25 cm.

PROCEDUREGroup 2 will receive 30 Hz

Group 2 (n=30), these subjects will receive 10 minutes of High Frequency Oscillation at 30 Hz at .75 cm on day 1. Then will have a 24 hour washout. On day 2 will receive 10 minutes of low Frequency Oscillation at 30 Hz 1.25 cm.

PROCEDUREGroup 3 will receive 60 Hz

Group 3 (n=30), these subjects will receive 10 minutes of High Frequency Oscillation at 60 Hz .75 cm on day 1. Then will have a 24 hour washout. On day 2 will receive 10 minutes of low Frequency Oscillation at 60 Hz at 1.25 cm.

PROCEDUREGroup 4 will receive 100 Hz

Group 4 (n=30), these subjects will receive 10 minutes of High Frequency Oscillation at 100 Hz at .75 cm on day 1. Then will have a 24 hour washout. On day 2 will receive 10 minutes of low Frequency Oscillation at 100 Hz at 1.25 cm.

PROCEDUREPhase II Optimal Frequency

Participants in Phase II will undergo 10 minutes of HFO at the optimal frequency as determined during Phase I.

Sponsors

University of Florida
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

* Age 18-50

Exclusion criteria

* History of major respiratory compromise (except cystic fibrosis if included within cystic fibrosis cohort)

Design outcomes

Primary

MeasureTime frameDescription
Optimal Operating Conditions for HFO Device6 monthsFollowing informed consent procedures, participants will be randomly assigned (much like a flip of a coin) to one of four experimental groups in order to test the effects of various frequencies of HFO on the size and concentration of particles obtained from EB. Group 1 (n=30) will receive 10 minutes of HFO at 15 Hz. Group 2 (n=30) will receive an identical course of HFO with the frequency set at 30 Hz. Group 3 (n=30) will receive HFO at 60 Hz and Group 4 (n=30) at 100 Hz. Participants will be tested on two separate days in order to systematically vary HFO intensity. Once again, much like a flip of a coin, each participant will be randomly assigned to receive HFO at either a low (0.75 cmH2O) or high (1.25 cm H2O) intensity on HFO Day 1. Participants receiving low intensity HFO on Day 1 will receive high intensity HFO on Day 2, and vice versa. Between HFO Testing Day 1 and 2 there will be a washout period of at least 24 hours.

Secondary

MeasureTime frameDescription
Particle size and distribution from exhaled breathOne yearThe exhaled air will be directed to a culturing media in place of the Sizer for collection of the droplets during two conditions: tidal breathing without oscillation (control) and tidal breathing with oscillation (experimental). The samples collected in the medium will later be cultured in a lab to determine the microbial species and their abundances. The purpose of Phase II experiments is to characterize the biological constituents produced from the oscillation enhanced sampling and contrast these constituents with those obtained during non-oscillation enhanced sampling. We hope to determine if the addition of oscillation increases the variety and abundance of microbial species able to be extracted from exhaled breath.

Countries

United States

Outcome results

None listed