Skip to content

Variability of Hemoglobin Levels After Kidney Transplantation

A Retrospective, Observational Study to Evaluate Hemoglobin Variability in Kidney Transplant Recipients With Chronic Renal Anemia.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02041208
Enrollment
368
Registered
2014-01-20
Start date
2012-03-31
Completion date
2012-10-31
Last updated
2014-01-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Renal Anemia

Keywords

Chronic renal anemia, Hemoglobin, Kidney transplant

Brief summary

The purpose of this study es to determine hemoglobin variability in kidney transplant recipients with chronic renal anemia.

Detailed description

The primary endpoint of the study is hemoglobin level variability. For determination of this variability, the following patterns of hemoglobin level change will be established: * Target range hemoglobin (TRH): patients with hemoglobin values in the range of 11.0-12.0g/dl throughout the study period. * Low hemoglobin (LH): patients with levels below 11.0g/dl * High hemoglobin (HH): patients with levels above 12.0g/dl * Low-amplitude fluctuation with low hemoglobin (LALH): patients with at least one measurement of hemoglobin levels \<11.0g/dl and at least one measurement in the range of 11.0-12.0g/dl, but without hemoglobin measurements \>12.0g/dl. * Low-amplitude fluctuation with high hemoglobin (LAHH): patients with at least one measurement of hemoglobin levels \>12.0g/dl and at least one measurement in the range of 11.0-12.0g/dl, but without hemoglobin measurements \<11.0g/dl. * High-amplitude fluctuation (HAH): patients with at least one measurement of hemoglobin levels \<11.0g/dl and at least one measurement \>12.0g/dl. Secondary objectives: * To determine potential factors influencing hemoglobin variability. * To assess the influence of hemoglobin variability on cardiovascular risk of patients according to the REGICOR function at the end of the study period.

Interventions

PROCEDUREkidney transplantation

kidney transplantation

Sponsors

Sociedad Española de Trasplante
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients aged \> or = 18 years. * Kidney transplant recipients with chronic renal failure stage 3 (glomerular filtration rate: 30-59ml/min/1.73m2), 4 (glomerular filtration rate: 15-29ml/min/1.73m2) or 5 (glomerular filtration rate: \<15ml/min/1.73m2) at the start of the study follow-up period. * Diagnosis of anemia and drug treatment initiated or changed subsequent to June 29, 2010 (date on which the latest recommendation by European Renal Best Practice on the target range for hemoglobin levels were published) * Patients capable of giving their informed consent to participate in the study and who agree to participate by signing the informed consent form.

Exclusion criteria

* Patients whose medical history lacks measurements of hemoglobin levels every three months (±1 month) during the year of study follow-up.

Design outcomes

Primary

MeasureTime frameDescription
The primary endpoint of the study is hemoglobin level variabilitythe study includes the retrospective collection of information from the medical records of patients over a period of one year.For determination of this variability, the following patterns of hemoglobin level change will be established: * Target range hemoglobin (TRH): patients who maintain hemoglobin values in the range of 11.0-12.0g/dl throughout the study period. - Low hemoglobin (LH): patients with hemoglobin levels below 11.0g/dl. * High hemoglobin (HH): patients with hemoglobin levels above 12.0g/dl. * Low-amplitude fluctuation with low hemoglobin (LALH): patients with at least one measurement of hemoglobin levels \<11.0g/dl and at least one measurement in the range of 11.0-12.0g/dl, but without hemoglobin measurements \>12.0g/dl. * Low-amplitude fluctuation with high hemoglobin (LAHH): patients with at least one measurement of hemoglobin levels \>12.0g/dl and at least one measurement in the range of 11.0-12.0g/dl, but without hemoglobin measurements \<11.0g/dl. * High-amplitude fluctuation (HAH): patients with at least one measure of hemoglobin levels \<11.0g/dl and at least one measurement \>12.0g/dl

Secondary

MeasureTime frameDescription
Estimation of cardiovascular risk of patientsat the end of the study period (one year after the start of data recording)according to the REGICOR function (acronym Girona Heart Registry)
Potential factors influencing hemoglobin variabilityBoth baseline data and the changes recorded on the visit at month 12 will be considered.Demographic and anthropometric data, comorbidities, concomitant medication, and data on transplant, chronic renal failure, renal anemia treatment and possible hospitalizations.

Countries

Spain

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026