Skip to content

Real Time In-Vivo Dosimetry For Gynecologic Brachytherapy

Real Time In-Vivo Dosimetry For Gynecologic Brachytherapy

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02040155
Enrollment
16
Registered
2014-01-20
Start date
2014-02-28
Completion date
2015-08-31
Last updated
2017-05-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cancer of the Cervix, Cancer of the Endometrium

Brief summary

This is an observational study. The purpose is to determine the feasibility of using a novel nano-scintillator fiber-optic dosimeter (nanoFOD) for the real time dosimetric monitoring of brachytherapy treatment. Women with gynecologic cancers treated with brachytherapy as part of their standard therapeutic regimen will represent the study population.

Detailed description

Brachytherapy is a curative treatment for many malignancies, brachytherapy delivers a high radiation dose to a very small and well-specified target within a patient with cancer. Yet there is no current convenient, inexpensive, real time method of confirming the radiation dose delivered. There is no current monitoring or fail-safe device for radiation oncologists and their patients if the radiation dose becomes too high, especially to radiation sensitive organs, or conversely if the target receives too little dose.High dose-rate(HDR) brachytherapy is a highly advanced radiation-based cancer treatment, where a very small radioactive source, Iridium-192, is placed in or near the tumor through a catheter or channel. This provides a high radiation dose to the tumor in 5-15 minutes with a precise location, while minimizing radiation exposure to surrounding tissue and organs. This protocol will determine the feasibility of using a novel nano-material based fiber-optic dosimeter (nanoFOD) device, with dimensions less than 1 mm wide, to measure real-time, pin-point, in-vivo radiation dose given during radiation therapy treatments. The size of the device allows placement through a catheter or channel near areas of interest, or within already placed brachytherapy delivery catheters.

Interventions

DEVICENovel nano-scintillator fiber-optic dosimeter (nanoFOD)

This is an observational study whose purpose is to determine the feasibility of using a novel nano-scintillator fiber-optic dosimeter (nanoFOD) for the real time dosimetric monitoring of brachytherapy treatment.

Sponsors

Wallace H. Coulter Foundation
CollaboratorOTHER
Duke University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Histologically documented neoplasm of the female genital tract. * Planned brachytherapy as part of standard of care treatment. * Age \> 18 years * Able to provide and execute informed consent

Exclusion criteria

* Any clinical scenario in which the nanoFOD placement or reading would compromise the treatment efficacy, or endanger the patient in any way.

Design outcomes

Primary

MeasureTime frameDescription
Measure dosimetric accuracy of the device with reference to a commercially available dosimeter.24 monthsThis will only be possible in a subset of women whose implant geometry will result in a radially symmetric dose cloud (i.e. vaginal cylinder cases) so that both the nanoFOD and the reference dosimeter may be placed in a position expected to have the same, or closely similar dose.

Secondary

MeasureTime frameDescription
Confirm feasibility of clinical application of the nanoFOD for dosimetric monitoring of brachytherapy with complex geometry implants.24 monthsFeasibility in this context will mean ease of clinical use (subjective), lack of device failures, and accordance of the nanoFOD dosimetric reading with the planned dose as calculated by the planning software.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026