Feasibility Study Into Adjustment of the Radiation Beam to Account for Prostate Motion During Radiotherapy.

Phase I Feasibility Study of Prostate Cancer Radiotherapy Using Realtime Dynamic Multileaf Collimator Adaptation and Radiofrequency Tracking (Calypso)

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02033343
Acronym
CALYPSO
Enrollment
30
Registered
2014-01-10
Start date
2013-10-31
Completion date
2018-02-28
Last updated
2021-06-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Prostate Cancer

Keywords

Prostate Cancer, Real-time tracking, Radiotherapy, Dynamic Multileaf Collimator

Brief summary

The purpose of this study is to monitor movement of the prostate during radiotherapy and adjust the radiation beam to account for any motion seen. This will increase the radiation dose to the prostate and decrease the dose to the rectum and bladder.

Detailed description

Prostate cancer now accounts for one third of all new cancer diagnoses in men and approximately 30% of men will have external beam radiotherapy as their primary local therapy. Prostate motion during radiotherapy can be divided into interfraction and intrafraction motion. Interfraction motion has been well established and has been largely overcome by daily online image verification with either ultrasound, online CT or implanted fiducial markers, however motion during the radiation beam on time (intrafraction motion) is not corrected and can be the cause of significant errors in radiation dose delivery. The most common technology utilised in 2012 to allow prostate gating is the Calypso system. The Calypso system consists of implantable electromagnetic transponders, an array that contains source and receiver coils, computers for data analysis and display purposes, and an infrared camera system to localise the electromagnetic array in the treatment room. The array is placed over the patient, and the source coil in the array emit an electromagnetic signal that excites the transponders. Once the transponders are excited, the source coils are turned off and the receiver coils detect the signal emitted from the excited transponders. This process is repeated at a rate of 10 Hz, providing a realtime radiofrequency localisation of the prostate triangulating three implanted beacons. The current study will investigate using the continuous prostate positioning data from Calypso to integrate with the treatment beam delivery and allow real-time adaptation based on the prostate motion. This is called Realtime Dynamic Multileaf Collimator (DMLC) tracking. In this technique the multileaf collimator motion is altered in the gantry head in real time during beam delivery to account for the measured prostate motion. The proposed study is examining the dosimetric impact of accounting for intrafraction motion with Calypso and DMLC tracking. We hypothesise the improvements in delivered prostate dose with DMLC tracking will be even greater than gating. This improved treatment delivery will ensure that the prostate cancer receives the appropriate dose and that normal tissues are spared from extra radiation.

Interventions

RADIATIONProstate cancer radiotherapy using real-time tracking

Radiotherapy delivered using Calypso radiofrequency emitting beacon guided real-time prostate localisation and beam adjustment using Dynamic Multi-leaf Collimator tracking software.

Sponsors

University of Sydney
CollaboratorOTHER
Royal North Shore Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
MALE
Age
35 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

* Patients undergoing external beam radiotherapy at Northern Sydney Cancer Centre * Histologically proven prostate adenocarcinoma * Prostate Specific Antigen (PSA) obtained within 3 months prior to enrolment. * Patient must be able to have Varian Calypso beacons placed in the prostate (if on anticoagulants, must be cleared by Local Medical Officer or cardiologist). * ECOG performance status 0-2 * Ability to understand and the willingness to sign a written informed consent document. * Body habitus enabling Calypso tracking (as per Calypso Determining a Patient's Localisation Designation & Orientation before implantation) * Prostate dimension that allows leaf span with tracking margin of ±8mm

Exclusion criteria

* Previous pelvic radiotherapy * Prior total prostatectomy * Pacemaker * Implantable defibrillator * Insulin infusion pump * Hip prosthesis * Unwilling or unable to give informed consent * Unwilling or unable to complete quality of life questionnaires.

Design outcomes

Primary

MeasureTime frameDescription
Percentage of fractions being successfully delivered with Calypso-guided tracking.2 yearsThe primary endpoint of this Pilot study is to evaluate the feasibility of implementing realtime adaptive radiotherapy using DMLC. This will be assessed as greater than 95% of fractions being successfully delivered (no equipment failures and tracking MLC follows beacons) with Calypso-guided tracking.

Secondary

MeasureTime frameDescription
Improvement in overall beam-target geometric alignment.2 yearsGeometric alignment will be measured as average difference between beacon centroid and shifted MLC against original MLC.
Improvement in dosimetric coverage of prostate and normal healthy structures.2 yearsDosimetric improvement will be assessed by applying the methods of Poulsen to reconstruct delivered dose distributions for each fraction of patient cohort and summed total dose. Preliminary data demonstrates dose reconstruction to follow the planned dose distribution, potentially even for ultrahypofractionated cases with longer treatment duration and Flattening Filter Free (FFF) delivery with larger potential delivery error per time increment.
Acute toxicityAssessed up to 12 weeks post treatmentPortion of patients with grade 3 or greater genitourinary or gastrointestinal toxicity assessed using the Modified Radiation Therapy Oncology Group (RTOG) Toxicity Scale.
Late toxicityUp to five yearsOngoing reporting of gastrointestinal and genitourinary toxicity of the DMLC tracking cohort will be compared to matched pair controls using the modified RTOG scale.
Biochemical controlUp to five yearsOngoing biochemical control of the DMLC tracking cohort will be compared to matched pair controls using Prostate Specific Antigen (PSA).