Skip to content

Neurologic Examination of Wide and Narrow Tourniquets

Nerve Function in Healthy Human Volunteers With Two Different Tourniquets

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02023476
Acronym
HEM
Enrollment
18
Registered
2013-12-30
Start date
2010-04-30
Completion date
2010-09-30
Last updated
2014-01-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Nerve Compression

Brief summary

Nerve injury is a serious potential complication associated with the clinical use of exsanguinating tourniquets in surgery. Recently, a novel narrow tourniquet has been proposed, with the claim that it may cause less compression of the nerves. We performed an in vivo comparison of a standard wide tourniquet with the new, narrow tourniquet. Our study specifically looked at neurologic markers in the upper extremity.

Detailed description

The HemaClear ™ OHK Medical Device HemaClear™, approved by FDA, consists of a silicon ring wrapped in a stockinet sleeve and pull straps (Fig.1). It performs three functions - blood removal (exsanguinations), arterial flow occlusion, and placement of sterile stockinet 30. The ring is placed on the extremity and then straps are pulled proximally. The silicone ring rolls up the limb while the stockinet sleeve unfolds onto the limb. During the rolling up process, the ring exerts pressure and squeezes the blood away from the limb. Application of the device takes less than a minute. The technique behind this device is fundamentally different from classic pneumatic tourniquets, as pressure is exercised by only a single silicon ring so that the profile is very small. Zimmer A.T.S.®3000 The A.T.S.®3000 is an automatic broad tourniquet system with a Limb Occlusion Pressure (LOP) feature. It is the latest innovation in tourniquet technology and has FDA approval. It was invented by McEwen 4 and the basic function is described in several clinical trials and publications 28. The main difference to other pneumatic tourniquets is the LOP and the Recommended tissue pressure (RTP) feature. These parameters are suitable to optimize the pressure force on the tourniquet for each individual patient. The LOP is detected before inflating the tourniquet and the RTP is the LOP plus a safety margin to guarantee a blood free field (Operator & Service Manual Zimmer A.T.S.® 3000 Automatic tourniquet system REF 60-3000-101-00).

Interventions

RADIATIONMRI

MRI- imaging on the upper arm

Sponsors

Medical University of Vienna
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 45 Years
Healthy volunteers
Yes

Inclusion criteria

* self defined Caucasian * clinically healthy * BMI of ≤ 30, * a systolic arterial blood pressure ≤190 mmHg, * no rash or dermatologic condition or tattoos which may interfere with the placement site * no neurovascular impairment. * all female participants received a pregnancy test at the initial screening visit. * Study population was restricted to Caucasians to enable an assessment of device caused redness or skin lesions, not possible in a mixed study population.

Design outcomes

Primary

MeasureTime frameDescription
Nerve compression20 Minutesmg/mm2

Secondary

MeasureTime frame
Nerve compression20 minutes