Skip to content

Comparison of BuMA eG Based BioDegradable Polymer Stent With EXCEL Biodegradable Polymer Sirolimus-eluting Stent in Real-World Practice

A Prospective, Multicenter, RAndomized, CoNtrolled, Study Comparing the Safety and Efficacy Between BuMA eG Based BioDegradable Polymer Stent and EXCEL Biodegradable Polymer Sirolimus-eluting Stent in ReAl-World Practice (PANDA-III)

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02017275
Acronym
PANDA-III
Enrollment
2348
Registered
2013-12-20
Start date
2013-11-30
Completion date
Unknown
Last updated
2016-03-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

PANDA III is sought to investigate the safety and efficacy of a PLGA-polymer with electro-grafting base layer sirolimus-eluting stent (SES) versus a PLA-polymer SES at 12 months follow-up.

Detailed description

The BuMA stent (SINOMED, Beijing, China) was a novel biodegradable PLGA polymer sirolimus-eluting stent (SES), with design of adding an electro-grafting (eG) base layer between the polymer and the stainless steel stent strut.The eG layer can secure adhesion of the biodegradable PLGA coating as a result of the interdigitation, and the PLGA coating ensures 100% drug release within 30 days.The initial investigation showed a high strut coverage rate in both the BuMA stent and the Xience V stent at 3 months follow-up. Moreover, earlier vascular healing after drug-eluting stent implantation may reduce the incidence of stent thrombosis at follow-up and potentially shorten dual antiplatelet therapy duration. Therefore, we performed this randomized trial to investigate 12 months target lesion failure between the BuMA and the EXCEL stent, both with same eluted drug sirolimus, however different biodegradable polymer carriers.

Interventions

DEVICEBuMA

This group will contain 1175 subjects.

DEVICEEXCEL

This group will contain 1175 subjects.

Sponsors

Sino Medical Sciences Technology Inc.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* The patient must be ≥18 of age; * Symptomatic ischemic heart disease and/or objective evidence of myocardial ischemia including chronic stable coronary artery disease, or acute coronary syndrome including non-ST-elevation and ST-elevation myocardial infarction; * Acceptable candidate for CABG; * The patient is willing to comply with specified follow-up evaluations; * Patients who agree to accept the follow-up visits. * Patients can understand the study objectives psychologically and linguistically and show the sufficient compliance to the study protocol. Patients present acceptance of the risks and benefits described in the informed consent form. * At least one lesion with a diameter stenosis \>50% or more suitable for coronary stent implantation in a vessel with a reference diameter ranging from 2.5 mm to 4.0 mm;

Exclusion criteria

* Pregnant or nursing patients and those who plan pregnancy in the period up to 1 year following index procedure. * Patient has other medical illness (e.g., cancer, known malignancy, congestive heart failure, organ transplant recipient or candidate) or known history of substance abuse (alcohol, cocaine, heroin etc.) that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (i.e., less than 1 year); * Patient has a known hypersensitivity or contraindication to aspirin, heparin, clopidogrel/ticlopidine, stainless steel alloy, cobalt chromium, rapamycin , styrene-butylenes-styrene or poly-lactic acid (PLA) polymer, and/or contrast sensitivity that cannot be adequately pre-medicated; * Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study; * Currently participating in another investigational drug or device study or patient in inclusion in another investigational drug or device study during follow-up.

Design outcomes

Primary

MeasureTime frame
Target lesion failure (a composite of cardiac death, target lesion myocardial infarction and ischemia driven target lesionsrevascularization TLR) at 1 year12 months after PCI

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 13, 2026