Low Flow Anaesthesia, is There a Difference Between 2 Modern Anaesthetic Machines Using Different Gas Reservoir

Low Flow Anaesthesia; Cost-effectiveness of the Flow-I Anaesthesia Machine, a Comparison to Established Anaesthesia Delivery Unit

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02013869
Acronym
LF
Enrollment
40
Registered
2013-12-17
Start date
2015-05-31
Completion date
2017-08-31
Last updated
2024-03-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

General Anaesthesia

Keywords

fresh gas flow, quality of anaesthesia, minimal alveolar concentration

Brief summary

To study the Flow-I breathing circle during low flow general anaesthesia, whether this non-below system has advantages reduced time to reach Et 1MAC (minimal alveolar concentration) and lower consumption of inhaled agent

Detailed description

Assessing whether there are clinical differences in anaesthetic performance between standard anaesthesia workstation including a below and the new Flow-I device without a below

Interventions

DEVICEFlow-I, a modern anaesthetic machine without a bag/below/gas reservoir for compression of insufflation gas

Desflurane Dialed setting 18 % on the machine gas vaporized

DEVICEAsys, a anaesthetic machine with a bag/bellow for compression of gas to be insufflated

Desflurane dialed 18% on the machine gas vaporized

Sponsors

University of California, Irvine
CollaboratorOTHER
Jan Jakobsson
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
BASIC_SCIENCE
Masking
SINGLE (Investigator)

Intervention model description

We studied the time to reach a MAC value for two fifferent anaesthetic machines, Flow-i versus Aisys looking at the time to reach 1 MAC desflurane

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

ASA 1-2 patient 18 - 65 years scheduled for elective surgery

Exclusion criteria

ASA \> 2 heart failure COPD

Design outcomes

Primary

MeasureTime frameDescription
Time to reach 1.5 MAC (minimal alveolar concentration) Et1 hourThe time needed, seconds, to increase the end tidal desflurane concentration during wash-in from a 1 MAC to a 1.5 MAC with a constant fresh gas flow of 1 L/min and the vaporiser set a 3 MAC ( minimal alveolar concentration) (18%) will be compared between the two study groups

Secondary

MeasureTime frameDescription
amount of inhaled agent consumed ml/min5 hoursThe vaporiser will be weighed before and after each case and the amount of vapor, desflurane, consumed during the anaesthesia will be calculated Gr/min.
Postoperative Quality of Recovery72 hoursQuality of recovery will be followed during the first 72 hours after anaesthesia

Other

MeasureTime frameDescription
Adequate anaesthesia5 hoursPatients will be asked after end of anaesthesia if they have had any recall of intraoperative events

Countries

Sweden