Skip to content

Dynamic Preload Indicators in Sitting Position

Abilities of Dynamic Preload Dependence Indicators to Predict Fluid Responsiveness During Neurosurgery in Sitting Position

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02000570
Enrollment
31
Registered
2013-12-04
Start date
2013-10-17
Completion date
2018-01-11
Last updated
2018-09-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Neurosurgery in Sitting Position

Keywords

sitting position, PPV, SVV, PVI, fluid challenge, preload indicators

Brief summary

Intraoperative optimization of cardiac output using goal directed fluid challenge is associated with better outcome. Dynamic preload dependence indicators are well validated during surgery in supine position. Positioning from supine to sitting position under anesthesia is responsible of several hemodynamic changes. Predictability and cut-off values of dynamic preload dependence indicators during surgery in sitting position are unknown. The objective of this prospective study is to evaluate ability of three dynamic preload dependence indicators, i.e. PPV (Pulse Pressure Variation), SVV (Stroke Volume Variation) and PVI (Plethysmographic Variability Index), during neurosurgery in sitting position.

Detailed description

The primary objective is to determine PPV, SVV and PVI thresholds for which patients respond to fluid challenge in sitting position. The secondary objectives are to determine variations of PPV, SVV and PVI measures before and after positioning in sitting position, and to compare these values to each other.

Interventions

PROCEDURESitting position (neurosurgery)

Sponsors

Hospices Civils de Lyon
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* neurosurgery in sitting position * age \> 18

Exclusion criteria

* arrhythmias * severe heart failure * severe lung disease * contraindications to esophageal Doppler monitoring probe insertion (i.e. esophageal weakness) * renal failure

Design outcomes

Primary

MeasureTime frameDescription
PPV (Pulse pressure variation)3 minutes before and after fluid challenge in sitting positionPPV is derived from arterial pressure waveforms and is displayed in real -time on Intellivue MP70 Philips monitors. Value will be recorded before fluid challenge. Responders will be assessed by esophageal Doppler.
SVV (Stroke volume variation)3 minutes before and after positioning in sitting positionSVV is derived from arterial pressure waveforms and is displayed in real -time on Vigileo Edwards Lifesciences monitors. Value will be recorded before fluid challenge. Responders will be assessed by esophageal Doppler.
PVI (Plethysmographic variability index)3 minutes before and after positioning in sitting positionPVI is derived from plethysmography waveforms and is displayed in real-time on Radical 7 Masimo monitors. Value of each indicator will be recorded before fluid challenge. Responders will be assessed by esophageal Doppler.

Countries

France

Outcome results

None listed