Simple Technique to Improve Diagnostic Yield in EUS-FNA

Eliminating the Residual Negative Pressure in the EUS-FNA Needle Before Withdrawal Enhances the FNA Cytology Yield

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01995474
Enrollment
60
Registered
2013-11-26
Start date
2010-02-28
Completion date
2012-10-31
Last updated
2013-11-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lesion Sampled for Cytology

Keywords

EUS, pancreatic cancer, cytology, fine needle aspiration

Brief summary

Endoscopic ultrasound and fine needle aspiration are useful tools for the diagnosis and staging of pancreatic cancer. One potential limitation is contamination when needle traverses the gastrointestinal tract under continuous negative pressure. Gastrointestinal tract contamination can lead to misinterpretation of FNA specimens. We propose a technique to eliminate any remaining negative pressure during EUS-FNA and therefore decrease gastrointestinal tract contamination. Our hypothesis is that briefly untwisting the syringe from the biopsy channel after a specimen is obtained eliminates any remaining negative pressure in the FNA needle and therefore reduces GI tract contamination of EUS-FNA specimens, and will lead to improved diagnostic accuracy of this important clinical technique.

Detailed description

Endoscopic ultrasound (EUS) has evolved into a minimally invasive diagnostic and staging method. The addition of fine needle aspiration (FNA) increases the accuracy of EUS in the diagnosis and staging of pancreatic malignancies. An ultrasound probe attached to the end of the endoscope allows real-time direct visualization by means of ultrasound transmission. During the FNA process a needle is advanced through the biopsy channel of the endoscope and into the target lesion. In order to obtain a tissue specimen of a suspicious pancreatic lesion, an FNA needle must traverse either the stomach or duodenum to access the pancreatic mass. Once the needle has entered the target lesion a syringe is exchanged for the needle stylet and negative pressure is applied allowing acquisition of a cytology specimen. Negative pressure is released from the syringe and the stop cock is closed to the syringe. However, due to the relatively long length of the needle there is is significant remaining negative pressure at the needle tip. This leads to aspiration of surrounding material including GI mucosal contamination into the needle while removing it from the target lesion. Contamination of the FNA specimen from gastric or duodenal epithelium can occur with continued negative pressure at the needle tip upon withdrawal of the needle out of the target lesion. While EUS-FNA has a high specificity (96%), sensitivity (87%), and accuracy (94%), gastrointestinal tract contamination can lead to misinterpretation of FNA specimens. Based on clinical experience, we propose a technique to eliminate any remaining negative pressure during EUS-FNA and therefore decreasing gastrointestinal tract contamination.

Interventions

OTHERTwisted Syringe

briefly disconnecting the syringe from the biopsy channel after a specimen is obtained and then reconnecting it

syringe is exchanged for the needle stylet and negative pressure is applied allowing acquisition of a cytology specimen.

Sponsors

Medical College of Wisconsin
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age \> 18 * Not pregnant * Can give consent * Patients with suspicious GI lesions in need of tissue diagnosis by means of EUS/FNA

Exclusion criteria

* Pregnant * Age \< 18 * Cannot give consent * EUS not technically possible

Design outcomes

Primary

MeasureTime frameDescription
Efficacy of FNA biopsy1 weekThe efficacy of fine needle aspiration is assessed using on site cytopathologists who are blinded with respect to the study ARM. The efficacy of diagnostic yield from samples obtained using the needle-off technique is directly compared to the diagnostic yield of samples obtained using conventional technique.