Skip to content

Efficacy of EVP 1001-1 (SeeMore) in the Assessment of Myocardial Viability in Patients With Cardiovascular Disease

Efficacy of EVP 1001-1 (SeeMore) in the Assessment of Myocardial Viability in Patients With Cardiovascular Disease

Status
Completed
Phases
Phase 1Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01989195
Enrollment
6
Registered
2013-11-20
Start date
2013-05-31
Completion date
2013-06-30
Last updated
2017-01-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

ISCHEMIC CARDIOMYOPATHY

Keywords

ISCHEMIC OR CORONARY HEART DISEASE, MYOCARDIAL INFARCTION, MAGNETIC RESONANCE IMAGING, DELAYED GADOLINIUM ENHANCEMENT MRI, MANGANESE-ENHANCED MRI, INFARCT VOLUME/SIZE, ALL CAUSE MORTALITY, VENTRICULAR ARRHYTHMIAS

Brief summary

The investigator hopes to introduce a novel MRI contrast agent with SeeMore ™ that directly defines viable myocardium. Identifying viable myocardium non-invasively using cardiac MRI is still a moving target and a question we plan to answer more definitively with the SeeMore ™ contrast. Though well tested in small and large animals and Phase I & II clinical trials, the investigators would like to determine the efficacy of the SeeMore contrast further in a clinical setting. SeeMore is a new manganese (Mn)-based intravenous imaging agent being developed to enhance magnetic resonance imaging (MRI). While Mn has long been known to have desirable magnetic and kinetic properties for MRI, use in humans was not initially possible due to cardiovascular depression and electrocardiogram (ECG) changes, including prolongation of PR and QTc intervals, associated with intravenous administration \[1-5\]. SeeMore provides Mn in a form that maintains the desired magnetic and kinetic properties while overcoming the cardiovascular toxicity of Mn. SeeMore is taken up into heart cells (primarily via addition of calcium to avoid cardiotoxic effects; please refer to US patent #5,980,863). The potential to distinguish healthy heart tissue from unhealthy heart tissue based on a specific sustained pattern of enhancement provides a basis for evaluating the performance of SeeMore in heart patients. It may be possible to enhance the utility of MRI for heart disease through the use of an imaging agent that is specifically taken up into heart cells. SeeMore is the only cardiac-specific agent being developed for this purpose. Unlike nuclear perfusion agents, SeeMore is not radioactive and does not require special handling, shielding, transport or storage. In addition, the specific pattern of enhancement achieved in the heart muscle persists over time, offering potential benefits over the nonspecific extracellular agents currently available for MRI or X-ray/CT procedures. This feature allows full use of the high resolution of MRI, since there is not a trade-off of high spatial resolution for temporal (first-pass) resolution. It is anticipated the features offered by SeeMore along with the high resolution, three dimensional attributes of MRI will result in higher accuracy than is available with other current modalities in practice, including stress echocardiograms, cardiac MRI using gadolinium contrast and nuclear studies such as SPECT and PET. This will be evaluated in this study and serve as the basis for pivotal registration studies. All components of SeeMore™ are USP and are approved for use as drugs in man, orally and/or intravenously.

Detailed description

This is an open-label, baseline-controlled study. An initial cohort study of patients to conduct safety evaluation will be conducted before proceeding with the additional patients. In this initial cohort, a patient will be dosed based on the Phase 1 and 2 clinical trial data evaluation completed by Eagle Vision Pharmaceutical, Inc. Starting 30 minutes before the cardiac MRI scan (CMR), the subjects will take a 4 mg tablet of ondansetron by mouth. CMR will subsequently take place and SeeMore™ will then be administered approximately 15 minutes into the scan for contrast enhanced images. SeeMore™ will be administered intravenously over approximately one minute. The subjects will each receive 0.28 mL/kg of SeeMore™. All subjects will be monitored closely from before ondansetron administration until their discharge from the imaging center. If positive delayed-enhanced MRI is detected, the subject will undergo MEMRI within 1 week. The investigators plan to perform imaging with CMR and SeeMore™ within a week after standard gadolinium-based delayed enhanced imaging by CMR (performed as clinically indicated within Stanford Hospital by the patient's physician) to directly compare the two different contrast enhanced images (SeeMore vs Gadolinium in determining viable myocardium). Parameters to be Measured: A standard physical examination will be performed within 24 hours prior to dosing and at the end of experimental MEMRI imaging (approximately 1 hour post dosing). A standard 12-lead EKG will be performed both before the experimental MR study and after the experimental MR study to assure no significant EKG changes have occurred. HR will be measured before and after the study. After the study, the patient will have another standard 12-lead EKG performed to compare with the pre-MRI 12-lead EKG. The patient's symptoms will be reassessed 1 hour and 1 year after infusion of the SeeMore contrast. Adverse events (AEs) and discomforts will be recorded until discharge from the imaging center. Any clinically relevant changes from baseline in vital signs, ECG rhythm, clinical chemistries or physical condition and all AEs will be followed until resolution or until the outcome is known. Primary efficacy will be based on determining whether the heart is normal or abnormal and if abnormal whether there is an infarction, ischemia or both. This provides the basis for calculating sensitivity, specificity, accuracy and predictive values. In addition, the location, size, conspicuity and associated confidence for any disease will be recorded. The study will be stopped for any significant adverse cardiovascular event including cardiovascular death, myocardial infarction, ventricular arrhythmia, ICD firing, congestive heart failure, hospitalization, or syncope.

Interventions

DRUG'SEEMORE' - MANGANESE-ENHANCED MRI CONTRAST REAGENT

EACH SUBJECT UNDERWENT 2 CARDIAC MRI PROCEDURES: ONE WITH MAGNEVIST (GADOLINIUM), ONE WITH SEEMORE (MANGANESE) REAGENT * CARDIAC MRI USING STANDARD DOSE OF 0.2mMOL/KG MAGNEVIST IV (IN THE VEIN) * CARDIAC MRI USING SEEMORE REAGENT, DOSE: 0.35CC/KG IV (IN THE VEIN) 1 WEEK AFTER GADOLINIUM MRI

Sponsors

Stanford University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

\- All subjects to be entered must: * be at least 18 years of age. * if female, be nonpregnant as evidenced by a serum pregnancy test and using a medically-approved method of birth control, or post-menopausal or surgically sterile * provide written informed consent after having received oral and written information about the study * be in stable health based on medical history, examination and tests

Exclusion criteria

\- have a positive pregnancy test (females) * received an investigational drug or device within 30 days prior to administration of SeeMore? * have known hypersensitivity to ondansetron or other selective serotonin 5HT3 receptor blockers * have a history of drug abuse or alcoholism * are taking a digitalis preparation or calcium channel blocker * have a history of torsades or prolonged QT/QTc interval * have NYHA Grade IV heart failure * have abnormal liver function tests or a history of liver disease * have uncontrolled hypertension (Systolic Blood Pressure \> 140 or Diastolic BP \> 90 consistently at baseline) * have abnormal baseline potassium or calcium values or hemoglobin less than 10 g/dl * are noncompliant or otherwise unlikely to perform as required by the protocol * have pretest likelihood of CAD for which the requisite number of subjects have been entered * develop an arrhythmia prior to or during either of the exercise tests; SeeMore? should not be administered.

Design outcomes

Primary

MeasureTime frameDescription
COMPARISON OF MYOCARDIAL INFARCTION SIZE MEASUREMENTS USING INVESTIGATIONAL MANGANESE-ENHANCED MRI (MEMRI) OR DELAYED GADOLINIUM ENHANCED MRI (DEMRI)Day 1 (1 MRI)Measured as percentage of myocardial injury volume to the total left ventricular myocardial volume

Secondary

MeasureTime frameDescription
SAFETY AND TOLERABILITY OF MANGANESE CONTRAST REAGENTPre MRI and Post MRI on same day (Day 1)QRS Duration: SUBJECTS UNDERWENT PRE- AND POST-MRI EKG TESTING TO ASSESS ANY ADVERSE SYMPTOMS OR SIGNS. THE POST EKG WAS PERFORMED AFTER MEMRI SCAN WERE COMPLETE. EKG WAS NOT OBTAINED BEFORE AND AFTER DEMRI. Measured the difference in heart rate per EKG before and after MEMRI study.
Significant Cardiovascular Event1 yearHospitalization and procedures for chest pain, arrhythmias, and all-cause mortality
Heart Rate: SAFETY AND TOLERABILITY OF MANGANESE CONTRAST REAGENTPre MRI and Post MRI on same day (Day 1)SUBJECTS UNDERWENT PRE- AND POST-MRI EKG TESTING TO ASSESS ANY ADVERSE SYMPTOMS OR SIGNS. THE POST EKG WAS PERFORMED AFTER MEMRI SCAN WERE COMPLETE. EKG WAS NOT OBTAINED BEFORE AND AFTER DEMRI. Measured the difference in heart rate per EKG before and after MEMRI study.

Countries

United States

Participant flow

Participants by arm

ArmCount
CORONARY DISEASE SUBJECT
ALL SUBJECTS IN THIS STUDY HAVE PREVIOUSLY DOCUMENTED CORONARY ARTERY DISEASE BY ANGIOGRAPHY 'SEEMORE' - MANGANESE-ENHANCED MRI CONTRAST REAGENT: EACH SUBJECT UNDERWENT 2 CARDIAC MRI PROCEDURES: ONE WITH MAGNEVIST (GADOLINIUM), ONE WITH SEEMORE (MANGANESE) REAGENT * CARDIAC MRI USING STANDARD DOSE OF 0.2mMOL/KG MAGNEVIST IV (IN THE VEIN) * CARDIAC MRI USING SEEMORE REAGENT, DOSE: 0.35CC/KG IV (IN THE VEIN) 1 WEEK AFTER GADOLINIUM MRI
6
Total6

Baseline characteristics

CharacteristicCORONARY DISEASE SUBJECT
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
0 Participants
Age, Categorical
Between 18 and 65 years
6 Participants
Gender
Female
0 Participants
Gender
Male
6 Participants
Region of Enrollment
United States
6 participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
— / —
other
Total, other adverse events
1 / 6
serious
Total, serious adverse events
0 / 6

Outcome results

Primary

COMPARISON OF MYOCARDIAL INFARCTION SIZE MEASUREMENTS USING INVESTIGATIONAL MANGANESE-ENHANCED MRI (MEMRI) OR DELAYED GADOLINIUM ENHANCED MRI (DEMRI)

Measured as percentage of myocardial injury volume to the total left ventricular myocardial volume

Time frame: Day 1 (1 MRI)

ArmMeasureValue (MEAN)Dispersion
DEMRI CORONARY DISEASE SUBJECTCOMPARISON OF MYOCARDIAL INFARCTION SIZE MEASUREMENTS USING INVESTIGATIONAL MANGANESE-ENHANCED MRI (MEMRI) OR DELAYED GADOLINIUM ENHANCED MRI (DEMRI)41 percentage of infarct to Left VentricleStandard Deviation 11.4
INVESTIGATIONAL MANGANESE-ENHANCED MRI (MEMRI)COMPARISON OF MYOCARDIAL INFARCTION SIZE MEASUREMENTS USING INVESTIGATIONAL MANGANESE-ENHANCED MRI (MEMRI) OR DELAYED GADOLINIUM ENHANCED MRI (DEMRI)18.25 percentage of infarct to Left VentricleStandard Deviation 1.7
p-value: <0.05t-test, 2 sided
Secondary

Heart Rate: SAFETY AND TOLERABILITY OF MANGANESE CONTRAST REAGENT

SUBJECTS UNDERWENT PRE- AND POST-MRI EKG TESTING TO ASSESS ANY ADVERSE SYMPTOMS OR SIGNS. THE POST EKG WAS PERFORMED AFTER MEMRI SCAN WERE COMPLETE. EKG WAS NOT OBTAINED BEFORE AND AFTER DEMRI. Measured the difference in heart rate per EKG before and after MEMRI study.

Time frame: Pre MRI and Post MRI on same day (Day 1)

ArmMeasureValue (MEAN)Dispersion
DEMRI CORONARY DISEASE SUBJECTHeart Rate: SAFETY AND TOLERABILITY OF MANGANESE CONTRAST REAGENT7.83 Heart Rate change in beats per minuteStandard Deviation 3.54
Secondary

SAFETY AND TOLERABILITY OF MANGANESE CONTRAST REAGENT

QRS Duration: SUBJECTS UNDERWENT PRE- AND POST-MRI EKG TESTING TO ASSESS ANY ADVERSE SYMPTOMS OR SIGNS. THE POST EKG WAS PERFORMED AFTER MEMRI SCAN WERE COMPLETE. EKG WAS NOT OBTAINED BEFORE AND AFTER DEMRI. Measured the difference in heart rate per EKG before and after MEMRI study.

Time frame: Pre MRI and Post MRI on same day (Day 1)

ArmMeasureValue (MEAN)Dispersion
DEMRI CORONARY DISEASE SUBJECTSAFETY AND TOLERABILITY OF MANGANESE CONTRAST REAGENT10 Change in QRS Duration in millisecondsStandard Deviation 8.12
Secondary

Significant Cardiovascular Event

Hospitalization and procedures for chest pain, arrhythmias, and all-cause mortality

Time frame: 1 year

ArmMeasureValue (NUMBER)
DEMRI CORONARY DISEASE SUBJECTSignificant Cardiovascular Event0 participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026