Imaging Based Dosimetry for Individualized Internal Emitter Therapy

Imaging Based Dosimetry for Individualized Internal Emitter Therapy

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01988272
Enrollment
33
Registered
2013-11-20
Start date
2011-06-30
Completion date
2016-01-31
Last updated
2016-05-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Non-Hodgkin's Lymphoma

Keywords

SPECT/CT, Dosimetry, Radiation absorbed dose, Non-Hodgkin's Lymphoma, I-131 tositumomab radioimmunotherapy

Brief summary

The goal of this study is to develop imaging based methods to accurately determine the energy absorbed (absorbed dose) by tumor tissue and bone marrow after radioimmunotherapy with I-131 tositumomab . The administration of the radioactive, iodine-131 labeled, monoclonal antibody I-131 tositumomab, (also known as Bexxar) is part of the patient's clinical treatment protocol. For the absorbed dose measurement, investigators at the University of Michigan are evaluating a new Nuclear Medicine SPECT/CT imaging system . This new camera combines a CT imaging system in addition to a Nuclear Medicine SPECT scanner. CT scans allow the doctors to see a high quality picture of your internal organs. The Nuclear Medicine SPECT scanner allows the doctors to see the uptake of the radioactive I-131 including the tumor sites. The improved imaging using the SPECT/CT enables more accurate calculation of the energy absorbed by tumor tissue and bone marrow. Using the results from these calculations and clinical follow up data, the researchers will investigate the relationship between the absorbed dose to the tumor and the patient's tumor response as well as the relationship between the absorbed dose to the bone marrow and the bone marrow toxicity. These relationships can potentially be used in the future by doctors to help determine how much radioactive I-131 to administer to each patient to get optimal results.

Interventions

Patients will undergo scanning on the above system.

Sponsors

National Institutes of Health (NIH)
CollaboratorNIH
University of Michigan
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

* • Clinically stable patients undergoing I-131 Tositumomab (Bexxar) for treatment of Non-Hodgkin Lymphomas

Exclusion criteria

* • Clinical instability * Patients who are unable to lie flat on the imaging systems long enough to permit imaging protocols to be performed * Refusal to provide informed consent * Patients who are pregnant

Design outcomes

Primary

MeasureTime frameDescription
Correlation between radiation absorbed dose to tumor and response or progression free survival6 monthsTumor absorbed doses will be calculated based on research SPECT/CT imaging and correlated with the response as assessed by clinical PET/CT.

Secondary

MeasureTime frameDescription
Assess correlation between radiation absorbed dose to the bone marrow and hematologic toxicity.6 monthsAbsorbed dose will be determined by SPECT/CT imaging of the marrow rich lumbar region and will be correlated with toxicity based on follow-up blood counts.

Countries

United States

Outcome results

None listed