Skip to content

RETeval Study for Diabetic Retinopathy

RETeval Calibration / Validation Study - Diabetic Retinopathy

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01950663
Enrollment
468
Registered
2013-09-25
Start date
2013-09-30
Completion date
2014-04-30
Last updated
2017-06-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetic Retinopathy

Keywords

Diagnostic Equipment, Validation Studies

Brief summary

RETeval is a new handheld device intended to detect vision threatening diabetic retinopathy. The purpose of this study is to calibrate RETeval, and then measure its ability to detect vision threatening diabetic retinopathy. Early Treatment Diabetic Retinopathy Study (ETDRS) 7-field, dilated, stereo, color fundus photography, read according to the ETDRS protocol, will be used as the gold standard.

Detailed description

Diabetic retinopathy is the leading cause of preventable blindness in working age Americans. The associated loss of quality of life, and the economic loss from health care costs and lost productivity, are staggering. This burden is increasing rapidly as the epidemic of diabetes continues. In the developing world, diabetic retinopathy is expected to become the leading cause of preventable blindness since the prevalence of diabetes correlates closely with the dietary changes, obesity, and sedentary lifestyles that accompany economic development. Half of all people with proliferative diabetic retinopathy will be blind within five years. With proven laser and intravitreal drug therapy this risk is reduced to less than 5%, a ten-fold decrease in risk. One third of all people with diabetic macular edema will suffer moderate visual loss in three years. With proven therapy this risk is reduced to less than 10%, a three-fold decrease in risk. Nonetheless, diabetic retinopathy remains the leading cause of preventable blindness in working age Americans. Excellent diabetes control prevents or significantly reduces the development and progression of diabetic retinopathy but this approach requires difficult lifestyle changes. Therefore, timely identification of patients at risk for blindness, and assuring they receive proven care, are essential to eliminate blindness from diabetic retinopathy. Unfortunately, despite decades of public health awareness campaigns and programs, only 56.9% of US patients with diabetes received universally recommended eye evaluations in 2011. One reason for this failure is the complexity of existing methods for diabetic retinopathy testing. To be effective, accurate testing should be available in the primary care physician's office since the need for an additional visit to an ophthalmologist is another reason universal testing has failed. To succeed in the primary care physician's office, existing personnel, with minimal training, must be able to accurately and easily test patients. The testing method must take little time and require no additional space since efficient time and space utilization are critical in primary care settings. It must meet quality measures used by Medicare and other payors to award financial incentives. Finally, it must be reimbursed at a favorable level. RETeval is LKC Technologies' new, handheld, non-invasive, device that measures full-field electroretinogram (ERG) cone b-wave photopic flicker implicit times quickly and easily in a primary care setting. RETeval is simple to use and takes less than five minutes for most patients. It is a handheld device that requires no additional space. Based on published literature, the implicit time is significantly delayed in eyes with severe non proliferative diabetic retinopathy (NPDR) and proliferative diabetic retinopathy (PDR) relative to eyes with milder forms of DR. These findings suggest that the photopic ERG implicit time can be a good indicator for the objective evaluation of the severity of DR ranging from mild NPDR to PDR. This study will measure the accuracy of the RETeval device. ETDRS 7-field, dilated, stereo, color fundus photography, read according to the ETDRS protocol, will be used as the gold standard. Cone b-wave photopic flicker implicit time, measured by the RETeval device, and ETDRS photography, will be performed during a single visit. A random sample of the results, the calibration set, will be used to calibrate the referral threshold for the RETeval device. The remaining results, the validation set, will be used as an independent validation to assess accuracy. If RETeval is accurate, and is accepted as a quality measure meeting performance standards, it will be an ideal method to test for retinopathy in patients with diabetes.

Interventions

DEVICERETeval

RETeval is a new handheld device intended to detect vision threatening diabetic retinopathy by measuring the response of the retina to a flash of light.

Sponsors

LKC Technologies, Inc.
CollaboratorINDUSTRY
National Eye Institute (NEI)
CollaboratorNIH
Inoveon Corporation
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients diagnosed with diabetes and treated with at least one oral hypoglycemic medication or insulin * Eighteen years or older

Exclusion criteria

* History of photosensitive epilepsy * Previous laser or drug treatment for diabetic retinopathy or macular edema * Eye diseases other than diabetic retinopathy or macular edema that, in the opinion of the recruiting ophthalmologist, may affect the electroretinogram or result in ungradable Early Treatment Diabetic Retinopathy Study Protocol images. * Inability or unwillingness of the subject or legal guardian/representative to give written informed consent

Design outcomes

Primary

MeasureTime frameDescription
Per Patient Referral AccuracyDuring a single visit, implicit time, measured by the RETeval device, and ETDRS photography, will be performed to support the analysis of the accuracy of the RETeval device.Accuracy will be reported as count of participants with referral status correctly identified, sensitivity, and specificity, with ETDRS photography and reading as the gold standard.

Countries

United States

Participant flow

Participants by arm

ArmCount
RETeval
RETeval is a new handheld device intended to detect vision threatening diabetic retinopathy by measuring the response of the retina to a flash of light. RETeval: RETeval is a new handheld device intended to detect vision threatening diabetic retinopathy by measuring the response of the retina to a flash of light.
467
Total467

Baseline characteristics

CharacteristicRETeval
Age, Continuous61 years
STANDARD_DEVIATION 11
Ethnicity (NIH/OMB)
Hispanic or Latino
9 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
458 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
24 Participants
Race (NIH/OMB)
Asian
2 Participants
Race (NIH/OMB)
Black or African American
184 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
14 Participants
Race (NIH/OMB)
White
243 Participants
Region of Enrollment
United States
467 participants
Sex: Female, Male
Female
58 Participants
Sex: Female, Male
Male
409 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 468
other
Total, other adverse events
0 / 468
serious
Total, serious adverse events
0 / 468

Outcome results

Primary

Per Patient Referral Accuracy

Accuracy will be reported as count of participants with referral status correctly identified, sensitivity, and specificity, with ETDRS photography and reading as the gold standard.

Time frame: During a single visit, implicit time, measured by the RETeval device, and ETDRS photography, will be performed to support the analysis of the accuracy of the RETeval device.

Population: Participants with gradeable fundus photos and RETeval measurements

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
RETevalPer Patient Referral Accuracy318 Participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026