Safety and Efficacy Evaluation of a New Contact Lens Disinfecting Solution in Soft Contact Lens Wearers

Clinical Evaluation of the Safety and Efficacy of FID 120947A Compared to a Marketed Lens Care Solution

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01912768
Enrollment
362
Registered
2013-07-31
Start date
2013-12-31
Completion date
2014-05-31
Last updated
2015-07-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Myopia, Astigmatism, Hyperopia, Refractive Error

Keywords

contact lenses, contact lens solution, soft contact lenses

Brief summary

The purpose of this study is demonstrate substantial equivalence of an investigational contact lens disinfecting solution to a commercially available contact lens solution in silicone hydrogel and soft contact lens wearers.

Detailed description

Subjects with normal eyes (other than correction for refractive error) successfully wearing soft contact lenses were randomized 2:1 to receive either the investigational or commercial contact lens solution for daily use throughout the study (90 days).

Interventions

Investigational 3% hydrogen peroxide solution intended for simultaneous cleaning, protein removal, disinfecting and storage of silicone hydrogel and soft contact lenses

DEVICErenu fresh multi-purpose solution

Commercially available solution indicated for cleaning, removing protein deposits, rinsing, chemical disinfection, and storage of soft contact lenses

Commercially available soft contact lenses worn a minimum of 8 hours each day on a daily wear basis for the duration of the study (90 days). A fresh pair will be dispensed on Day 0, Day 30, and Day 60.

Sponsors

Alcon Research
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Normal eyes (other than correction for visual acuity); * Successful history of silicone hydrogel or soft contact lens wear in both eyes in one of the following brands: Soflens® 38, Proclear DW, Frequency 55, Acuvue® Oasys™, Air Optix Aqua, O2 OPTIX, Air Optix for Astigmatism, Air Optix Aqua Multifocal, Biofinity®, PureVision®, PureVision®2; * Best spectacle corrected distance visual acuity greater than or equal to 20/25 in each eye; * Other protocol-defined inclusion criteria may apply.

Exclusion criteria

* Any ocular or systemic medical condition that may, in the opinion of the investigator, preclude safe administration of the investigational products or affect the results of this study; * Need to wear contact lenses on an extended wear basis (ie, overnight) during the study; * Use of a daily cleaner and/or an enzyme cleaner to care for lenses at least 7 days prior to Visit 1; * History of intolerance or hypersensitivity to any component of the investigational products; * Use of all over-the-counter (OTC) or prescribed topical ocular medications within 7 days prior to Visit 1; * Moderate, severe, abnormal, or other ocular findings; * Current or history of ocular infection, severe inflammation, or disease within 6 months prior to Visit 1; * Any systemic disease at Visit 1 (including allergies, respiratory infections or colds) that may affect the eye or be exacerbated by use of contact lenses or contact lens solutions; * Use of systemic medications that may contribute to adverse ocular effects unless on a stable dosing regimen; * Ocular surgery within the last 12 months; * Other protocol-defined

Design outcomes

Primary

MeasureTime frameDescription
Percentage of Subjects With Visibly Clean LensesDay 7, Day 30, Day 60, Day 90Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered. A lens was considered visibly clean if it had nondetectable films or deposits. One eye (study eye) contributed to the analysis.
Percentage of Subjects With Crystalline Deposits by TypeDay 7, Day 30, Day 60, Day 90Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered: Type II = films or deposits visible only under special conditions, such as special illumination using an eyepiece of 7-10 times magnification, Type III = films or deposits readily visible on a dry lens under room lighting, with unaided eye, and Type IV = films or deposits obvious under room lighting, with unaided eye, when the lens is wet or dry. One eye (study eye) contributed to the analysis.
Percentage of Subjects With Film Deposits by TypeDay 7, Day 30, Day 60, Day 90Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered: Type II = films or deposits visible only under special conditions, such as special illumination using an eyepiece of 7-10 times magnification, Type III = films or deposits readily visible on a dry lens under room lighting, with unaided eye, and Type IV = films or deposits obvious under room lighting, with unaided eye, when the lens is wet or dry. One eye (study eye) contributed to the analysis.
Average Residual Lens LysozymeDay 30/Early ExitWorn study lenses were removed and analyzed by high performance liquid chromatography (HPLC) for residual lens lysozyme (protein). Values reported as lower than the limit of quantitation or none detected were imputed as 0.5 μg or 0 μg, respectively. A lower value indicates less lysozyme deposition. One eye (study eye) contributed to the analysis.
Percentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeBaseline (Day 0), Day 7, Day 30, Day 60, Day 90Distance VA was assessed for each eye individually while reading a chart distant to the participant in dimmed room illumination. VA was measured using a Snellen chart, with 20/20 Snellen acuity considered normal distance-eyesight. A line increase indicates an improvement in VA. One eye (study eye) contributed to the analysis.
Average Lens Wear TimeDay 7, Day 30, Day 60, Day 90Subject recorded a response to the question, Averaging over the last 3 days, how many hours per day did you wear your contact lenses? Lens wear time was measured in hours.
Number of Unscheduled Lens Replacements by ReasonUp to Day 90A fresh pair of lenses was dispensed on Day 0, Day 30, and Day 60. Lenses replaced at other times were considered unscheduled. The counts in the table represent the total number of unscheduled lenses replaced by reason for any eye, any subject.
Likert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Day 30, Day 60, Day 90Lens comfort was assessed by the subject as a single response on a 5-point Likert scale (Strongly Agree, Agree, Undecided, Disagree, Strongly Disagree) to best describe their lens wearing experience over the last 3 days. Responses were summarized by agreement category and presented as percentage of subjects.
Likert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Day 30, Day 60, Day 90Clear vision was assessed by the subject as a single response on a 5-point Likert scale (Strongly Agree, Agree, Undecided, Disagree, Strongly Disagree) to best describe their lens wearing experience over the last 3 days. Responses were summarized by agreement category and presented as percentage of subjects.
Likert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Day 30, Day 60, Day 90Product handling was assessed by the subject as a single response on a 5-point Likert scale (Strongly Agree, Agree, Undecided, Disagree, Strongly Disagree) to best describe their lens wearing experience over the last 3 days. Responses were summarized by agreement category and presented as percentage of subjects.
Crystalline Deposit Area CoveredDay 7, Day 30, Day 60, Day 90Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered. Values were reported as a percentage of lens area covered. One eye (study eye) contributed to the analysis.
Film Deposit Area CoveredDay 7, Day 30, Day 60, Day 90Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered. Values were reported as a percentage of lens area covered. One eye (study eye) contributed to the analysis.

Participant flow

Recruitment details

Subjects were recruited from 17 study centers located in the US.

Pre-assignment details

Of the 362 enrolled, 10 subjects were exited as screen failures prior to randomization. This reporting group includes all randomized subjects (352).

Participants by arm

ArmCount
FID 120947A
Contact lens disinfecting solution used with soft contact lenses (study lenses) on a daily basis for 90 days
239
Renu Fresh
Multi-purpose solution used with soft contact lenses (study lenses) on a daily basis for 90 days
113
Total352

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudyAdverse Event20
Overall StudyLost to Follow-up21
Overall StudyRandomized in error10
Overall StudyWithdrawal by Subject53

Baseline characteristics

CharacteristicFID 120947ARenu FreshTotal
Age, Continuous34.5 years
STANDARD_DEVIATION 11.7
35.3 years
STANDARD_DEVIATION 10.9
34.8 years
STANDARD_DEVIATION 11.5
Sex: Female, Male
Female
174 Participants92 Participants266 Participants
Sex: Female, Male
Male
65 Participants21 Participants86 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
EG002
affected / at risk
deaths
Total, all-cause mortality
— / —— / —— / —
other
Total, other adverse events
0 / 3620 / 2380 / 113
serious
Total, serious adverse events
0 / 3621 / 2380 / 113

Outcome results

Primary

Average Lens Wear Time

Subject recorded a response to the question, Averaging over the last 3 days, how many hours per day did you wear your contact lenses? Lens wear time was measured in hours.

Time frame: Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with data in each treatment group, respectively, by visit.

ArmMeasureGroupValue (MEAN)Dispersion
FID 120947AAverage Lens Wear TimeDay 30, n=234, 11212.9 HoursStandard Deviation 2.7
FID 120947AAverage Lens Wear TimeDay 90, n=229, 10913.1 HoursStandard Deviation 2.7
FID 120947AAverage Lens Wear TimeDay 60, n=232, 11013.0 HoursStandard Deviation 2.6
FID 120947AAverage Lens Wear TimeDay 7, n=236, 11312.9 HoursStandard Deviation 2.6
Renu FreshAverage Lens Wear TimeDay 60, n=232, 11012.6 HoursStandard Deviation 2.6
Renu FreshAverage Lens Wear TimeDay 30, n=234, 11212.6 HoursStandard Deviation 2.6
Renu FreshAverage Lens Wear TimeDay 7, n=236, 11312.6 HoursStandard Deviation 2.6
Renu FreshAverage Lens Wear TimeDay 90, n=229, 10912.9 HoursStandard Deviation 2.7
Primary

Average Residual Lens Lysozyme

Worn study lenses were removed and analyzed by high performance liquid chromatography (HPLC) for residual lens lysozyme (protein). Values reported as lower than the limit of quantitation or none detected were imputed as 0.5 μg or 0 μg, respectively. A lower value indicates less lysozyme deposition. One eye (study eye) contributed to the analysis.

Time frame: Day 30/Early Exit

Population: This analysis population includes all subjects with data at visit.

ArmMeasureValue (MEAN)Dispersion
FID 120947AAverage Residual Lens Lysozyme70.2 micrograms per lensStandard Deviation 192.1
Renu FreshAverage Residual Lens Lysozyme114.5 micrograms per lensStandard Deviation 295.5
Primary

Crystalline Deposit Area Covered

Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered. Values were reported as a percentage of lens area covered. One eye (study eye) contributed to the analysis.

Time frame: Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with crystalline deposits in each treatment group, respectively, by visit.

ArmMeasureGroupValue (MEAN)Dispersion
FID 120947ACrystalline Deposit Area CoveredDay 7, n=55, 3212.5 percentage of lens areaStandard Deviation 12.2
FID 120947ACrystalline Deposit Area CoveredDay 30, n=74, 3712.1 percentage of lens areaStandard Deviation 9.8
FID 120947ACrystalline Deposit Area CoveredDay 60, n=73, 3613.0 percentage of lens areaStandard Deviation 10.2
FID 120947ACrystalline Deposit Area CoveredDay 90, n=69, 4212.2 percentage of lens areaStandard Deviation 10.9
Renu FreshCrystalline Deposit Area CoveredDay 90, n=69, 4214.0 percentage of lens areaStandard Deviation 15.1
Renu FreshCrystalline Deposit Area CoveredDay 7, n=55, 3217.8 percentage of lens areaStandard Deviation 18.5
Renu FreshCrystalline Deposit Area CoveredDay 60, n=73, 3613.3 percentage of lens areaStandard Deviation 10.2
Renu FreshCrystalline Deposit Area CoveredDay 30, n=74, 3714.0 percentage of lens areaStandard Deviation 16.8
Primary

Film Deposit Area Covered

Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered. Values were reported as a percentage of lens area covered. One eye (study eye) contributed to the analysis.

Time frame: Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with film deposits in each treatment group, respectively, by visit.

ArmMeasureGroupValue (MEAN)Dispersion
FID 120947AFilm Deposit Area CoveredDay 7, n=114, 5618.7 percentage of lens areaStandard Deviation 12.2
FID 120947AFilm Deposit Area CoveredDay 30, n=125, 6618.9 percentage of lens areaStandard Deviation 14.3
FID 120947AFilm Deposit Area CoveredDay 60, n=114, 6321.0 percentage of lens areaStandard Deviation 16.1
FID 120947AFilm Deposit Area CoveredDay 90, n=114, 5917.3 percentage of lens areaStandard Deviation 12.8
Renu FreshFilm Deposit Area CoveredDay 90, n=114, 5920.9 percentage of lens areaStandard Deviation 14.6
Renu FreshFilm Deposit Area CoveredDay 7, n=114, 5616.7 percentage of lens areaStandard Deviation 12.1
Renu FreshFilm Deposit Area CoveredDay 60, n=114, 6323.4 percentage of lens areaStandard Deviation 15.3
Renu FreshFilm Deposit Area CoveredDay 30, n=125, 6620.5 percentage of lens areaStandard Deviation 14.4
Primary

Likert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.

Clear vision was assessed by the subject as a single response on a 5-point Likert scale (Strongly Agree, Agree, Undecided, Disagree, Strongly Disagree) to best describe their lens wearing experience over the last 3 days. Responses were summarized by agreement category and presented as percentage of subjects.

Time frame: Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with data in each treatment group, respectively, by visit.

ArmMeasureGroupValue (NUMBER)
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Strongly Agree, n=236, 11330.5 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Agree, n=236, 11357.2 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Undecided, n=236, 1136.4 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Disagree, n=236, 1135.5 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Strongly Disagree, n=236, 1130.4 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Strongly Agree, n=234, 11227.4 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Agree, n=234, 11253.8 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Undecided, n=234, 1125.1 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Disagree, n=234, 11212.4 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Strongly Disagree, n=234, 1121.3 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Strongly Agree, n=232, 11020.3 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Agree, n=232, 11062.1 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Undecided, n=232, 1105.2 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Disagree, n=232, 11012.1 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Strongly Disagree, n=232, 1100.4 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Strongly Agree, n=229, 10924.5 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Agree, n=229, 10959.4 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Undecided, n=229, 1096.6 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Disagree, n=229, 1099.2 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Strongly Disagree, n=229, 1090.4 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Undecided, n=229, 1097.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Strongly Agree, n=236, 11329.2 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Strongly Agree, n=232, 11017.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Agree, n=236, 11359.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Strongly Agree, n=229, 10917.4 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Undecided, n=236, 1136.2 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Agree, n=232, 11061.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Disagree, n=236, 1134.4 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Strongly Disagree, n=229, 1093.7 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 7, Strongly Disagree, n=236, 1130.9 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Undecided, n=232, 1106.4 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Strongly Agree, n=234, 11220.5 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Agree, n=229, 10963.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Agree, n=234, 11259.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Disagree, n=232, 11011.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Undecided, n=234, 1127.1 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 90, Disagree, n=229, 1098.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Disagree, n=234, 1129.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 60, Strongly Disagree, n=232, 1102.7 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, at the End of the Lens Wearing Day my Vision is Clear.Day 30, Strongly Disagree, n=234, 1122.7 percentage of subjects
Primary

Likert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.

Product handling was assessed by the subject as a single response on a 5-point Likert scale (Strongly Agree, Agree, Undecided, Disagree, Strongly Disagree) to best describe their lens wearing experience over the last 3 days. Responses were summarized by agreement category and presented as percentage of subjects.

Time frame: Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with data in each treatment group, respectively, by visit.

ArmMeasureGroupValue (NUMBER)
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Strongly Agree, n=236, 11331.4 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Agree, n=236, 11352.1 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Undecided, n=236, 11310.2 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Disagree, n=236, 1135.9 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Strongly Disagree, n=236, 1130.4 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Strongly Agree, n=234, 11227.8 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Agree, n=234, 11259.0 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Undecided, n=234, 1129.0 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Disagree, n=234, 1123.0 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Strongly Disagree, n=234, 1121.3 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Strongly Agree, n=232, 11025.0 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Agree, n=232, 11062.5 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Undecided, n=232, 1106.5 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Disagree, n=232, 1104.7 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Strongly Disagree, n=232, 1101.3 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Strongly Agree, n=229, 10928.4 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Agree, n=229, 10960.7 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Undecided, n=229, 1094.8 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Disagree, n=229, 1094.8 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Strongly Disagree, n=229, 1091.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Undecided, n=229, 1097.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Strongly Agree, n=236, 11338.1 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Strongly Agree, n=232, 11028.2 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Agree, n=236, 11347.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Strongly Agree, n=229, 10928.4 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Undecided, n=236, 1136.2 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Agree, n=232, 11051.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Disagree, n=236, 1134.4 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Strongly Disagree, n=229, 1091.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 7, Strongly Disagree, n=236, 1133.5 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Undecided, n=232, 11010.0 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Strongly Agree, n=234, 11225.0 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Agree, n=229, 10956.0 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Agree, n=234, 11259.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Disagree, n=232, 1108.2 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Undecided, n=234, 1126.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 90, Disagree, n=229, 1096.4 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Disagree, n=234, 1128.0 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 60, Strongly Disagree, n=232, 1101.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, I Like the Way This Product Feels During Handling.Day 30, Strongly Disagree, n=234, 1120.9 percentage of subjects
Primary

Likert Item - When I Use This Solution, my Lenses Are Comfortable All Day.

Lens comfort was assessed by the subject as a single response on a 5-point Likert scale (Strongly Agree, Agree, Undecided, Disagree, Strongly Disagree) to best describe their lens wearing experience over the last 3 days. Responses were summarized by agreement category and presented as percentage of subjects.

Time frame: Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with data in each treatment group, respectively, by visit.

ArmMeasureGroupValue (NUMBER)
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Strongly Agree, n=234, 11229.9 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Agree, n=232, 11054.3 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Disagree, n=236, 1138.9 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Undecided, n=232, 1106.5 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Agree, n=234, 11250.9 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Disagree, n=232, 11013.8 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Undecided, n=236, 1135.1 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Strongly Disagree, n=232, 1100.9 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Undecided, n=234, 1125.1 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Strongly Agree, n=229, 10928.8 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Disagree, n=234, 11212.0 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Agree, n=229, 10954.6 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Strongly Disagree, n=236, 1130.8 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Undecided, n=229, 1094.8 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Strongly Disagree, n=234, 1122.1 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Disagree, n=229, 10910.5 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Agree, n=236, 11355.1 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Strongly Disagree, n=229, 1091.3 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Strongly Agree, n=232, 11024.6 percentage of subjects
FID 120947ALikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Strongly Agree, n=236, 11330.1 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Undecided, n=234, 1126.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Strongly Agree, n=236, 11336.3 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Agree, n=236, 11350.4 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Undecided, n=236, 1133.5 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Disagree, n=236, 1137.1 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 7, Strongly Disagree, n=236, 1132.7 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Strongly Agree, n=234, 11224.1 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Agree, n=234, 11251.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Disagree, n=234, 11216.1 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 30, Strongly Disagree, n=234, 1121.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Strongly Agree, n=232, 11021.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Agree, n=232, 11051.8 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Undecided, n=232, 1105.5 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Disagree, n=232, 11014.5 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 60, Strongly Disagree, n=232, 1106.4 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Strongly Agree, n=229, 10923.9 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Agree, n=229, 10959.6 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Undecided, n=229, 1095.5 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Disagree, n=229, 1099.2 percentage of subjects
Renu FreshLikert Item - When I Use This Solution, my Lenses Are Comfortable All Day.Day 90, Strongly Disagree, n=229, 1091.8 percentage of subjects
Primary

Number of Unscheduled Lens Replacements by Reason

A fresh pair of lenses was dispensed on Day 0, Day 30, and Day 60. Lenses replaced at other times were considered unscheduled. The counts in the table represent the total number of unscheduled lenses replaced by reason for any eye, any subject.

Time frame: Up to Day 90

Population: This analysis population includes all randomized subjects.

ArmMeasureGroupValue (NUMBER)
FID 120947ANumber of Unscheduled Lens Replacements by ReasonLost4 lenses
FID 120947ANumber of Unscheduled Lens Replacements by ReasonLens torn while handling5 lenses
FID 120947ANumber of Unscheduled Lens Replacements by ReasonLens torn on eye2 lenses
FID 120947ANumber of Unscheduled Lens Replacements by ReasonOther9 lenses
FID 120947ANumber of Unscheduled Lens Replacements by ReasonDiscomfort3 lenses
Renu FreshNumber of Unscheduled Lens Replacements by ReasonOther7 lenses
Renu FreshNumber of Unscheduled Lens Replacements by ReasonDiscomfort0 lenses
Renu FreshNumber of Unscheduled Lens Replacements by ReasonLost0 lenses
Renu FreshNumber of Unscheduled Lens Replacements by ReasonLens torn on eye0 lenses
Renu FreshNumber of Unscheduled Lens Replacements by ReasonLens torn while handling5 lenses
Primary

Percentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line Change

Distance VA was assessed for each eye individually while reading a chart distant to the participant in dimmed room illumination. VA was measured using a Snellen chart, with 20/20 Snellen acuity considered normal distance-eyesight. A line increase indicates an improvement in VA. One eye (study eye) contributed to the analysis.

Time frame: Baseline (Day 0), Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with data in each treatment group, respectively, by visit.

ArmMeasureGroupValue (NUMBER)
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, 2 Line Increase from Baseline, n=236, 1120.0 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, 1 Line Increase from Baseline, n=236, 1120.4 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, No Change from Baseline, n=236, 11297.0 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, 1 Line Decrease from Baseline, n=236, 1122.5 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, 2 Line Decrease, n=236, 1120.0 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, 2 Line Increase from Baseline, n=234, 1120.0 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, 1 Line Increase from Baseline, n=234, 1122.1 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, No Change from Baseline, n=234, 11295.7 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, 1 Line Decrease from Baseline, n=234, 1122.1 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, 2 Line Decrease from Baseline, n=234, 1120.0 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, 2 Line Increase from Baseline, n=232, 1100.0 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, 1 Line Increase from Baseline, n=232, 1101.7 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, No Change from Baseline, n=232, 11095.7 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, 1 Line Decrease from Baseline, n=232, 1102.6 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, 2 Line Decrease from Baseline, n=232, 1100.0 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, 2 Line Increase from Baseline, n=229, 1090.0 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, 1 Line Increase from Baseline, n=229, 1092.2 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, No Change from Baseline, n=229, 10994.3 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, 1 Line Decrease from Baseline, n=229, 1093.1 percentage of subjects
FID 120947APercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, 2 Line Decrease from Baseline, n=229, 1090.4 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, No Change from Baseline, n=229, 10998.2 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, 2 Line Increase from Baseline, n=236, 1120.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, 2 Line Increase from Baseline, n=232, 1100.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, 1 Line Increase from Baseline, n=236, 1120.9 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, 2 Line Increase from Baseline, n=229, 1090.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, No Change from Baseline, n=236, 11299.1 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, 1 Line Increase from Baseline, n=232, 1100.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, 1 Line Decrease from Baseline, n=236, 1120.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, 2 Line Decrease from Baseline, n=229, 1090.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 7, 2 Line Decrease, n=236, 1120.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, No Change from Baseline, n=232, 11098.2 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, 2 Line Increase from Baseline, n=234, 1120.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, 1 Line Increase from Baseline, n=229, 1090.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, 1 Line Increase from Baseline, n=234, 1120.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, 1 Line Decrease from Baseline, n=232, 1101.8 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, No Change from Baseline, n=234, 11299.1 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 90, 1 Line Decrease from Baseline, n=229, 1091.8 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, 1 Line Decrease from Baseline, n=234, 1120.9 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 60, 2 Line Decrease from Baseline, n=232, 1100.0 percentage of subjects
Renu FreshPercentage of Subjects With Change From Baseline in Contact Lens-Corrected Distance Visual Acuity (CLCDVA) by Line ChangeDay 30, 2 Line Decrease from Baseline, n=234, 1120.0 percentage of subjects
Primary

Percentage of Subjects With Crystalline Deposits by Type

Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered: Type II = films or deposits visible only under special conditions, such as special illumination using an eyepiece of 7-10 times magnification, Type III = films or deposits readily visible on a dry lens under room lighting, with unaided eye, and Type IV = films or deposits obvious under room lighting, with unaided eye, when the lens is wet or dry. One eye (study eye) contributed to the analysis.

Time frame: Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with crystalline deposits in each treatment group, respectively, by visit.

ArmMeasureGroupValue (NUMBER)
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 7, Type II, n=55,3263.6 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 7, Type III, n=55,3225.5 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 7, Type IV, n=55,3210.9 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 30, Type II, n=74, 3770.3 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 30, Type III, n=74, 3710.8 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 30, Type IV, n=74, 3718.9 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 60, Type II, n=73, 3663.0 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 60, Type III, n=73, 3613.7 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 60, Type IV, n=73, 3623.3 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 90, Type II, n=69, 4260.9 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 90, Type III, n=69, 4218.8 percentage of subjects
FID 120947APercentage of Subjects With Crystalline Deposits by TypeDay 90, Type IV, n=69, 4220.3 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 90, Type II, n=69, 4259.5 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 7, Type II, n=55,3265.6 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 90, Type IV, n=69, 4221.4 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 7, Type III, n=55,3225.0 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 60, Type III, n=73, 3625.0 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 7, Type IV, n=55,329.4 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 90, Type III, n=69, 4219.0 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 30, Type II, n=74, 3759.5 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 60, Type IV, n=73, 3633.3 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 30, Type III, n=74, 3716.2 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 60, Type II, n=73, 3641.7 percentage of subjects
Renu FreshPercentage of Subjects With Crystalline Deposits by TypeDay 30, Type IV, n=74, 3724.3 percentage of subjects
Primary

Percentage of Subjects With Film Deposits by Type

Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered: Type II = films or deposits visible only under special conditions, such as special illumination using an eyepiece of 7-10 times magnification, Type III = films or deposits readily visible on a dry lens under room lighting, with unaided eye, and Type IV = films or deposits obvious under room lighting, with unaided eye, when the lens is wet or dry. One eye (study eye) contributed to the analysis.

Time frame: Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with film deposits in each treatment group, respectively, by visit.

ArmMeasureGroupValue (NUMBER)
FID 120947APercentage of Subjects With Film Deposits by TypeDay 7, Type II, n=114, 5657.0 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 7, Type III, n=114, 5616.7 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 7, Type IV, n=114, 5626.3 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 30, Type II, n=125, 6662.4 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 30, Type III, n=125, 6614.4 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 30, Type IV, n=125, 6623.2 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 60, Type II, n=114, 6363.2 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 60, Type III, n=114, 638.8 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 60, Type IV, n=114, 6328.1 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 90, Type II, n=114, 5964.9 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 90, Type III, n=114, 5910.5 percentage of subjects
FID 120947APercentage of Subjects With Film Deposits by TypeDay 90, Type IV, n=114, 5924.6 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 90, Type III, n=114, 5913.6 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 7, Type II, n=114, 5658.9 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 60, Type II, n=114, 6355.6 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 7, Type III, n=114, 5619.6 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 90, Type II, n=114, 5950.8 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 7, Type IV, n=114, 5621.4 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 60, Type III, n=114, 637.9 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 30, Type II, n=125, 6662.1 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 90, Type IV, n=114, 5935.6 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 30, Type III, n=125, 6613.6 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 60, Type IV, n=114, 6336.5 percentage of subjects
Renu FreshPercentage of Subjects With Film Deposits by TypeDay 30, Type IV, n=125, 6624.2 percentage of subjects
Primary

Percentage of Subjects With Visibly Clean Lenses

Worn study lenses were removed and evaluated for deposits. Deposits found on the lenses were defined using a 3-part classification system consisting of general visibility, the specific appearance and area covered. A lens was considered visibly clean if it had nondetectable films or deposits. One eye (study eye) contributed to the analysis.

Time frame: Day 7, Day 30, Day 60, Day 90

Population: This analysis population includes all randomized subjects. Here, n is the total number of subjects with data in each treatment group, respectively, by visit.

ArmMeasureGroupValue (NUMBER)
FID 120947APercentage of Subjects With Visibly Clean LensesDay 7, n=236, 11344.5 percentage of subjects
FID 120947APercentage of Subjects With Visibly Clean LensesDay 30, n=234, 11235.0 percentage of subjects
FID 120947APercentage of Subjects With Visibly Clean LensesDay 60, n=232, 11040.5 percentage of subjects
FID 120947APercentage of Subjects With Visibly Clean LensesDay 90, n=229, 10941.9 percentage of subjects
Renu FreshPercentage of Subjects With Visibly Clean LensesDay 90, n=229, 10933.0 percentage of subjects
Renu FreshPercentage of Subjects With Visibly Clean LensesDay 7, n=236, 11339.8 percentage of subjects
Renu FreshPercentage of Subjects With Visibly Clean LensesDay 60, n=232, 11032.7 percentage of subjects
Renu FreshPercentage of Subjects With Visibly Clean LensesDay 30, n=234, 11231.3 percentage of subjects