Radioaerossol Pulmonary Deposition Using Mesh in Normal Subjects

RADIOAEROSSOL PULMONARY DEPOSiTION USING MESH AND JET NEBULIZERS DURING NONINVASIVE VENTILATION IN NORMAL SUBJECTS: A RANDOMIZED CROSSOVER CLINICAL TRIAL

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01889524
Enrollment
10
Registered
2013-06-28
Start date
2012-01-31
Completion date
2012-04-30
Last updated
2013-06-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Normal Subjects

Brief summary

In vivo deposition studies of aerosol administration during noninvasive ventilation are scarce in the current literature. We assessed 10 normal subjects in a crossover study evaluated by pulmonary scintigraphy aiming to compare radiaoaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) of radiotagged aerosol administered using vibrating mesh nebulizers (VMN) and conventional jet nebulizer (JN) during noninvasive ventilation (NIV).

Interventions

OTHERMesh nebulizer

VMN (NIVO, Respironics®, Murrysville, Pennsylvania, USA) with an MMAD of 3.0 µm was placed in the elbow adapter at the mask. Inhalation was performed using diethilene triamine penta-acetic technetium (99mTc-DTPA) with radioactivity of 25 millicuries (Nobre et al., 2007). Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and normal saline solution to complete a fill volume of 3 mL.

The JN (Misty Max, Air Life, Yorba Linda, USA) with a particle MMAD of 5 µm (according to the manufacturer information) was positioned in the circuit using a T piece placed between the circuit leak and the mask, and operated with oxygen flow at 8 L/min. Inhalation was performed using diethilene triamine penta-acetic technetium (99mTc-DTPA) with radioactivity of 25 millicuries (Nobre et al., 2007). Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and normal saline solution to complete a fill volume of 3 mL.

OTHERNoninvasive ventilation-NIV

Bilevel positive airway pressure (BiPAP Synchrony, Respironics®, Murrysville, Pennsylvania, USA) was applied through face mask (Comfort Full 2, Respironics®, Murrysville, Pennsylvania, USA) attached with straps and pressure adjusted to12 cmH2O peak inspiratory pressure and 5 cmH2O of expiratory pressure at the beginning of the procedure. Patients were adapted to use NIV before starting measurements, pressures were titrated before reaching the established levels and just after this period masks were fitted using the straps. They were oriented to use a breathing pattern inspiring deeply and exhaling slowing to avoid ventilator-patient asynchrony.

Sponsors

Georgia State University
CollaboratorOTHER
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
CollaboratorOTHER_GOV
Conselho Nacional de Desenvolvimento Científico e Tecnológico
CollaboratorOTHER_GOV
Universidade Federal de Pernambuco
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* No history of lung disease; * Forced vital capacity (FVC) or forced expiratory volume in the first second (FEV1) higher or equal to 80% from predicted values (Pereira et al., 1992), * No history of smoking; * Without respiratory or cardiovascular disease; * Ability to understand verbal commands; * Willing to provide signed consent to participate in this study.

Exclusion criteria

* Pregnant; * Were unable to tolerate NIV (Metha and Hill, 2001).

Design outcomes

Primary

MeasureTime frameDescription
Radioaerosol deposition index4 mInhalation was performed using diethilene triamine penta-acetic technetium (99mTc-DTPA) with radioactivity of 25 millicuries (Nobre et al., 2007). Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and normal saline solution to complete a fill volume of 3 mL. The JN (Misty Max, Air Life, Yorba Linda, USA) with a particle MMAD of 5 µm (according to the manufacturer information) was positioned in the circuit using a T piece placed between the circuit leak and the mask, and operated with oxygen flow at 8 L/min. VMN (NIVO, Respironics®, Murrysville, Pennsylvania, USA) with an MMAD of 3.0 µm was placed in the elbow adapter at the mask.

Secondary

MeasureTime frameDescription
Radioaerosol mass balance in pulmonary and extrapulmonary compartments4 mthe same procedure was performed to analysis deposition in the nebulizer, circuits, inspiratory filter, expiratory filter and face mask. Counts representing stomach were obtained from posterior thorax and corrections for decay of technetium were used during extrapulmonary measurements. The analysis of deposition in pulmonary and extrapulmonary compartments was expressed as a percentage from the cumulative count in each compartment representing the total radioaerosol mass.

Countries

Brazil

Outcome results

None listed